Variability in densitometric assessment of pulmonary emphysema with computed tomography

被引:69
|
作者
Bakker, ME
Stolk, J
Putter, H
Shaker, SB
Parr, DG
Piitulainen, E
Russi, EW
Dirksen, A
Stockley, RA
Reiber, JHC
Stoel, BC
机构
[1] Leiden Univ, Med Ctr, Dept Radiol C2S, Div Image Proc, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Pulmonol, NL-2333 ZA Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Med Stat, NL-2333 ZA Leiden, Netherlands
[4] Gentofte Univ Hosp, Dept Resp Med, Hellerup, Denmark
[5] Queen Elizabeth Hosp, Dept Resp Med, Birmingham B15 2TH, W Midlands, England
[6] Malmo Univ Hosp, Dept Pulm Med, Malmo, Sweden
[7] Univ Zurich Hosp, Pulmonol Div, CH-8091 Zurich, Switzerland
关键词
densitometry; CT; reproducibility;
D O I
10.1097/01.rli.0000186418.31139.21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The objectives of this Study were to investigate whether computed tomography (CT) densitometry can be applied consistently in different centers; and to evaluate the reproducibility of densitometric quantification of emphysema by assessment of different sources of variation, ie, intersite, interscan and inter- and intraobserver variability, in comparison with intersubject variability. Materials and Methods: In 5 different hospitals, 119 patients with emphysema were scanned Using standardized protocols. In each site, an observer performed a quantitative densitometric analysis; (including blood recalibration) on the corresponding patient group (n = 23-25) and one observer analyzed the entire group of 119 patients. After several months, the latter observer analyzed all data for a second time. Subsequently, different sources of variation were assessed by variance component analysis with and without volume correction of the data. Results: Inter- and intraobserver variability marginally contributes to the total variability (< 0.001%). The interscan variability was 0.02% of the total variation after application of volume correction. The intersite variability was 48% as a result of one deviating CT scanner. Air recalibration normalized deviating air densities in CT scanners. Within sites, the intersubject variability ranged between 93% and 99% based on the analysis of 2 subsequent CT scans of the patients.
引用
收藏
页码:777 / 783
页数:7
相关论文
共 50 条
  • [1] Computed Tomography Biomarkers of Pulmonary Emphysema
    Kirby, Miranda
    Coxson, Harvey O.
    [J]. COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2013, 10 (04) : 547 - 550
  • [2] EXPIRATORY COMPUTED-TOMOGRAPHY FOR ASSESSMENT OF SUSPECTED PULMONARY-EMPHYSEMA
    KNUDSON, RJ
    STANDEN, JR
    KALTENBORN, WT
    KNUDSON, DE
    REHM, K
    HABIB, MP
    NEWELL, JD
    [J]. CHEST, 1991, 99 (06) : 1357 - 1366
  • [3] Quantitative computed tomography assessment of lung structure and function in pulmonary emphysema
    Madani, A
    Keyzer, C
    Gevenois, PA
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (04) : 720 - 730
  • [4] Influence of calibration on densitometric studies of emphysema progression using computed tomography
    Parr, DG
    Stoel, BC
    Stolk, J
    Nightingale, PG
    Stockley, RA
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (08) : 883 - 890
  • [5] COMPUTED-TOMOGRAPHY IN PULMONARY-EMPHYSEMA
    GODDARD, PR
    NICHOLSON, EM
    LASZLO, G
    WATT, I
    [J]. CLINICAL RADIOLOGY, 1982, 33 (04) : 379 - 387
  • [6] THE HIGH RESOLUTION COMPUTED TOMOGRAPHY IN ASSESSMENT OF PATIENTS WITH EMPHYSEMA FOLLOWING PULMONARY REHABILITATION
    Wang, J-S
    [J]. RESPIROLOGY, 2015, 20 : 10 - 10
  • [7] Quantitative Emphysema Assessment of Pulmonary Function Impairment by Computed Tomography in Chronic Obstructive Pulmonary Disease
    Wang, Guangli
    Wang, Lin
    Ma, Zhenshen
    Zhang, Chengqi
    Deng, Kai
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 171 - 175
  • [8] COMPUTED-TOMOGRAPHY AND DENSITOMETRIC PATTERN OF PULMONARY-LESIONS
    SCHEID, KF
    LISSNER, J
    BLAHA, H
    GEBAUER, A
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1981, 134 (04): : 357 - 363
  • [9] LIMITATIONS OF COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF EMPHYSEMA
    MILLER, RR
    MULLER, NL
    VEDAL, S
    MORRISON, NJ
    STAPLES, CA
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (04): : 980 - 983
  • [10] Role of computed tomography in quantitative assessment of emphysema
    Choromanska, Agnieszka
    Macura, Katarzyna J.
    [J]. POLISH JOURNAL OF RADIOLOGY, 2012, 77 (01) : 28 - 36