Genetic and geometric optimization of three-dimensional radiation therapy treatment planning

被引:90
|
作者
Ezzell, GA [1 ]
机构
[1] WAYNE STATE UNIV,DETROIT,MI 48201
关键词
optimization; genetic algorithm; 3D treatment planning;
D O I
10.1118/1.597660
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The thesis of this report is that potentially useful treatment beams can be chosen based on geometric heuristics and that a genetic algorithm (GA) can be constructed to find an optimal combination of beams based on a formal objective function. The paper describes the basic principles of a GA and the particular implementation developed. The code represents each plan in the population as two paired lists compirsed of beam identifiers and relative weights. Reproduction operators, which mimic sexual reproduction with crossover, mutation, cloning, spontaneous generation, and death, manipulate the lists to grow optimal plans. The necessary gene pool is created by software modules which generate beams, distribute calculation points, obtain clinical constraints, add wedges, and calculate doses. The code has been tested on a set of artificial patients and on four clinical cases: prostate, pancreas, esophagus, and glomus. All demonstrated consistent results, indicating that the code is a reliable optimizer. Additional experiments compared the results for a full set of open beams to the geometrically selected set and the GA code with simulated annealing. Geometric selection of beam directions did not significantly compromise optimization quality. Compared to simulated annealing, the genetic algorithm was equally able to optimize the objective function, and calculations suggest it may be the faster method when the number of beams to be considered exceeds approximately 70. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 50 条
  • [21] Three-dimensional conformal radiation therapy for ependymoma
    Merchant, Thomas E.
    [J]. CHILDS NERVOUS SYSTEM, 2009, 25 (10) : 1261 - 1268
  • [22] Three-dimensional dose verification for radiation therapy
    Guo, P.
    Adamovics, J.
    Oldham, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S710 - S711
  • [23] Three-dimensional approach of breast radiation therapy
    Huibers, M
    Berfelo, S
    de Groot, L
    Valkering, I
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S464 - S464
  • [24] Three-dimensional conformal radiation therapy for ependymoma
    Thomas E. Merchant
    [J]. Child's Nervous System, 2009, 25 : 1261 - 1268
  • [25] Three-dimensional conformal radiation therapy in gliomas
    Kurtman, C
    Akfirat, C
    Andrieu, MN
    Hicsonmez, A
    [J]. EXPERIMENTAL ONCOLOGY, 2003, 25 (04) : 310 - 312
  • [26] Presurgical Virtual Three-Dimensional Treatment Planning
    Farronato, Giampietro
    Giannini, Lucia
    Galbiati, Guido
    Mortellaro, Carmen
    Maspero, Cinzia
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : 820 - 823
  • [27] Three-dimensional treatment planning for prosthetic rehabilitation
    Besimo, CE
    Rohner, HP
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (01) : 81 - 87
  • [28] A three-dimensional model-based segmentation system for the radiation oncology treatment planning
    Cardenas, C
    Gibou, F
    Levy, D
    Boyer, A
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1290 - 1290
  • [29] The dosimetric verification of commercial two-and three-dimensional radiation treatment planning systems
    Kilį, Ayhan
    Özkan, Lütfi
    Engin, Kayihan
    [J]. Turkish Journal of Medical Sciences, 2002, 32 (02) : 133 - 137
  • [30] GEOMETRIC MODELING OF THREE-DIMENSIONAL OBJECTS IN AUTOMATED PLANNING SYSTEMS.
    Pokhvalinskiy, A.B.
    Visikirskiy, V.A.
    [J]. Soviet Journal of Automation and Information Sciences (English translation of Avtomatyka), 1985, 18 (06): : 20 - 23