Applicability of Methanol as a New Marker for Paper Degradation in Power Transformers

被引:68
|
作者
Schaut, Annelore [1 ]
Autru, Stijn [1 ]
Eeckhoudt, Steve [1 ]
机构
[1] Laborelec, B-1630 Linkebeek, Belgium
关键词
GSU transformers; oil analyses; methanol; furanic compounds; end-of-life; early paper aging; CELLULOSE;
D O I
10.1109/TDEI.2011.5739459
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study was designed to examine methanol as a new aging marker of insulating paper. An analytical GC-MS method coupled to headspace injection was developed, followed by a validation. To further validate the possible applicability of methanol for different transformer conditions some laboratory studies were performed such as a stability and an aging test. Oil samples of power transformers of several Belgian nuclear and coal-fired power plants have been analyzed since mid 2009 and are followed-up periodically to correlate the results with the analysis of the furanic compounds which have been used since mid 1980s as oil soluble degradation products of the insulating winding paper. It seemed that while no 2FAL was present some considerable amount of MeOH was detected which revealed some paper degradation. A second real case study was started to further correlate MeOH and 2FAL results. From these laboratory and real case studies it seemed that MeOH is a very promising marker for paper degradation in power transformers.
引用
收藏
页码:533 / 540
页数:8
相关论文
共 50 条
  • [1] Evaluation of the Chemical Stability of Methanol Generated during Paper Degradation in Power Transformers
    von Steinkirch Souza, Estrela Mariana Prux
    Mildemberger, Larissa
    Akcelrud, Leni
    Andreoli, Mario Carlos
    dos Santos, Kassia
    da Silva, Guilherme Cunha
    da Motta, Heloisa Nunes
    Gulmine, Joseane Valente
    Munaro, MariIda
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (05) : 3209 - 3214
  • [2] Methanol marker for the thermal performance qualification of power transformers
    Ryadi, Mohamed
    Tanguy, Alain
    Jalbert, Jocelyn
    [J]. 2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 387 - 391
  • [3] Thermal Degradation of Cellulose Paper Insulation in Power Transformers
    Mirzaie, M.
    Gholami, A.
    Tayyebi, H.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 673 - +
  • [4] Radiation-chemical degradation of the paper insulation of power transformers
    V. N. Bondareva
    V. B. Komarov
    A. F. Seliverstov
    B. G. Ershov
    M. Yu. L’vov
    S. V. Trifonova
    [J]. High Energy Chemistry, 2005, 39 : 196 - 197
  • [5] Radiation-chemical degradation of the paper insulation of power transformers
    Bondareva, VN
    Komarov, VB
    Seliverstov, AF
    Ershov, BG
    L'vov, MY
    Trifonova, SV
    [J]. HIGH ENERGY CHEMISTRY, 2005, 39 (03) : 196 - 197
  • [6] Aging Degradation of Insulation Paper in Power Transformers by XRD Method
    Peng, Lei
    Fu, Qiang
    Lin, Musong
    Qian, Yihua
    Lv, Wangyan
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [7] Methanol as an Ageing Marker for In Service Transformers
    Bare, Charles E., II
    Merritt, Stanley Y.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) : 6598 - 6602
  • [8] Methanol as an Ageing Marker for In Service Transformers
    Bare, Charles E., II
    Merritt, Stanley Y.
    [J]. IEEE CONFERENCE RECORD OF 2017 ANNUAL PULP, PAPER AND FOREST INDUSTRIES TECHNICAL CONFERENCE (PPFIC), 2017,
  • [9] Methanol Marker for the Detection of Insulating Paper Degradation in Transformer Insulating Oil
    Jalbert, Jocelyn
    Rodriguez-Celis, Esperanza M.
    Arroyo-Fernandez, Oscar H.
    Duchesne, Steve
    Morin, Brigitte
    [J]. ENERGIES, 2019, 12 (20)
  • [10] Understanding ethanol versus methanol formation from insulating paper in power transformers
    Rodriguez-Celis, E. M.
    Duchesne, S.
    Jalbert, J.
    Ryadi, M.
    [J]. CELLULOSE, 2015, 22 (05) : 3225 - 3236