Power-Based Concept for Current Injection by Inverter-Interfaced Distributed Generations during Transmission-Network Faults

被引:1
|
作者
Polajzer, Bostjan [1 ]
Grcar, Bojan [1 ]
Cernelic, Jernej [2 ]
Ritonja, Jozef [1 ]
机构
[1] Univ Maribor, Fac Elect Engn & Comp Sci, SI-2000 Maribor, Slovenia
[2] MAHLE Elect Drives Slovenija Doo, SI-5290 Sempeter Pri Gorici, Slovenia
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 21期
关键词
distributed generation; fault current injection; voltage support; distance protection; VOLTAGE SUPPORT CONTROL; CONTROL STRATEGY; PROTECTION COORDINATION; DISTRIBUTION-SYSTEMS; OVERCURRENT RELAYS; CURRENT LIMITATION; SHORT-CIRCUIT; PV INVERTERS; RIDE;
D O I
10.3390/app112110437
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper analyzes the influence of inverter-interfaced distributed generations' (IIDGs) response during transmission network faults. The simplest and safest solution is to switch IIDGs off during network faults without impacting the network voltages. A more elaborate and efficient concept, required by national grid codes, is based on controlling the IIDGs' currents, involving positive- and negative-sequence voltage measured at the connection point. In this way the magnitude and phase of the injected currents can be adjusted, although the generated power will depend on the actual line voltages at the connection point. Therefore, an improved concept is proposed to adjust IIDGs' fault current injection through the required active and reactive power, employing the same voltage characteristics. The proposed, i.e., power-based concept, is more definite than the current-based one, since the required power will always be generated. The discussed concepts for the fault current injection by IIDGs were tested in different 110-kV networks with loop and radial topologies, and for different short-circuit capabilities of the aggregated network supply. Based on extensive numerical calculations, the power-based concept during transmission networks faults generates more reactive power compared to the current-based concept. However, the voltage support by IIDGs during transmission networks faults, regardless of the concept being used, is influenced mainly by the short-circuit capability of the aggregated network supply. As regards distance protection operation, it is influenced additionally by the network topology, i.e., in radial network topology, the remote relay's operation can be delayed due to a largely seen impedance.
引用
收藏
页数:15
相关论文
共 25 条
  • [1] Steady-State Response of Inverter-Interfaced Distributed Generations During Transmission Network Faults
    Polajzer, Bostjan
    Pintaric, Matej
    Topler, Marcel
    Grcar, Bojan
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [2] An Improved Pilot Protection for Distribution Network With Inverter-Interfaced Distributed Generations
    Han, Bowen
    Wang, Gang
    Li, Haifeng
    Zeng, Dehui
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 2555 - 2559
  • [3] Current Differential Protection for Distribution Network with Inverter-interfaced Distributed Generators Based on Injection of Harmonic Signal
    Li H.
    Zhang Z.
    Liang Y.
    Liang H.
    Wang G.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (22): : 120 - 128
  • [4] Optimized Fault Location Identification in Power Distribution Systems With Inverter-Interfaced Distributed Generations
    Kahnamouei, Ali Shakeri
    Lotfifard, Saeed
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3429 - 3440
  • [5] Fault Location in Distribution Network with Inverter-Interfaced Distributed Energy Resources in Limiting Current
    Orozco-Henao, C.
    Bretas, A. S.
    Leborgne, R. C.
    Herrera, A.
    Martinez, S.
    PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, : 231 - 236
  • [6] Loop Analysis Method for Short Circuit Current Calculation of Distribution Network with Inverter-Interfaced Distributed Generators
    Wang, Shouxiang
    Jiang, Xingyue
    Li, Qionghui
    Huang, Bibin
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2909 - 2914
  • [7] A Novel Real-time Estimation Method for Fault Current of Inverter-Interfaced Distributed Generations T Connecting in Feeder
    Han Bowen
    Wang Gang
    Li Haifeng
    Cai Yingqian
    Zhong Qing
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [8] A protection scheme for active distribution network based on the cooperative control of inverter-interfaced distributed generators
    Guo Wenming
    Wang Hongru
    ENERGY REPORTS, 2022, 8 : 342 - 352
  • [9] Adaptive Distance Protection Based on the Analytical Model of Additional Impedance for Inverter-Interfaced Renewable Power Plants During Asymmetrical Faults
    Chao, Chenxu
    Zheng, Xiaodong
    Weng, Yang
    Liu, Yu
    Gao, Piao
    Tai, Nengling
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3823 - 3834
  • [10] A protection scheme for active distribution network based on the cooperative control of inverter-interfaced distributed generators
    Guo, Wenming
    Wang, Hongru
    Energy Reports, 2022, 8 : 342 - 352