Validation of the New York University Langone Eye Test Application, a Smartphone-Based Visual Acuity Test

被引:5
|
作者
Iskander, Mina [1 ,2 ]
Hu, Galen [1 ]
Sood, Shefali [1 ]
Heilenbach, Noah [1 ]
Sanchez, Victor [1 ]
Ogunsola, Titilola [1 ,2 ]
Chen, Dinah [1 ]
Elgin, Ceyhun [1 ,4 ]
Patel, Vipul [1 ]
Wronka, Andrew [1 ]
Al-Aswad, Lama A. [1 ,3 ,5 ]
机构
[1] NYU, Grossman Sch Med, Dept Ophthalmol, New York, NY USA
[2] New York Med Coll, New York, NY USA
[3] NYU, Grossman Sch Med, Dept Populat Hlth, New York, NY USA
[4] Bogazici Univ, Istanbul, Turkey
[5] NYU Langone Hlth, Dept Ophthalmol, 222 East 41st St,4th Floor, New York, NY 10017 USA
来源
OPHTHALMOLOGY SCIENCE | 2022年 / 2卷 / 03期
关键词
Ophthalmology; Smartphone-based visual acuity test; Telemedicine; Tele-ophthalmology; Visual acuity; ETDRS LOGMAR; CHART; REPEATABILITY; RELIABILITY;
D O I
10.1016/j.xops.2022.100182
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To validate and assess user satisfaction and usability of the New York University (NYU) Langone Eye Test application, a smartphone-based visual acuity (VA) test. Design: Mixed-methods cross-sectional cohort study. Participants: Two hundred forty-four eyes of 125 participants were included. All participants were adults 18 years of age or older. Participants' eyes with a VA of 20/400 (1.3 logarithm of the minimum angle of resolution [logMAR]) or worse were excluded. Methods: Patients were tested using the clinical standard Rosenbaum near card and the NYU Langone Eye Test application on an iPhone and Android device. Each test was performed twice to measure reliability. Ten patients were selected randomly for subsequent semistructured qualitative interviews with thematic analysis. Main Outcome Measures: Visual acuity was the parameter measured. Bland-Altman analysis was used to measure agreement between the results of the NYU Langone Eye Test application and Rosenbaum card, as well as test-retest reliability of each VA. The correlation between results was calculated using the intraclass corre-lation coefficient. Satisfaction survey and semistructured interview questions were developed to measure usability and acceptability. Results: Bland-Altman analysis revealed an agreement between the application and the Rosenbaum near card of 0.017 & PLUSMN; 0.28 logMAR (iPhone) and 0.009 & PLUSMN; 0.29 logMAR (Android). The correlation between the appli-cation and the Rosenbaum near card was 0.74 for both the iPhone and Android. Test-retest reliability was 0.003 & PLUSMN; 0.22 logMAR (iPhone), 0.01 & PLUSMN; 0.25 logMAR (Android), and 0.01 & PLUSMN; 0.23 logMAR (Rosenbaum card). Of the 125 participants, 97.6% found the application easy to use, and 94.3% were overall satisfied with the application. Thematic analysis yielded 6 key themes: (1) weaknesses of application, (2) benefits of the application, (3) tips for application improvement, (4) difficulties faced while using the application, (5) ideal patient for application, and (6) comparing application with traditional VA testing. Conclusions: The NYU Langone Eye Test application is a user-friendly, accurate, and reliable measure of near VA. The application's integration with the electronic health record, accessibility, and easy interpretation of results, among other features, make it ideal for telemedicine use. Ophthalmology Science 2022;2:100182 & COPY; 2022 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:8
相关论文
共 50 条
  • [32] Development of a smartphone-based Turkish digits in noise test
    Cetinkaya, Umit Can
    Konukseven, Ozlem
    [J]. EGYPTIAN JOURNAL OF OTOLARYNGOLOGY, 2023, 39 (01):
  • [33] Optokinetic test to evaluate visual acuity of each eye independently
    Thomas, BB
    Seiler, MJ
    Sadda, SR
    Coffey, PJ
    Aramant, RB
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2004, 138 (1-2) : 7 - 13
  • [34] Subjective Visual Vertical Evaluation by a Smartphone-based Test-Taking the Phone Out of the Bucket
    Wengier, Anat
    Ungar, Omer J.
    Handzel, Ophir
    Cavel, Oren
    Oron, Yahav
    [J]. OTOLOGY & NEUROTOLOGY, 2021, 42 (03) : 455 - 460
  • [35] Development and validation of a smartphone-based digits-in-noise hearing test in South African English
    Potgieter, Jenni-Mari
    Swanepoel, De Wet
    Myburgh, Hermanus Carel
    Hopper, Thomas Christopher
    Smits, Cas
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2016, 55 (07) : 405 - 411
  • [36] Smartphone-based audiometric test for screening hearing loss in the elderly
    Sara Abu-Ghanem
    Ophir Handzel
    Lior Ness
    Miri Ben-Artzi-Blima
    Karin Fait-Ghelbendorf
    Mordechai Himmelfarb
    [J]. European Archives of Oto-Rhino-Laryngology, 2016, 273 : 333 - 339
  • [37] Smartphone-based audiometric test for screening hearing loss in the elderly
    Abu-Ghanem, Sara
    Handzel, Ophir
    Ness, Lior
    Ben-Artzi-Blima, Miri
    Fait-Ghelbendorf, Karin
    Himmelfarb, Mordechai
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (02) : 333 - 339
  • [38] Validation of the Waterloo Differential Visual Acuity Test (WatDAT) and Comparison With Existing Pediatric Tests of Visual Acuity
    Opoku-Yamoah, Victor
    Christian, Lisa W.
    Irving, Elizabeth L.
    Jones, Deborah
    McCulloch, Daphne
    Rose, Kalpana
    Leat, Susan J.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (09):
  • [39] Performance evaluation of a smartphone-based home test for fecal calprotection
    Michaelis, Simon
    Hochfellner, Anna
    Schneider, Christopher
    Schnedl, Wolfgang J.
    Baranyi, Andreas
    Enko, Dietmar
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024,
  • [40] Validating a Smartphone-Based Pedestrian Navigation System Prototype An Informal Eye-Tracking Pilot Test
    Kluge, Mario
    Asche, Hartmut
    [J]. COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2012, PT II, 2012, 7334 : 386 - 396