RAPID Aneurysm: Artificial intelligence for unruptured cerebral aneurysm detection on CT angiography

被引:8
|
作者
Heit, Jeremy J. [1 ,6 ]
Honce, Justin M. [2 ]
Yedavalli, Vivek S. [3 ]
Baccin, Carlos E. [4 ]
Tatit, Rafael T. [4 ]
Copeland, Karen [5 ]
Timpone, Vincent M. [2 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA USA
[2] Univ Colorado, Sch Med, Dept Radiol, Denver, CO USA
[3] Johns Hopkins Med Sch, Dept Radiol, Baltimore, MD USA
[4] Albert Ein stein Hosp, Dept Radiol, Sa Paulo, Brazil
[5] Boulder Stat, Boulder, CO USA
[6] Stanford Sch Med, Radiol & Neurosurg, 453 Quarry Rd, Palo Alto, CA 94304 USA
来源
关键词
Aneurysm; Cerebral; Brain; Artificial intelligence; AI;
D O I
10.1016/j.jstrokecerebrovasdis.2022.106690
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: Cerebral aneurysms may result in significant mor-bidity and mortality. Identification of these aneurysms on CT Angiography (CTA) studies is critical to guide patient treat-ment. Artificial intelligence platforms to assist with auto-mated aneurysm detection are of high interest. We determined the performance of a semi-automated artificial intelligence software program (RAPID Aneurysm) for the detection of cerebral aneurysms. Materials and Methods: RAPID Aneurysm was used to detect retrospec-tively the presence of cerebral aneurysms in CTA studies per-formed between January 2019 and December 2020. The gold standard was aneurysm presence and location as determined by the consensus of three expert neuroradiologists. Aneu-rysm detection accuracy, sensitivity, specificity, positive pre-dictive value, negative predictive value, and positive and negative likelihood ratios by RAPID Aneurysm were deter-mined. Results: 51 patients (mean age, 56</n>15; 24 women [47.1%]) with a single CTA were included. A total of 60 aneurysms were identified. RAPID Aneurysm had a sensitiv-ity of 0.950 (95% CI: 0.863-0.983), specificity of 1.000 (95% CI: 0.996-1.000), a positive predictive value (PPV) of 1.000 (95% CI: 0.937-1.000), a negative predictive value (NPV) of 0.997 (95% CI: 0.991-0.999), and an accuracy of 0.997 (95% CI: 0.991-0.999) for cerebral aneurysm detection. Conclusions: RAPID Aneurysm is highly accurate for the detection of cerebral aneurysms on CTA.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Pitfall of CT angiography for an aneurysm around middle cerebral artery bifurcation
    Seo, Bo-Ra
    Joo, Sung Pil
    Kim, Tae-Sun
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2009, 23 (02) : 209 - 210
  • [22] Acute Cerebral Aneurysm Re-Bleeding During CT Angiography
    Ishige, N.
    Tanno, H.
    Ozaki, H.
    Fuse, Y.
    [J]. CEREBROVASCULAR DISEASES, 2013, 36 : 64 - 64
  • [23] Detection of a fusiform coronary artery aneurysm using CT angiography
    Chen J.K.
    Johnson P.T.
    Fishman E.K.
    [J]. Emergency Radiology, 2006, 13 (2) : 99 - 101
  • [24] Subarachnoid hemorrhage: Aneurysm detection and preoperative evaluation with CT angiography
    Velthuis, BK
    Rinkel, GJE
    Ramos, LMP
    Witkamp, TD
    van der Sprenkel, JWB
    Vandertop, WP
    van Leeuwen, MS
    [J]. RADIOLOGY, 1998, 208 (02) : 423 - 430
  • [25] Sinus valsalva aneurysm on cardiac CT angiography: Assessment and detection
    Troupis, John M.
    Nasis, Arthur
    Pasricha, Sundeep
    Patel, Mihir
    Ellims, Andris Harald
    Seneviratne, Sujith
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 444 - 447
  • [26] RUPTURE OF CEREBRAL ANEURYSM DURING ANGIOGRAPHY
    LIU, CT
    [J]. CALIFORNIA MEDICINE, 1965, 103 (01): : 54 - &
  • [27] Contrast settling in cerebral aneurysm angiography
    Wang, ZJ
    Hoffmann, KR
    Wang, Z
    Rudin, S
    Guterman, LR
    Meng, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3171 - 3181
  • [28] VANISHING CEREBRAL ANEURYSM IN SERIAL ANGIOGRAPHY
    MORITAKE, K
    HANDA, H
    OHTSUKA, S
    HASHIMOTO, N
    [J]. SURGICAL NEUROLOGY, 1981, 16 (01): : 36 - 40
  • [29] RUPTURE OF CEREBRAL ANEURYSM DURING ANGIOGRAPHY
    KARTTUNEN, A
    PYHTINEN, J
    TANSKA, EL
    RONTY, H
    [J]. NEUROCHIRURGIA, 1986, 29 (01) : 31 - 33
  • [30] Evaluation of contour of unruptured cerebral aneurysm using three-dimensional CT cisternogram
    Onoda, K
    Satoh, T
    Tsuchimoto, S
    Katsumata, A
    [J]. ACTA MEDICA OKAYAMA, 2004, 58 (03) : 157 - 162