Improving MR Image Quality in Patients with Metallic Implants

被引:32
|
作者
Lee, Elizabeth M. [1 ]
Ibrahim, El-Sayed H. [7 ]
Dudek, Nancy [2 ]
Lu, Jimmy C. [3 ]
Kalia, Vivek [4 ]
Runge, Mason [5 ]
Srinivasan, Ashok [6 ]
Stojanovska, Jadranka [1 ]
Agarwal, Prachi P. [1 ]
机构
[1] Univ Michigan, Dept Radiol, Div Cardiothorac Imaging, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Radiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Div Cardiol, CS Mott Childrens Hosp, Dept Pediat, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Radiol, Div Musculoskeletal Radiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[5] Univ Michigan, Med Sch, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Dept Radiol, Div Neuroradiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[7] Med Coll Wisconsin, Ctr Imaging Res, Milwaukee, WI 53226 USA
关键词
MAGNETIC-RESONANCE; ARTIFACT REDUCTION; CARDIOVERTER-DEFIBRILLATORS; VENTRICULAR-TACHYCARDIA; CATHETER ABLATION; HIP-ARTHROPLASTY; SEQUENCE; SUPPRESSION; PACEMAKERS; PROTOCOL;
D O I
10.1148/rg.2021200092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The number of implanted devices such as orthopedic hardware and cardiac implantable devices continues to increase with an increase in the age of the patient population, as well as an increase in the number of indications for specific devices. Many patients with these devices have or will develop clinical conditions that are best depicted at MRI. However, implanted devices containing paramagnetic or ferromagnetic substances can cause significant artifact, which could limit the diagnostic capability of this modality. Performing imaging with MRI when an implant is present may be challenging, and there are numerous techniques the radiologist and technologist can use to help minimize artifacts related to implants. First, knowledge of the presence of an implant before patient arrival is critical to ensure safety of the patient when the device is subjected to a strong magnetic field. Once safety is ensured, the examination should be performed with the MRI system that is expected to provide the best image quality. The selection of the MRI system includes multiple considerations such as the effects of field strength and availability of specific sequences, which can reduce metal artifact. Appropriate patient positioning, attention to MRI parameters (including bandwidth, voxel size, and echo), and appropriate selection of sequences (those with less metal artifact and advanced metal reduction sequences) are critical to improve image quality. Patients with implants can be successfully imaged with MRI with appropriate planning and understanding of how to minimize artifacts. This improves image quality and the diagnostic confidence of the radiologist. (C) RSNA, 2021
引用
收藏
页码:E126 / E137
页数:12
相关论文
共 50 条
  • [41] Metallic dental artifact reduction in computed tomography (Smart MAR): Improvement of image quality and diagnostic confidence in patients with suspected head and neck pathology and oral implants
    Feldhaus, Felix
    Boening, Georg
    Jonczyk, Martin
    Kahn, Johannes
    Fehrenbach, Uli
    Maurerb, M.
    Benz, D.
    Hamm, Bernd
    Streitparth, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 : 153 - 160
  • [42] Post-ACDF imaging in patients with metallic implants
    Chang, Chih-Chang
    Wu, Ching-Lan
    Wu, Jau-Ching
    Chang, Hsuan-Kan
    Fay, Li-Yu
    Tu, Tsung-Hsi
    Huang, Wen-Cheng
    Cheng, Henrich
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (03) : 418 - 419
  • [43] Contrast degradation for improving quality of an image
    Inampudi, RB
    Purimetla, TN
    Satyanarayana, PG
    IGARSS 2002: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM AND 24TH CANADIAN SYMPOSIUM ON REMOTE SENSING, VOLS I-VI, PROCEEDINGS: REMOTE SENSING: INTEGRATING OUR VIEW OF THE PLANET, 2002, : 3408 - 3410
  • [44] Improving Image Quality of Tiled Displays
    McFadden, Steven B.
    Ward, Paul A. S.
    IMAGE ANALYSIS AND RECOGNITION (ICIAR 2015), 2015, 9164 : 22 - 29
  • [45] IMPROVING IMAGE QUALITY IN FIBER ENDOSCOPES
    VEYNBERG, VB
    KHARCHENKO, NI
    KUZMINA, NP
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1977, 44 (08): : 458 - 461
  • [46] MR IMAGING AND METALLIC IMPLANTS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - ASSESSMENT OF FERROMAGNETISM AND ARTIFACT
    SHELLOCK, FG
    MINK, JH
    CURTIN, S
    FRIEDMAN, MJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 225 - 228
  • [47] Improving image quality for JPEG compression
    Chang, CC
    Chou, YC
    Shen, JJ
    KNOWLEDGE-BASED INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, PT 3, PROCEEDINGS, 2005, 3683 : 442 - 448
  • [48] New MR Imaging Methods for Metallic Implants in the Knee: Artifact Correction and Clinical Impact
    Chen, Christina A.
    Chen, Weitian
    Goodman, Stuart B.
    Hargreaves, Brian A.
    Koch, Kevin M.
    Lu, Wenmaio
    Brau, Anja C.
    Draper, Christine E.
    Delp, Scott L.
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1121 - 1127
  • [49] Improvement of image quality in MR cholangiography.
    Obenauer, S
    Fischer, U
    Heuser, M
    Wilke, R
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (06): : 450 - 454
  • [50] Optimising MR image quality of the canine nose
    Wolf, Davina
    Luepke, Matthias
    Wefstaedt, Patrick
    Melichar, Kerstin
    Nolte, Ingo
    Seifert, Hermann
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2009, 122 (5-6): : 219 - 226