Influence of orientation on the contrast of high-angle annular dark-field images of silicon

被引:40
|
作者
Klenov, Dmitri O.
Findlay, Scott D.
Allen, Leslie J.
Stemmer, Susanne
机构
[1] Univ Calif Santa Barbara, Dept Mat, Santa Barbara, CA 93106 USA
[2] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
来源
PHYSICAL REVIEW B | 2007年 / 76卷 / 01期
关键词
D O I
10.1103/PhysRevB.76.014111
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Atom column intensities of silicon single crystals oriented along different crystallographic orientations are compared in experimental and simulated high-angle annular dark-field images in scanning transmission electron microscopy. The intensity of a background, measured between the columns, is also evaluated and found to be largely independent of the column spacing. The contrast is lower in the experiments, and it has been suggested previously that this follows because the background is higher in the experiments. We explore the extent to which the comparison of experimental atom column intensities with image simulations is aided by subtraction of the background for these data. We also explore an alternative view: simple simulations overestimate the contrast because spatial incoherence and associated instabilities are not taken into account. The results do not distinguish between these approaches, which need not be in opposition, and we describe experiments which might further clarify matters.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Can high-angle annular dark field scattering be represented by a local operator?
    Rez, P
    ULTRAMICROSCOPY, 2000, 81 (3-4) : 195 - 202
  • [42] The structure of an Al-Ni-Co pentagonal quasicrystal studied by high-angle annular detector dark-field electron microscopy
    Hiraga, K
    Ohsuna, T
    Nishimura, S
    PHILOSOPHICAL MAGAZINE LETTERS, 2001, 81 (02) : 123 - 127
  • [43] Counting Tm dopant atoms around GaN dots using high-angle annular dark field images
    Rouviere, J-L
    Okuno, H.
    Jouneau, P. H.
    Bayle-Guillemaud, P.
    Daudin, B.
    17TH INTERNATIONAL CONFERENCE ON MICROSCOPY OF SEMICONDUCTING MATERIALS 2011, 2011, 326
  • [44] Simulation of atomic-scale high-angle annular dark field scanning transmission electron microscopy images
    Yamazaki, T
    Watanabe, K
    Recnik, A
    Ceh, M
    Kawasaki, M
    Shiojiri, M
    JOURNAL OF ELECTRON MICROSCOPY, 2000, 49 (06): : 753 - 759
  • [45] DYNAMIC THEORY OF HIGH-ANGLE ANNULAR-DARK-FIELD STEM LATTICE IMAGES FOR A GE/SI INTERFACE
    WANG, ZL
    COWLEY, JM
    ULTRAMICROSCOPY, 1990, 32 (03) : 275 - 289
  • [46] Electron beam-specimen interactions and their effect on high-angle annular dark-field imaging of dopant atoms within a crystal
    Mendis, B. G.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2010, 66 : 407 - 420
  • [47] Composite structure of liquid crystal/polymer nanotubes revealed by high-angle annular dark-field scanning transmission electron microscopy
    Schaper, Andreas K.
    Kurata, Hiroki
    Yoshioka, Taiyo
    Tsuji, Masaki
    MICROSCOPY AND MICROANALYSIS, 2007, 13 (05) : 336 - 341
  • [48] Direct imaging of Guinier-Preston zones by high-angle annular detector dark-field scanning transmission electron microscopy
    Konno, TJ
    Kawasaki, M
    Hiraga, K
    JOURNAL OF ELECTRON MICROSCOPY, 2001, 50 (02): : 105 - 111
  • [49] Limitations in through-focus depth sectioning in non-aberration corrected high-angle annular dark-field imaging
    Klenov, Dmitri O.
    Stemmer, Susanne
    Japanese Journal of Applied Physics, Part 2: Letters, 2006, 45 (20-23):
  • [50] Limitations in through-focus depth sectioning in non-aberration corrected high-angle annular dark-field imaging
    Klenov, Dmitri O.
    Stemmer, Susanne
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (20-23): : L602 - L604