Characterization and quantification of cerebral edema induced by synchrotron x-ray microbeam radiation therapy

被引:78
|
作者
Serduc, Raphael [1 ,2 ]
de Looij, Yohan Van [1 ,2 ]
Francony, Gilles [1 ,2 ]
Verdonck, Olivier [1 ,2 ]
Van der Sanden, Boudewijn [1 ,2 ]
Laissue, Jean [3 ]
Farion, Regine [1 ,2 ]
Braeuer-Krisch, Elke [4 ]
Siegbahn, Erik Albert [4 ]
Bravin, Alberto [4 ]
Prezado, Yolanda [4 ]
Segebarth, Christoph [1 ,2 ]
Remy, Chantal [1 ,2 ]
Lahrech, Hana [1 ,2 ]
机构
[1] INSERM, U836, F-38043 Grenoble, France
[2] Univ Grenoble 1, Inst Neurosci, F-38043 Grenoble, France
[3] Univ Bern, Inst Pathol, CH-3012 Bern, Switzerland
[4] European Synchrotron Radiat Facil, F-38043 Grenoble, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 05期
关键词
D O I
10.1088/0031-9155/53/5/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cerebral edema is one of the main acute complications arising after irradiation of brain tumors. Microbeam radiation therapy (MRT), an innovative experimental radiotherapy technique using spatially fractionated synchrotron x-rays, has been shown to spare radiosensitive tissues such as mammal brains. The aim of this studywas to determine if cerebral edema occurs after MRT using diffusion-weighted MRI and microgravimetry. Prone Swiss nude mice's heads were positioned horizontally in the synchrotron x-ray beam and the upper part of the left hemispherewas irradiated in the antero-posterior direction by an array of 18 planar microbeams (25 mm wide, on-center spacing 211 mm, height 4 mm, entrance dose 312 Gy or 1000 Gy). An apparent diffusion coefficient (ADC) was measured at 7 T 1, 7, 14, 21 and 28 days after irradiation. Eventually, the cerebral water content (CWC) was determined by microgravimetry. The ADC and CWC in the irradiated ( 312 Gy or 1000 Gy) and in the contralateral non-irradiated hemispheres were not significantly different at all measurement times, with two exceptions: (1) a 9% ADC decrease (p < 0.05) was observed in the irradiated cortex 1 day after exposure to 312 Gy, (2) a 0.7% increase ( p < 0.05) in the CWC was measured in the irradiated hemispheres 1 day after exposure to 1000 Gy. The results demonstrate the presence of a minor and transient cellular edema (ADC decrease) at 1 day after a 312 Gy exposure, without a significant CWC increase. One day after a 1000 Gy exposure, the CWC increased, while the ADC remained unchanged and may reflect the simultaneous presence of cellular and vasogenic edema. Both types of edema disappear within a week after microbeam exposure which may confirm the normal tissue sparing effect of MRT.
引用
收藏
页码:1153 / 1166
页数:14
相关论文
共 50 条
  • [1] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [2] Synchrotron microbeam x-ray radiation damage in semiconductor layers
    Polvino, Sean M.
    Murray, Conal E.
    Kalenci, Oezgur
    Noyan, I. C.
    Lai, Barry
    Cai, Zhoghou
    [J]. APPLIED PHYSICS LETTERS, 2008, 92 (22)
  • [3] A theoretical study to focus a polychromatic synchrotron X-ray beam for microbeam radiation therapy
    Iskandar, Kyrollos
    Crosbie, Jeffrey C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 997
  • [4] Microbeam radiation therapy at a laser-based compact synchrotron x-ray source
    Burger, Karin
    Ilicic, Katarina
    Hunger, Annique
    Dierolf, Martin
    Guenther, Benedikt
    Schmid, Ernst
    Walsh, Dietrich W. M.
    Urban, Theresa
    Bartzsch, Stefan
    Radtke, Amira
    Eggl, Elena
    Achterhold, Klaus
    Gleich, Bernhard
    Combs, Stephanie E.
    Molls, Michael
    Schmid, Thomas E.
    Pfeiffer, Franz
    Wilkens, Jan J.
    [J]. 2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [5] X-ray spectrometric applications of a synchrotron x-ray microbeam
    Iida, A
    [J]. X-RAY SPECTROMETRY, 1997, 26 (06) : 359 - 363
  • [6] Hydrogenated amorphous silicon high flux x-ray detectors for synchrotron microbeam radiation therapy
    Large, Matthew J.
    Bizzarri, Marco
    Calcagnile, Lucio
    Caprai, Mirco
    Caricato, Anna Paola
    Catalano, Roberto
    Cirrone, Giuseppe A. P.
    Croci, Tommaso
    Cuttone, Giacomo
    Dunand, Sylvain
    Fabi, Michele
    Frontini, Luca
    Gianfelici, Benedetta
    Grimani, Catia
    Ionica, Maria
    Kanxheri, Keida
    Lerch, Michael L. F.
    Liberali, Valentino
    Martino, Maurizio
    Maruccio, Giuseppe
    Mazza, Giovanni
    Menichelli, Mauro
    Monteduro, Anna Grazia
    Moscatelli, Francesco
    Morozzi, Arianna
    Pallotta, Stefania
    Papi, Andrea
    Passeri, Daniele
    Pedio, Maddalena
    Petringa, Giada
    Peverini, Francesca
    Piccolo, Lorenzo
    Placidi, Pisana
    Quarta, Gianluca
    Rizzato, Silvia
    Rossi, Alessandro
    Rossi, Giulia
    de Rover, Vincent
    Sabbatini, Federico
    Servoli, Leonello
    Stabile, Alberto
    Talamonti, Cinzia
    Tosti, Luca
    Villani, Mattia
    Wheadon, Richard J.
    Wyrsch, Nicolas
    Zema, Nicola
    Petasecca, Marco
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13):
  • [7] Hard X-ray microbeam production with synchrotron radiation: Application to microanalysis
    Chevallier, P
    Populus, P
    Firsov, A
    [J]. EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, : 179 - 184
  • [8] Synchrotron X-Ray Boost in the Microbeam Radiation Therapy Mode Improves Glioma Control After Conventional X-Ray Fractions
    Bouchet, A.
    Potez, M. T.
    Flaender, M.
    Schaad, L.
    Rome, C.
    Farion, R.
    Laissue, J. A.
    Grotzer, M.
    Djonov, V.
    Elleaume, H.
    Brun, E.
    Serduc, R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E94 - E95
  • [9] Application of Conventional and Microbeam Synchrotron Radiation X-Ray Fluorescence and Absorption for the Characterization of Human Nails
    Katsikini, M.
    Mavromati, A.
    Pinakidou, F.
    Paloura, E. C.
    Gioulekas, D.
    Ioannides, D.
    Erko, A.
    Zizak, I.
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2010, 10 (09) : 6266 - 6275
  • [10] Hard x-ray microbeam production with synchrotron radiation: Application to microanalysis
    Chevallier, P
    Populus, P
    Firsov, A
    [J]. X-RAY SPECTROMETRY, 1999, 28 (05) : 348 - 351