Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths

被引:106
|
作者
Dam, JS [1 ]
Pedersen, CB
Dalgaard, T
Fabricius, PE
Aruna, P
Andersson-Engels, S
机构
[1] Bang & Olufsen Medicom AS, DK-7600 Struer, Denmark
[2] Lund Inst Technol, Dept Phys, SE-22100 Lund, Sweden
[3] Anna Univ, Madras 600025, Tamil Nadu, India
关键词
D O I
10.1364/AO.40.001155
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a compact, fast, and versatile fiber-optic probe system for real-time determination of tissue optical properties from spatially resolved continuous-wave diffuse reflectance measurements. The system collects one set of reflectance data from six source-detector distances at four arbitrary wavelengths with a maximum overall sampling rate of 100 Hz. Multivariate calibration techniques based on two-dimensional polynomial fitting are employed to extract and display the absorption and reduced scattering coefficients in real-time mode. The four wavelengths of the current configuration are 660, 785, 805, and 974 nm, respectively. Cross-validation tests on a 6 x 7 calibration matrix of Intralipid-dye phantoms showed that the mean prediction error at, e.g., 785 nm was 2.8% for the absorption coefficient and 1.3% for the reduced scattering coefficient. The errors are relative to the range of the optical properties of the phantoms at 785 nm, which were 0-0.3/cm for the absorption coefficient and 6-16/cm for the reduced scattering coefficient. Finally, we also present and discuss results from preliminary skin tissue measurements. (C) 2001 Optical Society of America
引用
收藏
页码:1155 / 1164
页数:10
相关论文
共 50 条
  • [41] In vivo fiber-optic fluorescent sensor for real-time pH monitoring of tumor microenvironment
    Li, Zesen
    Lan, Ni
    Cheng, Zhongyuan
    Jin, Fangzhou
    Song, Enlai
    Xu, Zhiyuan
    Zhang, Yongkang
    Feng, You-Zhen
    Cai, Xiangran
    Ran, Yang
    Guan, Bai-Ou
    CHEMICAL ENGINEERING JOURNAL, 2024, 493
  • [42] Real-time structural health monitoring using a novel fiber-optic accelerometer system
    Kim, Dae-Hyun
    Feng, Maria Q.
    IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 536 - 543
  • [43] Real-time immunoassays using fiber-optic long-period grating sensors
    Tran, TA
    Bhatia, V
    DAlberto, T
    Murphy, KA
    Claus, RO
    BIOMEDICAL SENSING, IMAGING, AND TRACKING TECHNOLOGIES I, 1996, 2676 : 165 - 170
  • [44] Diffuse reflectance spectroscopy of epithelial tissue with a smart fiber-optic probe
    Yu, Bing
    Shah, Amy
    Nagarajan, Vivek K.
    Ferris, Daron G.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (03): : 675 - 689
  • [45] A fiber-optic approach for in vivo minimally-invasive study of tissue optical properties
    Ilev, IK
    Waynant, RW
    Byrnes, KR
    Anders, J
    OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS IV, 2004, 5317 : 147 - 150
  • [46] Optical properties of modified Bragg fiber-optic waveguides
    Kulchin, Yu N.
    Zinin, Yu A.
    Nagornyi, I. G.
    Voznesenskii, S. S.
    OPTICS AND SPECTROSCOPY, 2011, 111 (05) : 819 - 823
  • [47] Optical properties of modified Bragg fiber-optic waveguides
    Yu. N. Kulchin
    Yu. A. Zinin
    I. G. Nagornyi
    S. S. Voznesenskii
    Optics and Spectroscopy, 2011, 111 : 819 - 823
  • [48] The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems
    Hoerner, M.
    Hintenlang, D.
    MEDICAL PHYSICS, 2015, 42 (06) : 3262 - 3262
  • [49] Development of a Fiber-Optic Optical Coherence Tomography Probe for Intraocular Use
    Asami, Tetsu
    Terasaki, Hiroko
    Ito, Yasuki
    Sugita, Tadasu
    Kaneko, Hiroki
    Nishiyama, Junpei
    Namiki, Hajime
    Kobayashi, Masahiko
    Nishizawa, Norihiko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT568 - OCT574
  • [50] Time-resolved transmittance for the noninvasive determination of tissue optical properties
    De Nicola, S
    Falco, MD
    Lepore, M
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 272 - 281