Energy performance analysis of a novel solar PVT loop heat pipe employing a microchannel heat pipe evaporator and a PCM triple heat exchanger

被引:108
|
作者
Diallo, Thierno M. O. [1 ]
Yu, Min [1 ]
Zhou, Jinzhi [1 ]
Zhao, Xudong [1 ]
Shittu, Samson [1 ]
Li, Guiqiang [1 ]
Ji, Jie [2 ]
Hardy, David [1 ]
机构
[1] Univ Hull, Sch Engn, Kingston Upon Hull, N Humberside, England
[2] Univ Sci & Technol China, Hefei, Peoples R China
基金
英国工程与自然科学研究理事会; “创新英国”项目;
关键词
PVT; Loop heat pipe; Microchannel; PCM triple heat exchanger; Heating; Power supply; THERMAL PERFORMANCE; COLLECTOR; SYSTEM; FLOW;
D O I
10.1016/j.energy.2018.10.192
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents a numerical analysis of the energy efficiency for a novel solar PVT Loop Heat Pipe (PVT-LHP) employing a novel Micro-channel evaporator and a novel PCM heat storage exchanger. It presents a description of the different sub-models in the PVT-LHP system (the PVT model, the micro-channel heat collector model and the novel PCM triple heat exchanger model) and the integrated model of the system. The integrated model of the system was solved by ensuring a heat balance at the condenser and the evaporator. A parametric analysis has been performed in order to assess the influence of the environmental parameters (i.e. solar radiation, air temperature, wind velocity), structural parameters (i.e. glazing cover, the number of absorbing microchannel heat pipes, PV cell packing factor), the circulating fluid variables (i.e. cold-water inlet temperature and water mass flow rate) on the energy performance of the system. The novel PVT-LHP has been compared with a conventional Solar PVT-LHP system. It was found that lower solar radiation, lower ambient air temperature, higher wind speed, higher packing factor, lower cold-water inlet temperature and a smaller cover number led to an enhanced electrical efficiency, but a reduced thermal efficiency of the module; whereas a higher cold water mass flow rate and a greater number of microchannel heat pipes gave rise to both thermal and electrical efficiencies of the module. It was also found that an increase of solar radiation, ambient temperature, cover number, microchannel heat pipe number and packing factor are favourable factors for the overall COP (Coefficient Of Performance) of the system, whereas an increase of wind velocity and cold water mass flow rate are unfavourable. The study indicated the existence of an optimal cover number, number of microchannel heat pipes and mass flowrate. Under the given design conditions, the electrical, thermal and overall efficiency of the PV/LHP module were 12.2%, 55.6% and 67.8% respectively and the novel system can achieve 28% higher overall energy efficiency and 2.2 times higher COP compared to a conventional system. The integrated computer model developed in this study can be used to design and optimize the novel PVT-LHP heating system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:866 / 888
页数:23
相关论文
共 50 条
  • [1] INVESTIGATION OF HEAT TRANSFER IN EVAPORATOR OF MICROCHANNEL LOOP HEAT PIPE
    Yakomaskin, Alexander A.
    Afanasiev, Valery N.
    Zubkov, Nikolay N.
    Morskoy, Dmitry N.
    [J]. PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 539 - 546
  • [2] Investigation of Heat Transfer in Evaporator of Microchannel Loop Heat Pipe
    Yakomaskin, Alexander A.
    Afanasiev, Valery N.
    Zubkov, Nikolay N.
    Morskoy, Dmitry N.
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2013, 135 (10):
  • [3] Evaporative cooling experiment of microchannel heat exchanger in loop heat pipe
    Liu, Haichao
    Shao, Shuangquan
    Zhang, Hainan
    Tian, Changqing
    [J]. Huagong Xuebao/CIESC Journal, 2018, 69 : 161 - 166
  • [4] Heat and Mass Transfer in Evaporator of Loop Heat Pipe
    Chernysheva, M. A.
    Maydanik, Y. F.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2009, 23 (04) : 725 - 731
  • [5] PERFORMANCE OF A FLEXIBLE EVAPORATOR FOR LOOP HEAT PIPE APPLICATIONS
    Limaye, Mukta S.
    Klausner, James F.
    [J]. HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2008, VOL 2, 2009, : 353 - 361
  • [6] Theoretical analysis of steady-state performance of a loop heat pipe with a novel evaporator
    Bai, Lizhan
    Lin, Guiping
    Mu, Zuodong
    Wen, Dongsheng
    [J]. APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 233 - 241
  • [7] Study on heat transfer performance for loop heat pipe with circular flat evaporator
    Nguyen, Xuan Hung
    Sung, Byung Ho
    Choi, Jeehoon
    Ryoo, Seong Ryoul
    Ko, Han Seo
    Kim, Chulju
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (04) : 1304 - 1315
  • [8] Heat Transfer Performance Analysis and Simulation of Heat Pipe Heat Exchanger
    Kwon, Hyuk Su
    Kwon, Cheong Hoon
    Jung, Eui Guk
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2023, 47 (11) : 595 - 605
  • [9] Analytical Investigation of the Heat-Transfer Limits of a Novel Solar Loop-Heat Pipe Employing a Mini-Channel Evaporator
    Diallo, Thierno M. O.
    Yu, Min
    Zhou, Jinzhi
    Zhao, Xudong
    Ji, Jie
    Hardy, David
    [J]. ENERGIES, 2018, 11 (01):
  • [10] Flat plate loop heat pipe with a novel evaporator structure
    Tsai, MC
    Yu, CS
    Kang, SW
    [J]. TWENTY-FIRST ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2005, 2005, : 187 - 190