Anterior Surface-Based Keratometry Compared With Scheimpflug Tomography-Based Total Corneal Astigmatism

被引:86
|
作者
Tonn, Bastian [1 ]
Klaproth, Oliver Klaus [1 ]
Kohnen, Thomas [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Ophthalmol, D-60590 Frankfurt, Germany
关键词
astigmatism; corneal topography; posterior astigmatism; Pentacam; Scheimpflug photography; POSTERIOR; TORICITY; PENTACAM; CAMERA; RADIUS;
D O I
10.1167/iovs.14-15659
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Description of total corneal refractive power (TCRP) astigmatism by ray tracing using a Scheimpflug tomographer. METHODS. Analysis of Scheimpflug tomography measurements to determine 3-mm-zone TCRP astigmatism (CA(TCRP)) by ray tracing calculations, astigmatism in 15 degrees-zone from simulated keratometry (CA(Sim-K)), anterior-surface astigmatism (CA(ant)), and posterior-surface astigmatism (CA(post)). An analysis of changes with age was performed. The error produced by estimating CA(TCRP) using CA(Sim-K) was calculated through vector analyses. The percentages of steep meridian aligned vertically, obliquely, and horizontally of CA(ant) and CA(post) were calculated. RESULTS. A total of 3818 healthy, previously unoperated eyes were analyzed. The mean magnitude of CA(post) was -0.33 diopter (D). A vertically aligned steep meridian (60 degrees to 120 degrees) was found in 71.2% of eyes for CA(ant) and in 88.8% for CA(post). With increasing age, the occurrence of steep meridian aligned horizontally in CA(ant) increased from 9.1% (age 20-29 years) to 31.8% (70-79 years), while vertical alignment decreased from 77.4% to 48.1%. Alignment of CA(post) mostly remained vertical (90.9%-80.7%). When CA(ant) is vertical, CA(post) is vertical in 97% and CA(Sim-K) overestimates total corneal astigmatism (mean 0.11 +/- 0.22 D). When CA(ant) is horizontal, 18% of CA(post) is horizontal and CA(Sim-K) underestimates (mean 0.26 +/- 0.31 D) total corneal astigmatism. The mean vector difference between CA(TCRP) and CA(Sim-K) was 0.18 at 178 degrees and exceeded 0.50 D in 9% of eyes. CONCLUSIONS. Total corneal astigmatism is overestimated by CA(Sim-K) in eyes with with-the-rule astigmatism and cannot be predicted safely in eyes that do not have with-the-rule astigmatism by anterior measurements only.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [1] Posterior and total corneal astigmatism measured with optical coherence tomography-based biometer and dual Scheimpflug analyzer
    Wang, Li
    Cao, Danmin
    Vilar, Cesar
    Koch, Douglas D.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : 1652 - 1658
  • [2] Corneal Astigmatism Measurement by Ray Tracing Versus Anterior Surface-Based Keratometry in Candidates for Toric lntraocular Lens Implantation
    De Sanctis, Ugo
    Donna, Piero
    Penna, Rachele R.
    Calastri, Maria Isabella
    Eandi, Chiara M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 177 : 1 - 8
  • [3] Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging
    Giacomo Savini
    Leonardo Taroni
    Domenico Schiano-Lomoriello
    Kenneth J. Hoffer
    [J]. Eye, 2021, 35 : 307 - 315
  • [4] Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging
    Savini, Giacomo
    Taroni, Leonardo
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    [J]. EYE, 2021, 35 (01) : 307 - 315
  • [5] Accuracy of total corneal topographic astigmatism (CORT total) compared to total keratometry (TK)
    Alpins, Noel
    Ong, James
    Stamatelatos, George
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 45 - 45
  • [6] Peripheral corneal relaxing incisions based on anterior keratometry from Scheimpflug tomography versus Placido topography during standard cataract surgery
    Nanavaty, Mayank A.
    Dizon, Marizol
    Malde, Shruti
    Favor, Danillo
    Lake, Damian B.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (02) : 297 - 305
  • [7] Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism
    Muzyka-Wozniak, Maria
    Oleszko, Adam
    Grzybowski, Andrzej
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [8] Peripheral corneal relaxing incisions based on anterior keratometry from Scheimpflug tomography versus Placido topography during standard cataract surgery
    Mayank A. Nanavaty
    Marizol Dizon
    Shruti Malde
    Danillo Favor
    Damian B. Lake
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 297 - 305
  • [9] Monitoring the transition from corneal ulceration to healed scar using a Scheimpflug tomography-based densitometry
    Chen, Yen-Cheng
    Hsiao, Yu-Ting
    Kuo, Shu-Fang
    Yu, Hun-Ju
    Fang, Po-Chiung
    Ho, Ren-Wen
    Yang, I-Hui
    Kuo, Ming-Tse
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (07) : 2189 - 2198
  • [10] A mathematical model for corneal posterior astigmatism calculus based on corneal anterior astigmatism
    Pacheco Del Valle, Cristina
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)