Energy performance analysis of a novel solar PVT loop heat pipe employing a microchannel heat pipe evaporator and a PCM triple heat exchanger

被引:108
|
作者
Diallo, Thierno M. O. [1 ]
Yu, Min [1 ]
Zhou, Jinzhi [1 ]
Zhao, Xudong [1 ]
Shittu, Samson [1 ]
Li, Guiqiang [1 ]
Ji, Jie [2 ]
Hardy, David [1 ]
机构
[1] Univ Hull, Sch Engn, Kingston Upon Hull, N Humberside, England
[2] Univ Sci & Technol China, Hefei, Peoples R China
基金
“创新英国”项目; 英国工程与自然科学研究理事会;
关键词
PVT; Loop heat pipe; Microchannel; PCM triple heat exchanger; Heating; Power supply; THERMAL PERFORMANCE; COLLECTOR; SYSTEM; FLOW;
D O I
10.1016/j.energy.2018.10.192
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents a numerical analysis of the energy efficiency for a novel solar PVT Loop Heat Pipe (PVT-LHP) employing a novel Micro-channel evaporator and a novel PCM heat storage exchanger. It presents a description of the different sub-models in the PVT-LHP system (the PVT model, the micro-channel heat collector model and the novel PCM triple heat exchanger model) and the integrated model of the system. The integrated model of the system was solved by ensuring a heat balance at the condenser and the evaporator. A parametric analysis has been performed in order to assess the influence of the environmental parameters (i.e. solar radiation, air temperature, wind velocity), structural parameters (i.e. glazing cover, the number of absorbing microchannel heat pipes, PV cell packing factor), the circulating fluid variables (i.e. cold-water inlet temperature and water mass flow rate) on the energy performance of the system. The novel PVT-LHP has been compared with a conventional Solar PVT-LHP system. It was found that lower solar radiation, lower ambient air temperature, higher wind speed, higher packing factor, lower cold-water inlet temperature and a smaller cover number led to an enhanced electrical efficiency, but a reduced thermal efficiency of the module; whereas a higher cold water mass flow rate and a greater number of microchannel heat pipes gave rise to both thermal and electrical efficiencies of the module. It was also found that an increase of solar radiation, ambient temperature, cover number, microchannel heat pipe number and packing factor are favourable factors for the overall COP (Coefficient Of Performance) of the system, whereas an increase of wind velocity and cold water mass flow rate are unfavourable. The study indicated the existence of an optimal cover number, number of microchannel heat pipes and mass flowrate. Under the given design conditions, the electrical, thermal and overall efficiency of the PV/LHP module were 12.2%, 55.6% and 67.8% respectively and the novel system can achieve 28% higher overall energy efficiency and 2.2 times higher COP compared to a conventional system. The integrated computer model developed in this study can be used to design and optimize the novel PVT-LHP heating system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:866 / 888
页数:23
相关论文
共 50 条
  • [21] Numerical investigation of the performance of a triple concentric pipe heat exchanger
    Quadir, G. A.
    Badruddin, Irfan Anjum
    Ahmed, Salman N. J.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 75 : 165 - 172
  • [22] Dynamic performance of a novel solar photovoltaic/loop-heat-pipe heat pump system
    Zhang, Xingxing
    Zhao, Xudong
    Shen, Jingchun
    Xu, Jihuan
    Yu, Xiaotong
    [J]. APPLIED ENERGY, 2014, 114 : 335 - 352
  • [23] Thermal performance analysis of heat pipe heat exchanger for effective waste heat recovery
    Geum, Gyohoon
    Kang, Sukkyung
    Cho, Sehyeon
    Kong, Daeyoung
    Lee, Seungjae
    Seo, JinHyeuk
    Shin, Dong Hwan
    Lee, Seong Hyuk
    Lee, Jungho
    Lee, Hyoungsoon
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 151
  • [24] Novel design of a miniature loop heat pipe evaporator for electronic cooling
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Dixon, Chris
    Mochizuki, Masataka
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2007, 129 (10): : 1445 - 1452
  • [25] Investigation of instability on loop heat pipe with flat evaporator
    Gai, Dongxing
    Yin, Yang
    Chen, Chen
    [J]. FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [27] Transient responses of the flat evaporator loop heat pipe
    Joung, Wukchul
    Gam, Keesool
    Park, Kwangmin
    Ma, Sungpil
    Lee, Jinho
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 57 (01) : 131 - 141
  • [28] Research and development of loop heat pipe with flat evaporator
    Xiong, Kangning
    Wu, Wei
    Wang, Shuangfeng
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (10): : 5388 - 5402
  • [29] Transient properties of bifacial evaporator loop heat pipe
    He, Song
    Liu, Zhichun
    Wang, Dongdong
    Liu, Wei
    Yang, Jinguo
    Zhang, Xiaoyu
    [J]. Huagong Xuebao/CIESC Journal, 2016, 67 (05): : 1778 - 1783
  • [30] Thermodynamic comparison of two novel combined systems based on solar loop heat pipe evaporator
    Beygzadeh, V
    Khalilarya, Sh
    Mirzaee, I
    [J]. ENERGY, 2020, 206