Dissolved Oxygen PWM Control and Oxygen Uptake Rate Estimation using Kalman Filter in Activated Sludge Systems

被引:0
|
作者
Silva, Francisco J. S. [1 ]
Catunda, Sebastian Y. C. [1 ]
Fonseca Neto, Joao V. [1 ]
van Haandel, Adrianus C. [2 ]
机构
[1] Univ Fed Maranhao, Sao Luis, MA, Brazil
[2] Univ Fed Campina Grande, Campina Grande, Brazil
来源
2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS | 2010年
关键词
oxygen uptake rate; activated sludge; dissolved oxygen; estimation; measurement; Kalman Filter; PWM; wastewater treatment;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurement and utilization of the oxygen uptake rate (OUR), or respiration rate, is very important in biological wastewater treatment process. It provides information about the biological activity and can indicate the presence of the toxic elements able to corrupt the system. An alternative to the lack of OUR sensors is to use computer codes as software sensors for the estimation of respirometric activity, based on dissolved oxygen (DO) measurements. In this paper the OUR is estimated using Kalman Filter as a software sensor and the DO concentration is controlled by aerators of on-off type triggered by pulse wide modulation. Simulation and experimental estimations are performed on a bench scale aerobic reactor.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Dissolved oxygen control of the activated sludge wastewater treatment process using stable adaptive fuzzy control
    Coelho Belchior, Carlos Alberto
    Matos Araujo, Rui Alexandre
    Cardoso Landeck, Jorge Afonso
    COMPUTERS & CHEMICAL ENGINEERING, 2012, 37 : 152 - 162
  • [42] Comparison of Control Strategies for Dissolved Oxygen Control in Activated Sludge Wastewater Treatment Process
    Akyurek, Evrim
    Yuceer, Mehmet
    Atasoy, Ilknur
    Berber, Ridvan
    19TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2009, 26 : 1197 - 1201
  • [43] Measurement and validity of oxygen uptake as an activated sludge process control parameter
    Edwards, G.L.
    Sherrard, J.H.
    Journal of the Water Pollution Control Federation, 1982, 54 (12): : 1546 - 1552
  • [45] EFFECT OF HIGH DISSOLVED-OXYGEN CONCENTRATION IN ACTIVATED-SLUDGE SYSTEMS
    CHAPMAN, TD
    MATSCH, LC
    ZANDER, EH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1976, 48 (11): : 2486 - 2510
  • [46] MPC advanced control of dissolved oxygen in an activated sludge wastewater treatment plant
    Harja, Gabriel
    Vlad, Grigore
    Nascu, Joan
    PROCEEDING OF 2016 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR), 2016, : 269 - 274
  • [47] Robust Generic Model Control for dissolved oxygen in activated sludge wastewater plant
    Aguilar-Lopez, R.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2008, 22 (01) : 71 - 79
  • [48] MONITORING AND AUTOMATIC CONTROL OF DISSOLVED OXYGEN LEVEL IN ACTIVATED-SLUDGE PLANTS
    BRIGGS, R
    JONES, KJ
    OATEN, AB
    EFFLUENT & WATER TREATMENT JOURNAL, 1967, 7 (03): : 149 - &
  • [49] MONITORING AND AUTOMATIC CONTROL OF DISSOLVED OXYGEN LEVEL IN ACTIVATED-SLUDGE PLANTS
    BRIGGS, R
    JONES, KJ
    OATEN, AB
    EFFLUENT & WATER TREATMENT JOURNAL, 1967, 7 (02): : 67 - &
  • [50] EVALUATION OF OXYGEN-UPTAKE RATE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER - RESPONSE
    CHANDRA, S
    MINES, RO
    SHERRARD, JH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1989, 61 (01): : 102 - 102