Improving MR Image Quality in Patients with Metallic Implants

被引:32
|
作者
Lee, Elizabeth M. [1 ]
Ibrahim, El-Sayed H. [7 ]
Dudek, Nancy [2 ]
Lu, Jimmy C. [3 ]
Kalia, Vivek [4 ]
Runge, Mason [5 ]
Srinivasan, Ashok [6 ]
Stojanovska, Jadranka [1 ]
Agarwal, Prachi P. [1 ]
机构
[1] Univ Michigan, Dept Radiol, Div Cardiothorac Imaging, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Radiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Div Cardiol, CS Mott Childrens Hosp, Dept Pediat, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Radiol, Div Musculoskeletal Radiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[5] Univ Michigan, Med Sch, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Dept Radiol, Div Neuroradiol, Univ Hosp Floor B1 Recept C,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[7] Med Coll Wisconsin, Ctr Imaging Res, Milwaukee, WI 53226 USA
关键词
MAGNETIC-RESONANCE; ARTIFACT REDUCTION; CARDIOVERTER-DEFIBRILLATORS; VENTRICULAR-TACHYCARDIA; CATHETER ABLATION; HIP-ARTHROPLASTY; SEQUENCE; SUPPRESSION; PACEMAKERS; PROTOCOL;
D O I
10.1148/rg.2021200092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The number of implanted devices such as orthopedic hardware and cardiac implantable devices continues to increase with an increase in the age of the patient population, as well as an increase in the number of indications for specific devices. Many patients with these devices have or will develop clinical conditions that are best depicted at MRI. However, implanted devices containing paramagnetic or ferromagnetic substances can cause significant artifact, which could limit the diagnostic capability of this modality. Performing imaging with MRI when an implant is present may be challenging, and there are numerous techniques the radiologist and technologist can use to help minimize artifacts related to implants. First, knowledge of the presence of an implant before patient arrival is critical to ensure safety of the patient when the device is subjected to a strong magnetic field. Once safety is ensured, the examination should be performed with the MRI system that is expected to provide the best image quality. The selection of the MRI system includes multiple considerations such as the effects of field strength and availability of specific sequences, which can reduce metal artifact. Appropriate patient positioning, attention to MRI parameters (including bandwidth, voxel size, and echo), and appropriate selection of sequences (those with less metal artifact and advanced metal reduction sequences) are critical to improve image quality. Patients with implants can be successfully imaged with MRI with appropriate planning and understanding of how to minimize artifacts. This improves image quality and the diagnostic confidence of the radiologist. (C) RSNA, 2021
引用
收藏
页码:E126 / E137
页数:12
相关论文
共 50 条
  • [1] MR IMAGING IN PATIENTS WITH METALLIC IMPLANTS
    LAAKMAN, RW
    KAUFMAN, B
    HAN, JS
    NELSON, AD
    CLAMPITT, M
    OBLOCK, AM
    HAAGA, JR
    ALFIDI, RJ
    RADIOLOGY, 1985, 157 (03) : 711 - 714
  • [2] MR is safe in patients with metallic stapes implants
    不详
    CLINICAL OTOLARYNGOLOGY, 2006, 31 (06) : 488 - 488
  • [3] Improved MR imaging for patients with metallic implants
    Viano, AM
    Gronemeyer, SA
    Haliloglu, M
    Hoffer, FA
    MAGNETIC RESONANCE IMAGING, 2000, 18 (03) : 287 - 295
  • [4] Improving Prostate MR Image Quality in Practice-Initial Results From the ACR Prostate MR Image Quality Improvement Collaborative
    Purysko, Andrei S.
    Zacharias-Andrews, Kay
    Tomkins, Kandice Garcia
    Turkbey, Ismail Baris
    Giganti, Francesco
    Bhargavan-Chatfield, Mythreyi
    Larson, David B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (09) : 1464 - 1474
  • [5] Improving biocompatibility for next generation of metallic implants
    Bandyopadhyay, Amit
    Mitra, Indranath
    Goodman, Stuart B.
    Kumar, Mukesh
    Bose, Susmita
    PROGRESS IN MATERIALS SCIENCE, 2023, 133
  • [6] IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS
    HAACKE, EM
    LENZ, GW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) : 1251 - 1258
  • [7] MR IMAGING OF METALLIC IMPLANTS AND MATERIALS - A COMPILATION OF THE LITERATURE
    SHELLOCK, FG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) : 811 - 814
  • [8] CRANIO-ORBITAL RECONSTRUCTION - SAFETY AND IMAGE QUALITY OF METALLIC IMPLANTS ON CT AND MRI SCANNING
    SULLIVAN, PK
    SMITH, JF
    ROZZELLE, AA
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 94 (05) : 589 - 596
  • [9] THE VALUE OF PUBLISHED DATA ON MR COMPATIBILITY OF METALLIC IMPLANTS AND DEVICES
    KANAL, E
    SHELLOCK, FG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (07) : 1394 - 1396
  • [10] MR-IMAGING ARTIFACTS CAUSED BY ABRASION OF METALLIC IMPLANTS
    WEYRICH, G
    SIGMUND, G
    SCHLICKEWEI, W
    VINEE, P
    RADIOLOGE, 1993, 33 (06): : 367 - 371