Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

被引:16
|
作者
Chang, Chih-Ju [1 ,2 ,3 ]
Lin, Geng-Li [3 ]
Tse, Alex [3 ]
Chu, Hong-Yu [3 ]
Tseng, Ching-Shiow [3 ]
机构
[1] Cathay Gen Hosp, Dept Neurosurg, Taipei 10630, Taiwan
[2] Fu Jen Catholic Univ, Sch Med, Dept Med, New Taipei City 24205, Taiwan
[3] Natl Cent Univ, Dept Mech Engn, Taoyuan 32001, Taoyuan County, Taiwan
关键词
2-D/3-D RIGID REGISTRATION; FLUOROSCOPIC X-RAY; SIMILARITY MEASURES;
D O I
10.1155/2015/478062
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell's method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlationmeasure method with Downhill simplex algorithm obtainsmaximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR) images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3792 - 3793
  • [32] C-arm CT-guided 3D navigation of percutaneous interventions [C-Bogen-CT-unterstützte 3D-Navigation perkutaner Interventionen]
    Becker H.-C.
    Meissner O.
    Waggershauser T.
    [J]. Der Radiologe, 2009, 49 (9): : 852 - 855
  • [33] Simultaneous 3D-2D image registration and C-arm calibration: Application to endovascular image-guided interventions
    Mitrovic, Uros
    Pernus, Franjo
    Likar, Bostjan
    Spiclin, Ziga
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6433 - 6447
  • [34] D/2D Image Registration Method for Joint Motion Analysis Using Low-Quality Images from Mini C-Arm Machines
    Ghafurian, Soheil
    Hacihaliloglu, Ilker
    Metaxas, Dimitris N.
    Tan, Virak
    Li, Kang
    [J]. MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [35] Intraoperative C-arm fluoroscopy-based 3D navigation for intraventricular endoscopic intervention
    Herbowski, L.
    Sagan, L.
    Szylak, R.
    Salapa, P.
    Harat, A.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (04) : 537 - 539
  • [36] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    [J]. UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [37] Mobile C-arm 3D Reconstruction in the Presence of Uncertain Geometry
    Rottman, Caleb
    McBride, Lance
    Cheryauka, Arvidas
    Whitaker, Ross
    Joshi, Sarang
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 692 - 699
  • [38] Sterility of C-arm fluoroscopy during spinal surgery
    Biswas, Debdut
    Bible, Jesse E.
    Whang, Peter G.
    Simpson, Andrew K.
    Grauer, Jonathan N.
    [J]. SPINE, 2008, 33 (17) : 1913 - 1917
  • [39] 2-D/3-D REGISTRATION OF C-ARM CT VOLUMES WITH FLUOROSCOPIC IMAGES BY SPINES FOR PATIENT MOVEMENT CORRECTION DURING ELECTROPHYSIOLOGY
    Liao, Rui
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1213 - 1216
  • [40] Comparative irradiation between peroperative 2D C-arm and 3D CBCT in children: a study on phantoms
    Prod'homme, Marc
    Sans-Merce, Marta
    Pitteloud, Nicolas
    Damet, Jerome
    Lascombes, Pierre
    [J]. SWISS MEDICAL WEEKLY, 2018, 148 : 59S - 59S