Equivalent Dose Rate Field Structure Investigation Using Optimum Interpolation Method

被引:0
|
作者
Gustas, L. J. [1 ]
Kleiza, J. [1 ]
Styra, D. [1 ]
机构
[1] Vilnius Gediminas Tech Univ, LT-10223 Vilnius, Lithuania
关键词
radon decay products; optimum interpolation method; equivalent dose rate;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents an investigation of equivalent dose rate (EDR) field structure at the Baltic seacoast. EDR measurements were carried out near Juodkrante July 7, 9 and 12 of 2008. Average extreme values were 41 and 98 nSv/h, and in individual cases 40 and 130 nSv/h. EDR was measured in 63 points and its field structure was obtained by optimum interpolation method. Measurement number was decreased up to 33 and 18 to get EDR field structure. The coincidence between measured and calculated values was satisfactory.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [1] A PRACTICAL METHOD FOR EVALUATING NEUTRON DOSE EQUIVALENT RATE
    YOSHIDA, Y
    TATSUTA, H
    RYUFUKU, H
    KITANO, K
    FUKUDA, S
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1966, 3 (11): : 473 - &
  • [2] A PRACTICAL METHOD FOR EVALUATING NEUTRON DOSE EQUIVALENT RATE
    YOSHIDA, Y
    TATSUTA, H
    RYUFUKU, H
    KITANO, K
    FUKUDA, S
    [J]. HEALTH PHYSICS, 1966, 12 (12): : 1753 - +
  • [3] Assessment of ambient dose equivalent rate distribution patterns in a forested-rugged terrain using field-measured and modeled dose equivalent rates
    Yasumiishi, Misa
    Masoudi, Pedram
    Nishimura, Taku
    Ochi, Kotaro
    Ye, Xiang
    Aldstadt, Jared
    Komissarov, Mikhail
    [J]. RADIATION MEASUREMENTS, 2023, 168
  • [4] Investigation of real tissue water equivalent path lengths using an efficient dose extinction method
    Zhang, Rongxiao
    Baer, Esther
    Jee, Kyung-Wook
    Sharp, Gregory C.
    Flanz, Jay
    Lu, Hsiao-Ming
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14): : 5640 - 5651
  • [5] APPLICATION OF CORRECTION METHOD TO NUMERICAL-ANALYSIS USING AN OPTIMUM INTERPOLATION
    KLUGE, J
    [J]. ZEITSCHRIFT FUR METEOROLOGIE, 1976, 26 (01): : 20 - 24
  • [6] INVESTIGATION OF AN EXPERIMENTAL-METHOD FOR THE DETERMINATION OF DOSE EQUIVALENT IN THE ICRU SPHERE
    HARTMANN, GH
    COYNE, JJ
    MORHART, A
    SCHUHMACHER, H
    MENZEL, HG
    [J]. RADIATION PROTECTION DOSIMETRY, 1984, 9 (03) : 207 - 210
  • [7] Digital Dose Rate Equivalent Meter for Neutron-Gamma Mixed Field
    Culen, Jiri
    Kral, Jan
    Jancar, Ales
    Kopecky, Zdenek
    Mravec, Filip
    Matej, Zdenek
    [J]. 2022 IEEE SENSORS, 2022,
  • [8] Calculation of the Equivalent Dose Rate Distribution Using Data Obtained with a γ Locator
    V. N. Potapov
    A. V. Chesnokov
    S. B. Shcherbak
    [J]. Atomic Energy, 2002, 92 : 357 - 366
  • [9] Calculation of the equivalent dose rate distribution using data obtained with a γ locator
    Potapov, VN
    Chesnokov, AV
    Shcherbak, SB
    [J]. ATOMIC ENERGY, 2002, 92 (04) : 357 - 366
  • [10] Investigation of Dose Interpolation Errors with a 4D Monte Carlo Method
    Zhong, H.
    Siebers, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)