Beat-to-beat Intervals of Speckle & Intensity-based Optical Plethysmograms compared to Electrocardiogram

被引:6
|
作者
Olazabal, Jorge Herranz [1 ,2 ]
Wieringa, Fokko [3 ,4 ]
Hermeling, Evelien [3 ]
Van Hoof, Christopher [1 ,2 ]
机构
[1] IMEC, Leuven, Belgium
[2] Katholieke Univ Leuven, Leuven, Belgium
[3] Imec NL, Eindhoven, Netherlands
[4] Univ Med Ctr Utrecht, Utrecht, Netherlands
关键词
SPECKLEPLETHYSMOGRAPHIC SPG;
D O I
10.23919/CinC53138.2021.9662819
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study evaluates video sequences obtained by a form of laser speckle imaging (LSI) - referred to as remote camera-derived Speckleplethysmography (rSPG) - in comparison to common clinical parameters (PPG & ECG). For 9 human subjects we illuminated the index finger with a laser (639 nm, 10 mW, spot diameter 5.6 mm), captured video streams with a camera (Basler acA2000-340km, 25 cm distance, 100 fps) and evaluated spatial variations in the captured speckle patterns. We simultaneously collected contact-mode transmissive photoplethysmography (PPG) and electrocardiography (ECG) signals. We derived beat-to-beat (b-2-b) intervals from both rSPG and contact-mode PPG signals and compared both with the ECG R-R intervals `goldstandard' (3234 heart-cycles in total). B-2-b interval error distributions of rSPG vs contact PPG showed: mean absolute deviation 10.4 vs 14.2 ms; standard deviation 25.2 vs 30.1 ms. Two-sample F-test revealed significantly different variances (p < 0.001, 99% confidence). Additional Levene's test: F (1, 6468) = 37.602, p = 0. This study demonstrates that contactless cameraderived rSPG can obtain b-2-b intervals at least as good as routine clinical contact-mode transmissive finger clip PPG. This might enable innovative applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] BEAT-TO-BEAT INTERVAL MEASUREMENT IN THE ELECTROCARDIOGRAM
    KOELEMAN, ASM
    ROS, HH
    VANDENAKKER, TJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 213 - 219
  • [2] The processing of beat-to-beat time intervals by multipoles
    Lewkowicz, M
    Levitan, J
    Saermark, K
    Thomsen, PEB
    MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2003 (INCLUDING BIOLOGICAL SYSTEMS), 2003, : 199 - 202
  • [3] Filtering beat-to-beat recordings of the high resolution electrocardiogram
    Kestler, HA
    Hoher, M
    Schwenker, F
    Hombach, V
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 461 - 464
  • [4] Support system for classification of beat-to-beat arrhythmia based on variability and morphology of electrocardiogram
    Queiroz, Jonathan Araujo
    Anaisse Azoubel, Luana Monteiro
    Barros, Allan Kardec
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2019, 2019 (1)
  • [5] Support system for classification of beat-to-beat arrhythmia based on variability and morphology of electrocardiogram
    Jonathan Araujo Queiroz
    Luana Monteiro Anaisse Azoubel
    Allan Kardec Barros
    EURASIP Journal on Advances in Signal Processing, 2019
  • [6] Heart Beat-to-Beat Intervals Classification for Epileptic Seizure Prediction
    Popov, Anton
    Panichev, Oleg
    Karplyuk, Yevgeniy
    Smirnov, Yaroslav
    Zaunseder, Sebastian
    Kharytonov, Volodymyr
    2017 SIGNAL PROCESSING SYMPOSIUM (SPSYMPO), 2017,
  • [7] BEAT-TO-BEAT HIGH-RESOLUTION ELECTROCARDIOGRAM - TECHNICAL AND CLINICAL ASPECTS
    ELSHERIF, N
    MEHRA, R
    RESTIVO, M
    PROGRESS IN CARDIOVASCULAR DISEASES, 1993, 35 (06) : 407 - 415
  • [8] Beat-to-beat noise removal in noninvasive his-bundle electrocardiogram
    Bazhyna, A
    Gotchev, A
    Christov, II
    Daskalov, IK
    Egiazarian, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (05) : 712 - 719
  • [9] Beat-to-beat noise removal in noninvasive His-bundle electrocardiogram
    A. Bazhyna
    A. Gotchev
    I. I. Christov
    I. K. Daskalov
    K. Egiazarian
    Medical and Biological Engineering and Computing, 2004, 42 : 712 - 719
  • [10] Beat-to-beat Variability of QT Intervals Just Before Ventricular Fibrillation Documented by 24-hour Holter Electrocardiogram
    Okuda, Kentarou
    Watanabe, Eiichi
    Yamamoto, Mayumi
    Sano, Kan
    Sobue, Yoshihiro
    Uchiyama, Tatsushi
    Ozaki, Yukiko
    CIRCULATION, 2009, 120 (18) : S681 - S681