Design guidelines for push-pull ventilation systems through computational fluid dynamics modeling

被引:30
|
作者
Rota, R [1 ]
Nano, G [1 ]
Canossa, L [1 ]
机构
[1] Politecn Milan, Dip Chim Fis Applicata, I-20131 Milan, Italy
来源
AIHAJ | 2001年 / 62卷 / 02期
关键词
air draft; computational fluid dynamics (CFD) modeling; design; push-pull ventilation; tank width;
D O I
10.1080/15298660108984616
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Open surface tanks often are used in industrial practice. When harmful substances are involved, control of worker exposure requires the use of a focal ventilation system. The push-pull system, among others, involves a jet of air that is blown from one side of the tank and collected by an exhaust hood on the opposite side; this system can save up to 50% of the ventilation air. Several guidelines are available for design of such a ventilation system, mainly based on experimental results. However, their validity is confined inside a narrow operating window, in this work a mathematical model developed based on computational fluid dynamics has been used to extend the validity of the existing guidelines outside the range in which they have been validated, with particular reference to tank width and to the velocity of the air drafts.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [41] Required performance of pushed air in push-pull ventilation system
    Komine, H
    Tsuji, K
    Mori, Y
    [J]. ADVANCES IN THE PREVENTION OF OCCUPATIONAL RESPIRATORY DISEASES, 1998, 1153 : 1120 - 1126
  • [42] Push-pull ventilation system: A CFD approach for the performance analysis
    DETEC, University of Naples, Federico II, Piazzale Tecchio 80, 80125 Naples, Italy
    不详
    [J]. International Journal of Ambient Energy, 2007, 28 (03): : 123 - 134
  • [43] Helical push-pull systems for solar cells: Electrochemical, computational, photovoltaic and NMR data
    Dova, Davide
    Cauteruccio, Silvia
    Manfredi, Norberto
    Prager, Stefan
    Dreuw, Andreas
    Arnaboldi, Serena
    Mussini, Patrizia R.
    Licandro, Emanuela
    Abbotto, Alessandro
    [J]. DATA IN BRIEF, 2018, 21 : 2339 - 2349
  • [44] Selecting technological paradigms beyond push-pull dynamics
    Barbera-Tomas, David
    De los Reyes-Lopez, Ernesto
    [J]. 2007 ATLANTA CONFERENCE ON SCIENCE, TECHNOLOGY AND INNOVATION POLICY, 2007, : 61 - 61
  • [45] Experimental modeling and application of push-pull electrostatic speakers
    Chiang, Hsin-Yuan
    Huang, Yu-Hsi
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 146 (04): : 2619 - 2631
  • [46] Push-pull direct modeling of solid CAD models
    Zou, Qiang
    Feng, Hsi-Yung
    [J]. ADVANCES IN ENGINEERING SOFTWARE, 2019, 127 : 59 - 69
  • [47] EVALUATION OF CAPTURE EFFICIENCIES OF LARGE PUSH-PULL VENTILATION SYSTEMS WITH BOTH VISUAL AND TRACER TECHNIQUES
    WOODS, JN
    MCKARNS, JS
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1995, 56 (12): : 1208 - 1214
  • [48] Study on the Characteristics of Flow Field Affected by Obstacle with Push-Pull Ventilation
    Zhou, Yu
    Wang, Yi
    Zheng, Kai
    Meng, Xiaojing
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 167 - 174
  • [49] Numerical modelling of the flow patterns induced by a push-pull ventilation system
    Robinson, M
    Ingham, DB
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1996, 40 (03): : 293 - 310
  • [50] IMPROVED LOCAL EXHAUST CONTROL BY DIRECTED PUSH-PULL VENTILATION SYSTEM
    HAMPL, V
    HUGHES, RT
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (01): : 59 - 65