Accuracy of Flowmeters Measuring Horizontal Groundwater Flow in an Unconsolidated Aquifer Simulator

被引:20
|
作者
Bayless, E. R. [1 ]
Mandell, Wayne A. [2 ]
Ursic, James R. [3 ]
机构
[1] US Geol Survey, Indiana Water Sci Ctr, Indianapolis, IN 46278 USA
[2] USA, Ctr Environm, Aberdeen Proving Ground, MD USA
[3] US EPA, Chicago, IL USA
来源
关键词
BOREHOLE FLOWMETER; WATER FLOW;
D O I
10.1111/j.1745-6592.2010.01324.x
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Borehole flowmeters that measure horizontal flow velocity and direction of groundwater flow are being increasingly applied to a wide variety of environmental problems. This study was carried out to evaluate the measurement accuracy of several types of flowmeters in an unconsolidated aquifer simulator. Flowmeter response to hydraulic gradient, aquifer properties, and well-screen construction was measured during 2003 and 2005 at the U.S. Geological Survey Hydrologic Instrumentation Facility in Bay St. Louis, Mississippi. The flowmeters tested included a commercially available heat-pulse flowmeter, an acoustic Doppler flowmeter, a scanning colloidal borescope flowmeter, and a fluid-conductivity logging system. Results of the study indicated that at least one flowmeter was capable of measuring borehole flow velocity and direction in most simulated conditions. The mean error in direction measurements ranged from 15.1 degrees to 23.5 degrees and the directional accuracy of all tested flowmeters improved with increasing hydraulic gradient. The range of Darcy velocities examined in this study ranged 4.3 to 155 ft/d. For many plots comparing the simulated and measured Darcy velocity, the squared correlation coefficient (r2) exceeded 0.92. The accuracy of velocity measurements varied with well construction and velocity magnitude. The use of horizontal flowmeters in environmental studies appears promising but applications may require more than one type of flowmeter to span the range of conditions encountered in the field. Interpreting flowmeter data from field settings may be complicated by geologic heterogeneity, preferential flow, vertical flow, constricted screen openings, and nonoptimal screen orientation.
引用
收藏
页码:48 / 62
页数:15
相关论文
共 50 条
  • [41] ACCURACY OF BLOOD-FLOW MEASUREMENTS BY MEANS OF MULTICHANNEL ULTRASOUND FLOWMETERS
    ANLIKER, M
    DORIOT, PA
    BOLLINGE.A
    BRUNNER, HH
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 334 - 334
  • [42] GROUNDWATER-FLOW THROUGH A MILIOLITE LIMESTONE AQUIFER
    RUSHTON, KR
    RAO, SVR
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1988, 33 (05): : 449 - 464
  • [43] The aquifer of the Mamora Basin, Morocco: geometry and groundwater flow
    Zouhri, L
    JOURNAL OF AFRICAN EARTH SCIENCES, 2002, 32 (04): : 837 - 850
  • [44] Invariant system for measuring the flow rate of wet gas on Coriolis flowmeters
    Dayev, Zh A.
    Yuluyev, V. T.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 70
  • [45] Posiva groundwater flow measuring techniques
    Rouhiainen, P
    NEW APPROACHES CHARACTERIZING GROUNDWATER FLOW, VOLS 1 AND 2, 2001, : 785 - 789
  • [46] Mathematical models of groundwater flow with a horizontal drain
    Emikh, V. N.
    WATER RESOURCES, 2008, 35 (02) : 205 - 211
  • [47] Mathematical models of groundwater flow with a horizontal drain
    V. N. Emikh
    Water Resources, 2008, 35 : 205 - 211
  • [48] Estimates of Horizontal Groundwater Flow Velocities in Boreholes
    Bayer-Raich, Marti
    Credoz, Anthony
    Guimera, Jordi
    Jordana, Salvador
    Sampietro, Diego
    Font-Capo, Jordi
    Nief, Nathalie
    Grossemy, Matthieu
    GROUNDWATER, 2019, 57 (04) : 525 - 533
  • [49] PARAMETER ESTIMATION OF UNCONFINED AQUIFER BY MEASURING CHANGE OF GROUNDWATER LEVEL.
    Arai, Katsuhiko
    Ohnishi, Yuzo
    Kasagawa, Masaaki
    Soils and Foundations, 1985, 25 (04) : 129 - 134
  • [50] Generalized Analytical Solutions for Groundwater Head in a Horizontal Aquifer in the Presence of Subsurface Drains
    Singh, Sushil K.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2009, 135 (03) : 295 - 302