The use of hand-carried ultrasound in the hospital setting - A cost-effective analysis

被引:45
|
作者
Greaves, K [1 ]
Jeetley, P [1 ]
Hickman, M [1 ]
Dwivedi, G [1 ]
Sabharwal, N [1 ]
Lim, T [1 ]
Janardhanan, R [1 ]
Senior, R [1 ]
机构
[1] Northwick Pk Hosp & Clin Res Ctr, Dept Cardiovasc Med, Harrow HA1 3UJ, Middx, England
关键词
D O I
10.1016/j.echo.2004.09.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We sought to assess the accuracy of hand-carried ultrasound (HCU) in the prediction of a normal study, and its cost-effectiveness in reducing the number of standard departmental echocardiograms; (SDE) performed on hospital inpatients. Methods: The setting was a district general hospital. Participants were 157 consecutive inpatients, mean age 68 (range: 18-97) years, 95 men (61%), referred for SDE. HCU was performed at the bedside as part of the clinical assessment. SDE was performed routinely. Main outcome measures were: (1) assessment of the accuracy of HCU in detection of a normal or abnormal study as determined by SDE; and (2) a cost-effectiveness analysis. Results. Indications for echocardiography were: left ventricular (LV) function assessment, n = 101 (64.3%); valvular abnormalities, n = 11 (7%); arrhythmia, n = 4 (2.6%); miscellaneous, n = 10 (6.4%); and no reason stated, 31 (19.7%). The sensitivity, specificity, and positive and negative predictive values of HCU predicting a completely normal scan were 74%, 96%, 94%, and 81%, respectively, and of predicting normal LV function in requests specific for LV function assessment were 81%, 100%, 100%, and 77%, respectively. If either all inpatients or those with requests for LV function assessment underwent HCU initially, and only those with abnormal scans underwent further SDE, there would be a 29% and 22% reduction in departmental workload and a cost saving of 23,000 pounds and 30,000 pounds, respectively. Conclusion: HCU is an accurate method of identifying patients with normal hearts as determined by SDE. Its routine use is cost-effective and can significantly reduce the number of SDE that need be performed.
引用
收藏
页码:620 / 625
页数:6
相关论文
共 50 条
  • [41] Triage patients with suspected pulmonary embolism in emergency department using hand-carried ultrasound device
    Mansencal, N
    Vieillard-Baron, A
    Faroot, JC
    Morelon, S
    El Hajjam, M
    Dufaitre, G
    Brun-Ney, D
    Lacombe, P
    Dubourg, O
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 371A - 371A
  • [42] Left Ventricular Geometric Abnormality Screening in Hypertensive Patients Using a Hand-Carried Ultrasound Device
    Perez-Avraham, Galit
    Kobal, Sergio L.
    Etzion, Ohad
    Novack, Victor
    Wolak, Talya
    Liel-Cohen, Noah
    Paran, Esther
    JOURNAL OF CLINICAL HYPERTENSION, 2010, 12 (03): : 181 - 186
  • [43] Reliability of cardiac dimensions and valvular regurgitation assessment by sonographers using hand-carried ultrasound devices
    Coletta, Claudio
    De Marchis, Elettra
    Lenoli, Monica
    Rosato, Stefano
    Renzi, Marco
    Sestili, Augusto
    Romano, Patrizia
    Infusino, Tommaso
    Ricci, Roberto
    Ceci, Vincenzo
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (04): : 275 - 283
  • [44] Detection of left atrial enlargement using hand-carried ultrasound devices to screen for cardiac abnormalities
    Kimura, BJ
    Fowler, SJ
    Fergus, TS
    Minuto, JJ
    Amundson, SA
    Gilpin, EA
    DeMaria, AN
    AMERICAN JOURNAL OF MEDICINE, 2005, 118 (08): : 912 - 916
  • [45] Value of hand-carried ultrasound device in triage patients with suspected pulmonary embolism in emergency department
    Mansencal, N.
    Vieillard-Baron, A.
    Farcot, J. C.
    El Hajjam, M.
    Dufaitre, G.
    Brun-Ney, D.
    Lacombe, P.
    Dubourg, O.
    EUROPEAN HEART JOURNAL, 2005, 26 : 303 - 304
  • [46] A hand-carried cardiac ultrasound device in the outpatient cardiology clinic reduces the need for standard echocardiography
    Trambaiolo, P.
    Papetti, F.
    Posteraro, A.
    Amici, E.
    Piccoli, M.
    Cerquetani, E.
    Pastena, G.
    Gambelli, G.
    Salustri, A.
    HEART, 2007, 93 (04) : 470 - 475
  • [47] Hospitalists' Ability to Use Hand-Carried Ultrasound for Central Venous Pressure Estimation After a Brief Training Intervention: A Pilot Study
    Martin, L. David
    Ziegelstein, Roy C.
    Howell, Eric E.
    Martire, Carol
    Hellmann, David B.
    Hirsch, Glenn A.
    JOURNAL OF HOSPITAL MEDICINE, 2013, 8 (12) : 711 - 714
  • [48] SHALY GAS-SAND ANALYSIS USING HAND-CARRIED CALCULATORS.
    Wu, Ching H.
    Krug, Jack
    Log Analyst, 1979, 20 (03): : 20 - 25
  • [49] HEPATITIS-B IMMUNOPROPHYLAXIS - DEVELOPING A COST-EFFECTIVE PROGRAM IN THE HOSPITAL SETTING
    LANPHEAR, BP
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1990, 11 (01): : 47 - 50
  • [50] Efficacy of ultrasound-assisted stress testing using a hand-carried ultrasound device for diagnosis of coronary artery disease
    Hirano, Yutaka
    Uehara, Hisakazu
    Nakamura, Hajime
    Ikuta, Shin-ichirou
    Nakano, Manabu
    Akiyama, Seita
    Ishikawa, Kinji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (05) : 536 - 539