A novel crystal-analyzer phase retrieval algorithm and its noise property

被引:7
|
作者
Bao, Yuan [1 ,2 ]
Wang, Yan [2 ]
Li, Panyun [2 ]
Wu, Zhao [1 ]
Shao, Qigang [1 ]
Gao, Kun [1 ]
Wang, Zhili [1 ]
Ju, Zaiqiang [2 ]
Zhang, Kai [2 ]
Yuan, Qingxi [2 ]
Huang, Wanxia [2 ]
Zhu, Peiping [1 ,2 ,3 ]
Wu, Ziyu [1 ,2 ]
机构
[1] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Beijing Ctr Math & Informat Interdisciplinary Sci, Beijing 100048, Peoples R China
基金
中国国家自然科学基金;
关键词
diffraction enhanced imaging; phase retrieval; noise in imaging systems; X-RAY PHASE; IMAGING PERFORMANCE; CONTRAST; ABSORPTION; REFRACTION; SCATTERING; SPECTRUM;
D O I
10.1107/S1600577515003616
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A description of the rocking curve in diffraction enhanced imaging (DEI) is presented in terms of the angular signal response function and a simple multi-information retrieval algorithm based on the cosine function fitting. A comprehensive analysis of noise properties of DEI is also given considering the noise transfer characteristic of the X-ray source. The validation has been performed with synchrotron radiation experimental data and Monte Carlo simulations based on the Geant4 toolkit combined with the refractive process of X-rays, which show good agreement with each other. Moreover, results indicate that the signal-to-noise ratios of the refraction and scattering images are about one order of magnitude better than that of the absorption image at the edges of low-Z samples. The noise penalty is drastically reduced with the increasing photon flux and visibility. Finally, this work demonstrates that the analytical method can build an interesting connection between DEI and GDPCI (grating-based differential phase contrast imaging) and is widely suitable for a variety of measurement noise in the angular signal response imaging prototype. The analysis significantly contributes to the understanding of noise characteristics of DEI images and may allow improvements to the signal-to-noise ratio in biomedical and material science imaging.
引用
收藏
页码:786 / 795
页数:10
相关论文
共 50 条
  • [31] PGPAL: A Monotonic Iterative Algorithm for Phase-Retrieval Under the Presence of Poisson-Gaussian Noise
    Fatima, Ghania
    Babu, Prabhu
    IEEE SIGNAL PROCESSING LETTERS, 2022, 29 : 533 - 537
  • [32] Novel Rotation Algorithm for Phase unwrapping to Solve Problems of Holes and Noise (AFPA)
    Weng, Jing-Feng
    Lo, Yu-Lung
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN2013), 2013, 8769
  • [33] A stable direct algorithm for image retrieval from its noisy Fourier transform phase
    Lyuboshenko, IV
    Akhmetshin, AM
    1996 IEEE DIGITAL SIGNAL PROCESSING WORKSHOP, PROCEEDINGS, 1996, : 255 - 258
  • [34] Noise robust Zernike phase retrieval via learning based algorithm only with 2-step phase shift measurements
    Kim, Hansol
    Jeong, Youngmo
    Lee, Kyoungjae
    Jeong, Yoonchan
    OPTICS EXPRESS, 2023, 31 (19) : 30248 - 30266
  • [35] A novel noise reduction algorithm and its application in failure information extraction of bearing
    Zhang, Yi
    Yu, Mingyue
    Wang, Xin
    Han, Chuang
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2024,
  • [36] A Novel CNN-Based Channel Estimation Algorithm in the Presence of Phase Noise and CFO
    Coutinho, Fabio D. L.
    Silva, Hugerles S.
    Georgieva, Petia
    Oliveira, Arnaldo S. R.
    IEEE WIRELESS COMMUNICATIONS LETTERS, 2024, 13 (01) : 193 - 197
  • [37] The Property of Signal-to-noise and Its Variation over Spatial Frequency in Differential Phase Contrast CT
    Tang, Xiangyang
    Yang, Yi
    Tang, Shaojie
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3613 - 3616
  • [38] Common-mode property of amplitude-to-phase noise conversion in carrier-envelope phase measurement and its effect on phase stabilization
    Kakehata, Masayuki
    Oota, Wataru
    Takada, Hideyuki
    Nakamura, Shinki
    Torizuka, Kenji
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [39] A novel two-stage phase noise estimation algorithm for coherent optical OFDM systems
    Yuan, Jianguo
    Bi, Wenjuan
    Bi, Wenjie
    Xu, Liang
    OPTIK, 2013, 124 (24): : 7053 - 7055
  • [40] Calibration Method of Liquid-Crystal Spatial Light Modulator Based on a 1-D Phase Retrieval Algorithm
    Zhou, Yifu
    Wei, Hanyue
    Ren, Liyong
    Liang, Jian
    IEEE PHOTONICS JOURNAL, 2023, 15 (02):