Comparison of the sensitivities of 5 different computed tomography scanners for the assessment of the progression of pulmonary emphysema - A phantom study

被引:40
|
作者
Stoel, BC
Bakker, ME
Stolk, J
Dirksen, A
Stockley, RA
Piitulainen, E
Russi, EW
Reiber, JHC
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Pulmonol, NL-2333 ZA Leiden, Netherlands
[3] Gentofte Univ Hosp, Dept Resp Med, Hellerup, Denmark
[4] Queen Elizabeth Hosp, Dept Resp Med, Birmingham B15 2TH, W Midlands, England
[5] Malmo Univ Hosp, Dept Pulm Med, Malmo, Sweden
[6] Univ Zurich Hosp, Pulmonol Div, CH-8091 Zurich, Switzerland
关键词
emphysema; computed tomography; quantitative; lung densitometry;
D O I
10.1097/01.rli.0000091842.82062.a3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the sensitivities of 5 different computed tomography scanners (4 multislice CT [MSCT] and 1 single-slice CT) in the assessment of the progression of pulmonary emphysema. Methods: A Perspex cylinder phantom was constructed containing small pieces of polythene foam with densities representative of lung. Changing the cylinder's volume simulated subtle lung density changes. The sensitivity to density changes was defined by the variation in the residual errors from the linear regression line between time and density. Results: The single-slice CT scanner was significantly less sensitive to density changes than MSCT scanners. Also, among MSCT scanners, small but significant differences were found when the standardized acquisition protocol was used. Conclusions: Considering the large sensitivity differences between single- and multislice CT scanners, we would recommended using MSCT scanners in clinical multicenter trials in emphysema. The protocol standardization of MSCT scanners can still be further improved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] A phantom study for the comparison of different brands of computed tomography scanners and software packages for endovascular aneurysm repair sizing and planning
    Velu, Juliette F.
    Jebbink, Erik Groot
    de Vries, Jean-Paul P. M.
    van der Palen, Job A. M.
    Slump, Cornelis H.
    Geelkerken, Robert H.
    [J]. VASCULAR, 2018, 26 (02) : 198 - 202
  • [2] Variability in densitometric assessment of pulmonary emphysema with computed tomography
    Bakker, ME
    Stolk, J
    Putter, H
    Shaker, SB
    Parr, DG
    Piitulainen, E
    Russi, EW
    Dirksen, A
    Stockley, RA
    Reiber, JHC
    Stoel, BC
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (12) : 777 - 783
  • [3] Quantitative assessment of nonsolid pulmonary nodule volume with computed tomography in a phantom study
    Gavrielides, Marios A.
    Berman, Benjamin P.
    Supanich, Mark
    Schultz, Kurt
    Li, Qin
    Petrick, Nicholas
    Zeng, Rongping
    Siegelman, Jenifer
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (06) : 623 - 635
  • [4] Comparison of different computed tomography scanning methods for quantifying emphysema
    Nishimura, K
    Murata, K
    Yamagishi, M
    Itoh, H
    Ikeda, A
    Tsukino, M
    Koyama, H
    Sakai, N
    Mishima, M
    Izumi, T
    [J]. JOURNAL OF THORACIC IMAGING, 1998, 13 (03) : 193 - 198
  • [5] COMPARISON OF COMPUTED TOMOGRAPHY SCANNERS AMONG VARIOUS MODELS OF DIFFERENT VENDORS
    Kumar, Pratik
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (01) : 75 - +
  • [6] EXPIRATORY COMPUTED-TOMOGRAPHY FOR ASSESSMENT OF SUSPECTED PULMONARY-EMPHYSEMA
    KNUDSON, RJ
    STANDEN, JR
    KALTENBORN, WT
    KNUDSON, DE
    REHM, K
    HABIB, MP
    NEWELL, JD
    [J]. CHEST, 1991, 99 (06) : 1357 - 1366
  • [7] Quantitative computed tomography assessment of lung structure and function in pulmonary emphysema
    Madani, A
    Keyzer, C
    Gevenois, PA
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (04) : 720 - 730
  • [8] VOLUME ASSESSMENT ACCURACY IN COMPUTED TOMOGRAPHY: A PHANTOM STUDY
    Prionas, N. D.
    Ray, S.
    Boone, J. M.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (01) : 120 - 120
  • [9] Volume assessment accuracy in computed tomography: a phantom study
    Prionas, Nicolas D.
    Ray, Shonket
    Boone, John M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 168 - 180
  • [10] Pulmonary Emphysema Subtypes on Computed Tomography: The MESA COPD Study
    Smith, Benjamin M.
    Austin, John H. M.
    Newell, John D., Jr.
    D'Souza, Belinda M.
    Rozenshtein, Anna
    Hoffman, Eric A.
    Ahmed, Firas
    Barr, R. Graham
    [J]. AMERICAN JOURNAL OF MEDICINE, 2014, 127 (01): : 94.e7 - 94.e23