Contrast-enhancement, image noise and dual-energy simulations for quantum-counting clinical CT

被引:11
|
作者
Kappler, S. [1 ]
Niederloehner, D. [1 ]
Stierstorfer, K. [1 ]
Flohr, T. [1 ]
机构
[1] Siemens AG, Healthcare Sector, D-91301 Forchheim, Germany
关键词
CT; CTDE; DET; SYS; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.843650
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The spectral sensitivity of quantum-counting detectors promises increased contrast-to-noise ratios and dual-energy capabilities for Computed Tomography (CT). In this article we quantify the benefits as well as the conceptual limitations of this technology under realistic clinical conditions. We present detailed simulations of a CT system with CdZnTe-based quantum-counting detector and compare to a conventional energy-integrating detector with Gd2O2S scintillator. Detector geometries and pixel layouts are adapted to specific requirements of clinical CT and its high-flux environment. The counting detector is realized as a two-threshold counter. An image-based method is used to adapt thresholds and data weights optimizing contrasts and image noise with respect to the typical spectra provided by modern high-power tungsten anode X-ray tubes. We consider the case of moderate X-ray fluxes and compare contrasts and image noise at same patient dose and image sharpness. We find that the spectral sensitivity of such a CT system offers dose reduction potentials of 31.5% (9.2%) maintaining Iodine-water contrast-to-noise ratios at 120kVp (80kVp). The improved contrast-to-noise ratios result mainly from improved contrasts and not from reduced image noise. The presence of fluorescence effects in the sensor material is the reason why image noise levels are not significantly reduced in comparison to energy-integrating systems. Dual-energy performance of quantum-counting single-source CT in terms of bone-Iodine separation is found to be somewhat below the level of today's dual-source CT devices with optimized pre-filtration of the X-ray beams.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Noise Suppression for Dual-Energy CT Through Entropy Minimization
    Petrongolo, Michael
    Zhu, Lei
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) : 2286 - 2297
  • [22] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299
  • [23] Noise Suppression for Dual-Energy CT Through Entropy Minimization
    Petrongolo, M.
    Niu, T.
    Zhu, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 408 - 408
  • [24] Detection of Renal Lesion Enhancement with Dual-Energy Multidetector CT
    Neville, Amy M.
    Gupta, Rajan T.
    Miller, Chad M.
    Merkle, Elmar M.
    Paulson, Erik K.
    Boll, Daniel T.
    [J]. RADIOLOGY, 2011, 259 (01) : 173 - 183
  • [25] Dual-Energy CBCT Imaging for Metal Artifact Reduction and Contrast Enhancement
    Li, H.
    Giles, W.
    Ren, L.
    Bowsher, J.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 4017 - 4017
  • [26] Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    McCollough, Cynthia H.
    [J]. RADIOLOGY, 2015, 276 (02) : 562 - 570
  • [27] Dual-energy CT: technical considerations and clinical applications
    Fernandez-Perez, G. C.
    Fraga Pineiro, C.
    Onate Miranda, M.
    Diez Blanco, M.
    Mato Chain, J.
    Collazos Martinez, M. A.
    [J]. RADIOLOGIA, 2022, 64 (05): : 445 - 455
  • [28] Generation of Dual-Energy CT Image Dataset From Single-Energy CT Image Dataset
    Dong, Y.
    Huo, J.
    Wang, X.
    Wang, P.
    Zhu, X.
    Feng, Y.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [29] A method for material decomposition in dual-energy contrast enhancement digital mammography
    Kahani, M.
    Kamali-asl, A.
    Ghadiri, H.
    Hashemi, S.
    [J]. MEASUREMENT, 2016, 88 : 87 - 95
  • [30] Clinical Implementation of Dual-Energy CT for Gastrointestinal Imaging
    Mileto, Achille
    Ananthakrishnan, Lakshmi
    Morgan, Desiree E.
    Yeh, Benjamin M.
    Marin, Daniele
    Kambadakone, Avinash R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (03) : 651 - 662