Determination of fluvoxamine and its metabolite fluvoxamino acid by liquid-liquid extraction and column-switching high-performance liquid chromatography

被引:16
|
作者
Yasui-Furukori, N
Inoue, Y
Kaneko, S
Otani, K
机构
[1] Hirosaki Univ, Sch Med, Dept Neuropsychiat, Hirosaki, Aomori 0368562, Japan
[2] Mitsubishi Pharma, Pharmaceut Technol Div, Fukuoka, Japan
[3] Yamagata Univ, Sch Med, Dept Neuropsychiat, Yamagata 99023, Japan
关键词
fluvoxamine; fluvoxamino acid; HPLC; column-switching;
D O I
10.1016/j.jpba.2004.09.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study describes a new simultaneous determination of fluvoxamine and fluvoxamino acid by automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1.5 ml of plasma using chloroform-toluene (15:85, v/v), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C18 analytical column for separation. The mobile phase for separation consisted of phosphate buffer (0.02 M, pH 4.6), acetonitrile and perchloric acid (60%) (62.4:37.5:0.1, v/v/v) and was delivered at a flow rate of 0.6 ml/min. The peak was detected using a UV detector set at 254 nm. The method was validated for the concentration range 0.8-153.6 ng/ml for fluvoxamine and 0.6-115.2 ng/ml for fluvoxamino acid, and their good linearity (r > 0.998) were confirmed. Intra-day coefficient variations (CVs) for fluvoxamine and fluvoxamino acid were less than 6.6 and 6.0%, respectively. Inter-day CVs for corresponding compounds were 6.3 and 6.5%, respectively. Relative errors ranged from -18 to 9% and mean recoveries were 96-100%. The limit of quantification was 1.2 and 0.9 ng/ml for fluvoxamine and fluvoxamino acid, respectively. This method shows successful application for pharmacokinetic studies and therapeutic drug monitoring. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [21] DETERMINATION OF ALFUZOSIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    CARLUCCI, G
    DIGIUSEPPE, E
    MAZZEO, P
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (18): : 3989 - 3997
  • [22] DETERMINATION OF CLOCAPRAMINE AND ITS METABOLITES IN PLASMA BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    KOJIMA, N
    OHKURA, Y
    ANALYTICAL SCIENCES, 1990, 6 (03) : 367 - 370
  • [23] Quantification of ephedrines in urine by column-switching high-performance liquid chromatography
    Gmeiner, G
    Geisendorfer, T
    Kainzbauer, J
    Nikolajevic, M
    Tausch, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 768 (02): : 215 - 221
  • [24] Determination of finasteride in human plasma by liquid-liquid extraction and high-performance liquid chromatography
    Ptácek, P
    Macek, J
    Klíma, J
    JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02): : 305 - 310
  • [25] Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method
    Kumihashi, Mitsuru
    Ameno, Kiyoshi
    Shibayama, Takayuki
    Suga, Keisuke
    Miyauchi, Hiroshi
    Jamal, Mostofa
    Wang, Weihuan
    Uekita, Ikuo
    Ijiri, Iwao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 180 - 183
  • [26] Determination of a new atypical antipsychotic agent perospirone and its metabolite in human plasma by automated column-switching high-performance liquid chromatography
    Yasui-Furukori, N
    Inoue, Y
    Tateishi, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 239 - 245
  • [27] Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma
    Ban, EM
    Maeng, JE
    Woo, JS
    Kim, CK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 230 - 235
  • [28] High-performance liquid chromatography with a column-switching system and capillary electrophoresis for the determination of ibuprofen in plasma
    Kang, SH
    Chang, SY
    Do, KC
    Chi, SC
    Chung, DS
    JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2): : 153 - 160
  • [29] Automated column-switching high-performance liquid chromatography for the determination of aflatoxin M1
    Simon, P
    Delsaut, P
    Lafontaine, M
    Morele, Y
    Nicot, T
    JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2): : 95 - 104
  • [30] DETERMINATION OF PLASMA ADENOSINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING AND FLUOROMETRIC DETECTION
    NITHIPATIKOM, K
    MIZUMURA, T
    GROSS, GJ
    ANALYTICAL BIOCHEMISTRY, 1994, 223 (02) : 280 - 284