Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method

被引:96
|
作者
Wang, He [1 ]
Adam, S. Garden [2 ]
Zhang, Lifei [1 ]
Wei, Xiong [2 ]
Ahamad, Anesa [2 ]
Kuban, Deborah A. [2 ]
Komaki, Ritsuko [2 ]
O'Daniel, Jennifer [1 ]
Zhang, Yongbin [1 ]
Mohan, Radhe [1 ]
Dong, Lei [1 ]
机构
[1] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
auto-contouring; deformable image registration; adaptive radiotherapy; image-guided radiotherapy; auto-segmentation;
D O I
10.1016/j.ijrobp.2008.05.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. Methods and Materials: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. Results: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. Conclusion: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended. (C) 2008 Elsevier Inc.
引用
收藏
页码:210 / 219
页数:10
相关论文
共 50 条
  • [21] Automatic Assessment of Transcatheter Aortic Valve Implantation Results on Four-Dimensional Computed Tomography Images Using Artificial Intelligence
    Busto, Laura
    Veiga, Cesar
    Gonzalez-Novoa, Jose A.
    Campanioni, Silvia
    Juan-Salvadores, Pablo
    Diaz, Victor Alfonso Jimenez
    Baz, Jose Antonio
    Alba-Castro, Jose Luis
    Kutting, Maximilian
    Iniguez, Andres
    BIOENGINEERING-BASEL, 2023, 10 (10):
  • [22] Evaluation of mitral chordae tendineae length using four-dimensional computed tomography
    Mori, Takuya
    Matsushita, Satoshi
    Morita, Terumasa
    Abudurezake, Abulaiti
    Mochizuki, Junji
    Amano, Atsushi
    WORLD JOURNAL OF CARDIOLOGY, 2024, 16 (05): : 274 - 281
  • [23] Systematic evaluation of lung tumor motion using four-dimensional computed tomography
    Sarudis, Sebastian
    Hauer, Anna Karlsson
    Nyman, Jan
    Back, Anna
    ACTA ONCOLOGICA, 2017, 56 (04) : 525 - 530
  • [24] Initial evaluation of a four-dimensional computed tomography system, using a programmable motor
    Simon, Luc
    Giraud, Philippe
    Servois, Vincent
    Rosenwald, Jean-Claude
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (04): : 50 - 65
  • [25] Automatic Prostate Segmentation in Cone-Beam Computed Tomography Images using Rigid Registration
    Boydev, Christine
    Pasquier, David
    Derraz, Foued
    Peyrodie, Laurent
    Taleb-Ahmed, Abdelmalik
    Thiran, Jean-Philippe
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3993 - 3997
  • [26] Deformable Image Registration of Four-Dimensional Computed Tomography Demonstrates Significantly Less Renal Motion in Children Under General Anaesthetic Compared to Children Who Are Not
    Lavan, N.
    McQuaid, D.
    Smyth, G.
    Vaidya, S.
    Saran, F. H.
    Mandeville, H.
    PEDIATRIC BLOOD & CANCER, 2018, 65 : S412 - S412
  • [27] Adjoint image warping using multivariate splines with application to four-dimensional computed tomography
    Renders, Jens
    Sijbers, Jan
    De Beenhouwer, Jan
    MEDICAL PHYSICS, 2021, 48 (10) : 6362 - 6374
  • [28] Fast four-dimensional cone-beam computed tomography reconstruction using deformable convolutional networks
    Jiang, Zhuoran
    Chang, Yushi
    Zhang, Zeyu
    Yin, Fang-Fang
    Ren, Lei
    MEDICAL PHYSICS, 2022, 49 (10) : 6461 - 6476
  • [29] Comparison of intensity-modulated radiotherapy planning based on manual and automatically generated contours using deformable image registration in four-dimensional computed tomography of lung cancer patients
    Weiss, Elisabeth
    Wijesooriya, Krishni
    Ramakrishnan, Viswanathan
    Keall, Paul J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 572 - 581
  • [30] Respiratory motion of adrenal gland metastases: Analyses using four-dimensional computed tomography images
    Chen, Bing
    Hu, Yong
    Liu, Jin
    Cao, An-Ning
    Ye, Lu-Xi
    Zeng, Zhao-Chong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 : 54 - 58