The role of postoperative Tc-99m pertechnetate scintigraphy in estimation of remnant mass and prediction of successful ablation in patients with differentiated thyroid cancer

被引:18
|
作者
Ozdemir, Didem [1 ]
Cuhaci, Fatma N. [1 ]
Ozdemir, Elif [2 ]
Aydin, Cevdet [1 ]
Ersoy, Reyhan [1 ]
Turkolmez, Seyda [2 ]
Cakir, Bekir [1 ]
机构
[1] Ankara Yildirim Beyazit Univ, Dept Endocrinol & Metab, Sch Med, TR-06800 Ankara, Turkey
[2] Ankara Yildirim Beyazit Univ, Sch Med, Dept Nucl Med, Ankara, Turkey
关键词
ablation; differentiated thyroid cancer; postoperative remnant; Tc-99m pertechnetate scintigraphy; VASCULAR RETENTION; CARCINOMA; PAPILLARY;
D O I
10.1097/MNM.0000000000000492
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Surgery and radioactive iodine (RAI) ablation constitute the mainstay of the treatment of differentiated thyroid carcinoma (DTC). In this study, we aimed to evaluate the diagnostic value of postoperative early Tc-99m pertechnetate scanning to detect remnant thyroid tissue and predict ablation success. Methods DTC patients evaluated with postoperative Tc-99m pertechnetate scintigraphy and treated with RAI between January 2007 and December 2014 were recruited. The results of Tc-99m pertechnetate scanning were compared with therapeutic I-131 whole-body scanning (TxWBS) and diagnostic I-131 whole-body scanning (DxWBS) performed 6-9 months after RAI. Results There were 154 (21.5%) male and 563 (78.5%) female patients, with a mean age of 49.11 +/- 12.35 years. Postoperative Tc-99m pertechnetate scanning was positive in 499 patients (69.6%) and negative in 218 (30.4%) patients. There were 673 (93.9%) patients with a positive TxWBS scan and 44 (6.1%) patients with negative TxWBS scan. Considering TxWBS as the standard test, sensitivity, specificity, positive predictive value, and negative predictive value of Tc-99m pertechnetate scanning were 72.2, 70.5, 97.4, and 14.2%, respectively. DxWBS was positive in 57 (9.0%) and negative in 564 (91%) patients. Ablation dose was higher and preablation thyroglobulin was lower in patients with negative DxWBS (P = 0.001 and 0.04, respectively). Overall, 171 (92.9%) of 184 patients with negative Tc-99m pertechnetate had negative DxWBS. Conclusion Postoperative Tc-99m pertechnetate scintigraphy has a high positive predictive value to detect remnant tissue in patients with DTC. Although negative Tc-99m pertechnetate scanning does not indicate removal of all thyroid tissue, it is related to successful ablation in more than 90% of patients. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:640 / 645
页数:6
相关论文
共 50 条
  • [31] Tc-99m sestamibi parathyroid gland scintigraphy: added value of Tc-99m pertechnetate thyroid imaging for increasing interpretation confidence and avoiding additional testing
    Powell, Daniel K.
    Nwoke, Franklin
    Goldfarb, Richard C.
    Ongseng, Fukiat
    CLINICAL IMAGING, 2013, 37 (03) : 475 - 479
  • [32] Tc-99m HYNIC-TOC scintigraphy in dedifferentiated thyroid cancer
    Agrawal, Kanhaiyalal
    Patro, P. Sai Sradha
    Preetam, C.
    BMJ CASE REPORTS, 2019, 12 (04)
  • [33] CLINICAL EVALUATION OF TC-99M BLEOMYCIN SCINTIGRAPHY FOR DIAGNOSIS OF THYROID CANCER
    MORI, T
    HAMAMOTO, K
    MORITA, R
    TORIZUKA, K
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (06) : 518 - 519
  • [34] Tc-99m Sestamibi parathyroid scintigraphy in patients with multinodular thyroid glands
    Tomas, MB
    Kalapparambath, T
    Tronco, GG
    Afriyie, MO
    Palestro, CJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1214 - 1214
  • [35] The value of Tc-99m tetrofosmin thyroid scintigraphy in patients with nodular goiter
    Karayalçin Ü.
    Çiftçi F.
    Boz A.
    Boz S.
    Karayalçin B.
    Annals of Nuclear Medicine, 1997, 11 (4) : 285 - 290
  • [36] Accidental discovery of lung metastases from Differentiated Thyroid Cancer by Tc-99m pertechnetate scan in a patient with secondary hyperparathyroidism
    Campenni, A.
    Ruggeri, R. M.
    Santoro, D.
    Bellinghieri, G.
    Vigneri, C.
    Cucinotta, M.
    Sindoni, A.
    Baldari, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S395 - S395
  • [37] Metastatic insular thyroid carcinoma: Visualized on Tc-99m pertechnetate, Tc-99m MDP and iodine-131 scintigraphy; a review of the literature for other radionuclide agents
    Pinar Özgen Kiratli
    P. Pelin Özcan Kara
    Eser Lay Ergün
    Gökhan GedIkoğlu
    Annals of Nuclear Medicine, 2004, 18 : 443 - 446
  • [38] Metastatic insular thyroid carcinoma:: Visualized on Tc-99m pertechnetate, Tc-99m MDP and iodine-131 scintigraphy;: a review of the literature for other radionuclide agents
    Kiratli, PO
    Kara, PPO
    Ergün, EL
    Gedikoglu, G
    ANNALS OF NUCLEAR MEDICINE, 2004, 18 (05) : 443 - 446
  • [39] The Prognostic Role of Tc-99m Pertechnetate Thyroid Scintigraphy Before Fixed Dose Radioiodine Therapy of Toxic Multinodular Goiter for Outcome
    Yuksel, D.
    Kirac, S.
    Yaylali, O.
    Uguz, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S447 - S447
  • [40] Prognostic role of Tc-99m pertechnetate thyroid scintigraphy prior to fixed-dose radioiodine therapy of toxic multinodular goiters
    Yuksel, Dogangun
    Kirac, Fatma Suna
    Yaylali, Olga
    Uguz, Isil Demiray
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2011, 41 (06) : 981 - 988