Improved external device for a mass-carrying sliding system for shaking table testing

被引:15
|
作者
Carrillo, Julian [1 ,2 ]
Alcocer, Sergio [2 ]
机构
[1] Univ Militar Nueva Granada, Dept Ingn Civil, Bogota, Colombia
[2] Univ Nacl Autonoma Mexico, Inst Ingn, Coyoacan 04510, DF, Mexico
来源
关键词
dynamic response; mass; shaking table testing; structural models; test equipment;
D O I
10.1002/eqe.1026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Shaking tables are suitable facilities to assess and validate the behavior of structures and nonstructural components under actual seismic actions. Because of the size and weight limitations of the tables, some approaches, like testing reduced-scale models or testing only the main structural components, are deemed necessary. In these cases, to comply with modeling requirements, large amount of extra-mass should be added to the specimen. Therefore, to avoid the risk of lateral instability of models, to maintain the weight of test specimens within table payload, while maintaining the amount of mass needed, an external device for transmitting the inertia forces to the models using an improved sliding system is proposed. Although friction devices for similar purposes have been developed using sliding bearings (Teflon pads or rollers), the measured coefficient of dynamic friction and the energy dissipated by friction have been very high. In order to drastically diminish the damping added to the specimen response when a friction device is used, the improved device employs a linear motion guide system (LMGS) with very low friction. Shaking table tests to collapse of reinforced concrete walls were used to evaluate the effectiveness of the proposed device. Measured dynamic friction coefficients, spectral accelerations and hysteresis loops show that friction developed in the LMGS did not add any significant amount of damping into the specimen response. Thus, the proposed device is a reliable and suitable mass-carrying sliding system (MCSS) for dynamic testing using medium-size shaking tables. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:393 / 411
页数:19
相关论文
共 31 条
  • [21] Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device
    King, Brian W.
    Morf, Daniel
    Greer, Peter B.
    MEDICAL PHYSICS, 2012, 39 (05) : 2839 - 2847
  • [22] Data-Driven Two-Level Performance Evaluation of Eddy-Current Tuned Mass Damper for Building Structures Using Shaking Table and Field Testing
    Lu, Xilin
    Zhang, Qi
    Wu, Weichao
    Shan, Jiazeng
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2019, 34 (01) : 38 - 57
  • [23] IMAGE-BASED MONITORING SYSTEM FOR CONCEALED SUSPENDED PIPING IN BUILDINGS Verification in shaking table testing of a full-scale steel frame with hospital functionality
    Sakakibara, Yurie
    Kawamata, Yohsuke
    Fujita, Kohei
    Kurata, Masahiro
    Journal of Structural and Construction Engineering, 2022, 87 (798): : 725 - 736
  • [24] Tracking control of an electro-hydraulic shaking table system using a combined feedforward inverse model and adaptive inverse control for real-time testing
    Shen, G.
    Zheng, S. T.
    Ye, Z. M.
    Yang, Z. D.
    Zhao, Y.
    Han, J. W.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2011, 225 (I5) : 647 - 666
  • [25] Experimental study and numerical modeling of nonlinear dynamic response of SDOF system equipped with tuned mass damper inerter (TMDI) tested on shaking table under harmonic excitation
    Pietrosanti, Daniele
    De Angelis, Maurizio
    Giaralis, Agathoklis
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2020, 184
  • [26] Optimal Switching Table-Based Sliding Mode Control of an Energy Recovery Li-Ion Power Accumulator Battery Pack Testing System
    Long, Bo
    Ryu, Ji Hyoung
    Chong, Kil To
    ENERGIES, 2013, 6 (10): : 5200 - 5218
  • [27] Shaking-table tests of a full-scale ten-story reinforced-concrete building (FY2015). Phase I: Free-standing system with base sliding and uplifting
    Kajiwara, Koichi
    Tosauchi, Yusuke
    Kang, Jae-Do
    Fukuyama, Kunio
    Sato, Eiji
    Inoue, Takahito
    Kabeyasawa, Toshimi
    Shiohara, Hitoshi
    Nagae, Takuya
    Kabeyasawa, Toshikazu
    Fukuyama, Hiroshi
    Mukai, Tomohisa
    ENGINEERING STRUCTURES, 2021, 233
  • [28] Seismic performance of controlled rocklng frames with shear fuse and PT wire anchorage: Shaking table tests on controlled rocking steel frames using multipurpose inertial mass system part i
    Midorikawa M.
    Takeuchi T.
    Hikino T.
    Kasai K.
    Deierlein G.
    Ohbayashi M.
    Yammaki R.
    Kiyhm S.
    Journal of Structural and Construction Engineering, 2010, 75 (654): : 1547 - 1556
  • [29] The World Health Organization's External Quality Assurance System proficiency testing program has improved the accuracy of antimicrobial susceptibility testing and reporting among participating laboratories using NCCLS methods
    Chaitram, JM
    Jevitt, LA
    Lary, S
    Tenover, FC
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) : 2372 - 2377
  • [30] Real-time hybrid testing for active mass driver system based on an improved control strategy against control-structure-interaction effects
    Yao, Hongcan
    Tan, Ping
    Zhou, Huimeng
    Zhou, Fulin
    JOURNAL OF BUILDING ENGINEERING, 2023, 63