Commentary to 'Correction of the slope-intercept method for the measurement of glomerular filtration rate'

被引:2
|
作者
Jodal, Lars [1 ]
Brochner-Mortensen, Jens [1 ]
机构
[1] Aalborg Univ Hosp, Dept Nucl Med, DK-9100 Aalborg, Denmark
关键词
CHILDREN;
D O I
10.1097/MNM.0000000000000269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:407 / 408
页数:3
相关论文
共 50 条
  • [21] Agreement between Chantler and Brochner-Mortensen corrections of the slope-intercept method of glomerular filtration rate (GFR) measurement at various levels of renal function in adult patients
    Arsos, G.
    Moralidis, E.
    Karavida, N.
    Boussios, N.
    Georga, S.
    Papagianni, A.
    Karakatsanis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S367 - S367
  • [22] Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: Use of two independent markers and an independent arbiter
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) : 711 - 718
  • [23] Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
    Geist, Barbara Katharina
    Diemling, Markus
    Staudenherz, Anton
    MEDICAL PRINCIPLES AND PRACTICE, 2016, 25 (04) : 368 - 373
  • [24] A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements
    Porter, Charlotte A.
    Bradley, Kevin M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (05) : 465 - 468
  • [25] A new quality control parameter for slope-intercept GFR measurement
    Holness, J. L.
    Warwick, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S841 - S841
  • [26] Age-specific normal reference ranges for 99mTc-DTPA glomerular filtration rate to use with two-sample slope-intercept method and Jodal Brochner-Mortensen correction
    Gautam, Sijan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (04) : 1331 - 1340
  • [27] Age-specific normal reference ranges for 99mTc-DTPA glomerular filtration rate to use with two-sample slope-intercept method and Jodal Brochner-Mortensen correction
    Sijan Gautam
    Physical and Engineering Sciences in Medicine, 2021, 44 : 1331 - 1340
  • [28] COMPARISON OF MEASUREMENT OF GLOMERULAR-FILTRATION RATE BY SINGLE SAMPLE, PLASMA DISAPPEARANCE SLOPE INTERCEPT AND OTHER METHODS
    TEPE, PG
    TAUXE, WN
    BAGCHI, A
    REZENDE, P
    KRISHNAIAH, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 13 (01): : 28 - 31
  • [29] COMPARISON OF MEASUREMENT OF GLOMERULAR-FILTRATION RATE BY SINGLE SAMPLE, PLASMA DISAPPEARANCE SLOPE INTERCEPT AND OTHER METHODS
    TAUXE, WN
    TEPE, PG
    BAGCHI, A
    KRISHNAIAH, PR
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 928 - 928
  • [30] Glomerular filtration rate (GFR) measurement with Cr-51-EDTA: comparison of the slope-intercept 2-sample method with the 10-sample kinetic plasma clearance analysis in a representative cohort of patients
    Arsos, G.
    Manou, E.
    Miserlis, G.
    Sioulis, A.
    Tsechelidis, I.
    Sachpekidis, C.
    Tsakiris, D.
    Karatzas, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S602 - S602