Development of an activated carbon filter to remove NO2 and HONO in indoor air

被引:23
|
作者
Yo, Jun Young [1 ]
Park, Chan Jung [2 ]
Kim, Ki Yeong [3 ]
Son, Youn-Suk [4 ]
Kang, Choong-Min [5 ]
Wolfson, Jack M. [5 ]
Jung, In-Ha [4 ]
Lee, Sung-Joo [4 ]
Koutrakis, Petros [5 ]
机构
[1] Seoul Natl Univ Res Pk, Coway R&D Ctr, Air Dev Grp, Seoul 151919, South Korea
[2] Seoul Natl Univ Res Pk, Coway R&D Ctr, Dev Div, Seoul 151919, South Korea
[3] 3AC Co Ltd, R&D Ctr, Hwaseong Si 445902, Gyeonggi Do, South Korea
[4] Korea Atom Energy Res Inst, Res Div Ind & Environm, Jeongeup Si 580185, Jeollabuk Do, South Korea
[5] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Exposure Epidemiol & Risk Program, Boston, MA 02115 USA
基金
新加坡国家研究基金会;
关键词
HONO; NO2; Indoor air; Activated carbon filter; Air cleaner; IAQ; NITROUS-ACID; DIOXIDE; ADSORPTION; ASSOCIATION; PERFORMANCE; ENVIRONMENT; REDUCTION; CATALYSTS; POLLUTION; TOXICITY;
D O I
10.1016/j.jhazmat.2015.02.038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To obtain the optimum removal efficiency of NO2 and HONO by coated activated carbon (ACs), the influencing factors, including the loading rate, metal and non-metal precursors, and mixture ratios, were investigated. The NO removal efficiency (RE) for K, with the same loading (1.0 wt.%), was generally higher than for those loaded with Cu or Mn. The RE of NO2 was also higher when KOH was used as the K precursor, compared to other K precursors (KI, KNO3, and KMnO4). In addition, the REs by the ACs loaded with K were approximately 38-55% higher than those by uncoated ACs. Overall, the REs (above 95%) of HONO and NO with 3% KOH were the highest of the coated AC filters that were tested. Additionally, the REs of NO and HONO using a mixing ratio of 6 (2.5% PABA (p-aminobenzoic acid) + 6% H3PO4):4 (3% KOH) were the highest of all the coatings tested (both metal and non-metal). The results of this study show that AC loaded with various coatings has the potential to effectively reduce NO2 and HONO levels in indoor air. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 189
页数:6
相关论文
共 50 条
  • [31] Reaction of NO2 in air at room temperature with urea supported on pitch based activated carbon fiber
    Shirahama, N
    Mochida, I
    Korai, Y
    Choi, KH
    Enjoji, T
    Shimohara, T
    Yasutake, A
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2004, 52 (03) : 173 - 179
  • [33] Formation of indoor nitrous acid (HONO) by light-induced NO2 heterogeneous reactions with white wall paint
    Bartolomei, Vincent
    Soergel, Matthias
    Gligorovski, Sasho
    Gomez Alvarez, Elena
    Gandolfo, Adrien
    Strekowski, Rafal
    Quivet, Etienne
    Held, Andreas
    Zetzsch, Cornelius
    Wortham, Henri
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (15) : 9259 - 9269
  • [34] Formation of indoor nitrous acid (HONO) by light-induced NO2 heterogeneous reactions with white wall paint
    Vincent Bartolomei
    Matthias Sörgel
    Sasho Gligorovski
    Elena Gómez Alvarez
    Adrien Gandolfo
    Rafal Strekowski
    Etienne Quivet
    Andreas Held
    Cornelius Zetzsch
    Henri Wortham
    Environmental Science and Pollution Research, 2014, 21 : 9259 - 9269
  • [35] CFD-modelling of activated carbon fibers for indoor air purification
    Roegiers, Jelle
    Denys, Siegfried
    CHEMICAL ENGINEERING JOURNAL, 2019, 365 : 80 - 87
  • [36] Removal of Indoor Air Pollutants Using Activated Carbon-A Review
    Bhave, Prashant P.
    Yeleswarapu, Deepali
    GLOBAL CHALLENGES IN ENERGY AND ENVIRONMENT (ICEE 2018), 2020, : 65 - 75
  • [37] Indoor air particulate filtration onto activated carbon fiber media
    Lorimier, Celine
    Le Coq, Laurence
    Subrenat, Albert
    Le Cloirec, Pierre
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2008, 134 (02): : 126 - 137
  • [38] EVALUATION OF NO2 MEASUREMENT METHODS FOR INDOOR AIR-QUALITY APPLICATIONS
    SPICER, CW
    KENNY, DV
    WARD, GF
    BILLICK, IH
    LESLIE, NP
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1994, 44 (02): : 163 - 168
  • [39] Urban Grime Photochemistry and Its Interaction with Air Pollutants NO, NO2, and O3: A Source for HONO and NO2 Impacting OH in Urban Areas
    Mothes, Falk
    Hoffmann, Erik H.
    Herrmann, Hartmut
    ACS EARTH AND SPACE CHEMISTRY, 2023, 7 (11): : 2263 - 2274
  • [40] Indoor and outdoor air concentrations of BTEX and NO2:: correlation of repeated measurements
    Topp, R
    Cyrys, J
    Gebefügi, I
    Schnelle-Kreis, J
    Richter, K
    Wichmann, HE
    Heinrich, J
    JOURNAL OF ENVIRONMENTAL MONITORING, 2004, 6 (10): : 807 - 812