Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement

被引:42
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [2 ]
Yeh, Victoria [2 ]
Chiou, Allen J. [2 ]
Gorrepati, Madhu L.
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Dept Surg, Clark Ctr E350A, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
ENDOVASCULAR ANEURYSM REPAIR; STENT-GRAFT MIGRATION; BLOOD-FLOW; TRIAL;
D O I
10.1016/j.jvs.2010.01.058
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective:Endograft migration is usually described as a downward displacement of the endograft with respect to the renal arteries. However, change in endograft position is actually a complex process in three-dimensional (3D) space. Currently, there are no established techniques to define such positional changes over time. The purpose of this study is to determine whether the direction of aortic endograft movement as observed in follow-up computed tomography (CT) scans is related to the directional displacement force acting on the endograft. Methods: We quantitated the 3D positional change over time of five abdominal endografts by determining the endograft centroid at baseline (postoperative scan) and on follow-up CT scans. The time interval between CT scans for the 5 patients ranged from 8 months to 8 years. We then used 3D image segmentation and computational fluid dynamics (CFD) techniques to quantitate the pulsatile displacement force (in Newtons [NI]) acting on the endografts in the postoperative configurations. Finally, we calculated a correlation metric between the direction of the displacement force vector and the endograft movement by computing the cosine of the angle of these two vectors. Results: The average 3D movement of the endograft centroid was 18 mm (range, 9-29 mm) with greater movement in patients with longer follow-up times. In all cases, the movement of the endograft had significant components in all three spatial directions: Two of the endografts had the largest component of movement in the transverse direction, whereas three endografts had the largest component of movement in the axial direction. The magnitude and orientation of the endograft displacement force varied depending on aortic angulation and hemodynamic conditions. The average magnitude of displacement force for all endografts was 5.8 N (range, 3.7-9.5 N). The orientation of displacement force was in general perpendicular to the greatest curvature of the endograft. The average correlation metric, defined as the cosine of the angle between the displacement force and the endograft centroid movement, was 0.38 (range, 0.08-0.66). Conclusions: Computational methods applied to patient-specific postoperative image data can be used to quantitate 3D displacement force and movement of endografts over time. It appears that endograft movement is related to the magnitude and direction of the displacement force acting on aortic endografts. These methods can be used to increase our understanding of clinical endograft migration. (J Vase Surg 2010;51:1488-97.)
引用
收藏
页码:1488 / 1497
页数:10
相关论文
共 50 条
  • [1] In Vivo Displacement Force (DF) Is Higher in Patients Who Experience Aortic Endograft Migration: A 3D Computational Analysis
    Figueroa, Carlos A.
    Yeh, Victoria
    Taylor, Charles A.
    Gorrepati, Madhu L.
    Zarins, Christopher K.
    JOURNAL OF VASCULAR SURGERY, 2010, 51 : 93S - 93S
  • [2] Preliminary 3D computational fluids dynamics analysis of the Wells turbine
    Thakker, A
    Frawley, P
    Daly, J
    Bajeet, ES
    PROCEEDINGS OF THE 10TH (2000) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL I, 2000, : 442 - 451
  • [3] BRIDGING THE GAP BETWEEN COMPUTATIONAL AND EXPERIMENTAL 3D CELL FORCE CALCULATION
    Barrasa-Fano, Jorge
    Shapeti, Apeksha
    Zivic, Andreja
    Geroski, Tijana
    Filipovic, Nenad
    Sanz-Herrera, Jose Antonio
    Van Oosterwyck, Hans
    JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2024, 18 (01) : 124 - 129
  • [4] The 3D Measurement of Speed and Direction of Turbulent Air Movement
    Shirokov, I. B.
    Shabalina, O. V.
    Palgov, F. E.
    2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 3470 - 3473
  • [5] Relationship between forehead motion and the shape of forehead lines-A 3D skin displacement vector analysis
    Frank, Konstantin
    Freytag, David L.
    Schenck, Thilo L.
    Green, Jeremy B.
    Trovato, Alexa
    Barade, Hassan
    Rosamilia, Gianna
    Lachman, Nirusha
    Giunta, Riccardo E.
    Cotofana, Sebastian
    JOURNAL OF COSMETIC DERMATOLOGY, 2019, 18 (05) : 1224 - 1229
  • [6] 3D force and displacement sensor for SFA and AFM measurements
    Kristiansen, Kai
    McGuiggan, Patricia
    Carver, Greg
    Meinhart, Carl
    Israelachvili, Jacob
    LANGMUIR, 2008, 24 (04) : 1541 - 1549
  • [7] Preliminary study of seismic permanent displacement of 3D slope
    Lu, Kun-Lin
    Zhu, Da-Yong
    Zhu, Ya-Lin
    Xu, Qiang
    Yantu Lixue/Rock and Soil Mechanics, 2011, 32 (05): : 1425 - 1429
  • [8] Preliminary study of seismic permanent displacement of 3D slope
    Lu Kun-lin
    Zhu Da-yong
    Zhu Ya-lin
    Xu Qiang
    ROCK AND SOIL MECHANICS, 2011, 32 (05) : 1425 - 1429
  • [9] 3D Analysis of Tooth Movement Using 3D Technology
    Kau, Chung How
    Wilma, David A. Cruz
    CURRENT OSTEOPOROSIS REPORTS, 2020, 22 (6) : 536 - 543
  • [10] 3D digital analysis of magnetic force-driven orthodontic tooth movement
    Kuwajima, Yukinori
    Ishida, Yoshiki
    Lee, Cliff
    Mayama, Hisayo
    Satoh, Kazuro
    Ishikawa-Nagai, Shigemi
    HELIYON, 2019, 5 (11)