Three-dimensional automatic image warping in cardiac SPECT

被引:1
|
作者
Ella, A [1 ]
Champier, J [1 ]
Bontemps, L [1 ]
Itti, R [1 ]
机构
[1] Fac Med RTH LAENNEC, Biophys Lab, F-69008 Lyon, France
关键词
D O I
10.1097/00006231-200012000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study presents a new tool for the visualization and analysis of three-dimensional (3-D) cardiac single-photon Emission computed tomography (SPECT). The first step consisted of computing the 3-D pseudo-skeleton of a binarized myocardium and, using the skeleton points, to design a bullet model (half ellipsoid prolonged by a cylinder). Afterwards, this model was used to drive the warping of the 3-D myocardium, initially egg-shaped, into a thick, flat disc using the thin-plate splines as deformation method. Hence, instead of achieving several rotations of the initial egg-shaped volume to have an idea on the myocardial outer face (Epicardial) only, the whole myocardium is seen by looking either on toy of the disc-shaped transformed myocardium (epicardial surface) or underneath for the inner face (endocardial). This new share permitted us to localize any type of defect and to evaluate its extent and depth just by a single glance. A detailed analysis, achieved after stripping away this shape in about 10 layers, allowed us to evaluate the defect extent layer by layer and to determine whether the defect involves the totality of the myocardium layers. Finally its flattening following the ventricular long-axis led to a summed bull's eye, ((C) 2000 Lippincott Williams & Wilkins).
引用
收藏
页码:1135 / 1146
页数:12
相关论文
共 50 条
  • [31] Three-dimensional total variation norm for SPECT reconstruction
    Persson, M
    Bone, D
    Elmqvist, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 98 - 102
  • [32] Three-dimensional composite images of SPECT/MRI in hydrocephalus
    Mito, T
    Shibata, I
    Sugo, N
    Takano, M
    [J]. CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1022 - 1022
  • [33] Three-dimensional registration and analysis for brain SPECT images
    Liao, YL
    Sun, YN
    Chiu, NT
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2715 - 2719
  • [34] A Three-Dimensional Piezoelectric Timoshenko Beam Model Including Torsion Warping
    Beltramo, Emmanuel
    Roccia, Bruno A.
    Perez Segura, Martin E.
    Preidikman, Sergio
    [J]. MULTIBODY MECHATRONIC SYSTEMS (MUSME 2021), 2022, 110 : 143 - 150
  • [35] Nanowired three-dimensional cardiac patches
    Dvir, Tal
    Timko, Brian P.
    Brigham, Mark D.
    Naik, Shreesh R.
    Karajanagi, Sandeep S.
    Levy, Oren
    Jin, Hongwei
    Parker, Kevin K.
    Langer, Robert
    Kohane, Daniel S.
    [J]. NATURE NANOTECHNOLOGY, 2011, 6 (11) : 720 - 725
  • [36] Surface-based technique for warping three-dimensional images of the brain
    UCLA Sch of Medicine, Los Angeles, United States
    [J]. IEEE Trans Med Imaging, 4 (402-417):
  • [37] A surface-based technique for warping three-dimensional images of the brain
    Thompson, P
    Toga, AW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) : 402 - 417
  • [38] Three-dimensional echocardiography in cardiac surgery
    Hoda, M. R.
    Schwarz, T.
    Wolf, I.
    Mottl-Link, S.
    Meinzer, H. P.
    Karck, M.
    De Simone, R.
    [J]. CHIRURG, 2007, 78 (05): : 435 - 442
  • [39] Nanowired three-dimensional cardiac patches
    Tal Dvir
    Brian P. Timko
    Mark D. Brigham
    Shreesh R. Naik
    Sandeep S. Karajanagi
    Oren Levy
    Hongwei Jin
    Kevin K. Parker
    Robert Langer
    Daniel S. Kohane
    [J]. Nature Nanotechnology, 2011, 6 : 720 - 725
  • [40] Analysis of three-dimensional cardiac images
    Bravo, Antonio J.
    Vera, Miguel
    Madriz, Delia
    Contreras-Velasquez, Julio
    Huerfano, Yoleidy
    Chacon, Jose
    Wilches-Duran, Sandra
    Graterol-Rivas, Modesto
    Riano-Wilches, Daniela
    Rojas, Joselyn
    Bermudez, Valmore
    [J]. REVISTA LATINOAMERICANA DE HIPERTENSION, 2016, 11 (04): : 76 - 86