Equivalent Dose Rate Field Structure Investigation Using Optimum Interpolation Method

被引:0
|
作者
Gustas, L. J. [1 ]
Kleiza, J. [1 ]
Styra, D. [1 ]
机构
[1] Vilnius Gediminas Tech Univ, LT-10223 Vilnius, Lithuania
关键词
radon decay products; optimum interpolation method; equivalent dose rate;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents an investigation of equivalent dose rate (EDR) field structure at the Baltic seacoast. EDR measurements were carried out near Juodkrante July 7, 9 and 12 of 2008. Average extreme values were 41 and 98 nSv/h, and in individual cases 40 and 130 nSv/h. EDR was measured in 63 points and its field structure was obtained by optimum interpolation method. Measurement number was decreased up to 33 and 18 to get EDR field structure. The coincidence between measured and calculated values was satisfactory.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [41] Investigation of irregular radiation field-based proton therapy using conformal dose layer stacking method
    Shao, W.
    Tang, X.
    Geng, C.
    Shu, D.
    Gong, C.
    Zhang, X.
    Guan, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (02): : 295 - 306
  • [42] Investigation on the damage process and the deformation of concrete using meso element equivalent method
    Jin, Liu
    Du, Xiuli
    Ma, Guowei
    [J]. ADVANCES IN ENGINEERING PLASTICITY XI, 2013, 535-536 : 578 - +
  • [43] Investigation of a structure field at electrodynamics system with method of magnet probe
    Bulba, O. P.
    Osipov, A. M.
    Vuntesmeri, Vol. S.
    [J]. VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2007, (34): : 118 - 123
  • [44] Investigation of drag effect using the field signature method
    Wan, Zhengjun
    Liao, Junbi
    Tian, Gui Yun
    Cheng, Liang
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (08)
  • [45] USING METHOD OF EQUIVALENT LINEAR ANTENNA IN STATISTICAL ANALYSIS OF FIELD OF A PLANAR APERTURE
    YAMAYKIN, VE
    [J]. RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1966, 11 (05): : 798 - &
  • [46] Reconstruction of the sound field above a reflecting plane using the equivalent source method
    Bi, Chuan-Xing
    Jing, Wen-Qian
    Zhang, Yong-Bin
    Lin, Wang-Lin
    [J]. JOURNAL OF SOUND AND VIBRATION, 2017, 386 : 149 - 162
  • [47] Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am-Be neutron source
    Li, Gang
    Xu, Jiayun
    Zhang, Jie
    [J]. APPLIED RADIATION AND ISOTOPES, 2015, 95 : 122 - 128
  • [48] Determining Blocked Equivalent Square Field Size Using an MLC Centroid Method
    Taylor, W.
    Woods, K.
    DiCostanzo, D.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E301 - E301
  • [49] Sound field reconstruction using compressed modal equivalent point source method
    [J]. Bi, Chuan-Xing (cxbi@hfut.edu.cn), 1600, Acoustical Society of America (141):
  • [50] A method of high bit-rate data hiding in music using spline interpolation
    Fujimoto, Ryuta
    Iwaki, Mamoru
    Kiryu, Tohru
    [J]. IIH-MSP: 2006 INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATION HIDING AND MULTIMEDIA SIGNAL PROCESSING, PROCEEDINGS, 2006, : 11 - +