A study on the abutment screw loosening phenomenon of dental implant

被引:0
|
作者
Kang, YM [1 ]
Cho, IH [1 ]
机构
[1] DANKOOK UNIV,SCH DENT,DEPT PROSTHODONT,SEOUL,SOUTH KOREA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
引用
收藏
页码:1261 / 1261
页数:1
相关论文
共 50 条
  • [31] Preventing loosening of implant abutment screws
    Cavazos, E
    Bell, FA
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05): : 566 - 569
  • [32] Influence of the coating material on the loosing of dental implant abutment screw joints
    Elias, C. N.
    Figueira, D. C.
    Rios, P. R.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (08): : 1361 - 1366
  • [33] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [34] Abutment screw loosening in implants: A literature review
    Alsubaiy, Ebrahim F.
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (11) : 5490 - 5494
  • [35] Abutment screw loosening in angulation-correcting implants: An in vitro study
    Hotinski, Elena
    Dudley, James
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 151 - 155
  • [36] Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System
    Sim, Bo Kyun
    Kim, Bongju
    Kim, Min Jeong
    Jeong, Guk Hyun
    Ju, Kyung Won
    Shin, Yoo Jin
    Kim, Man Yong
    Lee, Jong-Ho
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [37] Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
    Rico-Coderch, Aitana
    Felix, Luis F.
    Sola-Ruiz, Maria Fernanda
    Medina, Michell
    Agustin-Panadero, Ruben
    Ortega, Rocio
    Cascos, Rocio
    Gomez-Polo, Miguel
    METALS, 2024, 14 (07)
  • [38] Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis
    Kim, Seok-Gyu
    Chung, Chae-Heon
    Son, Mee-Kyoung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (03): : 207 - 213
  • [39] Mechanical joint of abutment/fixture screw interface in the internal dental implant system
    Chung, Chae Heon
    Choe, Han Cheol
    Kim, Hee Jung
    Kim, Jin Sup
    Brantley, William
    MECHANICAL BEHAVIOR OF MATERIALS X, PTS 1AND 2, 2007, 345-346 : 1417 - +
  • [40] Procedure for obturating the access canal and preventing the loosening of the abutment screw in an implant-retained fixed prosthesis
    von Krammer, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (02): : 234 - 236