Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: a position statement

被引:124
|
作者
Anavekar, N [1 ]
Bais, R [1 ]
Carney, S [1 ]
Eris, J [1 ]
Gallagher, M [1 ]
Johnson, D [1 ]
Jones, G [1 ]
Sikaris, K [1 ]
Lonergan, M [1 ]
Ludlow, M [1 ]
Mackie, J [1 ]
Mathew, T [1 ]
May, S [1 ]
McBride, G [1 ]
Meerkin, M [1 ]
Peake, M [1 ]
Power, D [1 ]
Snelling, P [1 ]
Voss, D [1 ]
Walker, R [1 ]
机构
[1] Kidney Hlth Australia, Adelaide, SA 5006, Australia
关键词
D O I
10.5694/j.1326-5377.2005.tb06958.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The systematic staging of chronic kidney disease (CKD) by glomerular filtration measurement and proteinuria has allowed the development of rational and appropriate management plans. One of the barriers to early detection of CKD is the lack of a precise, reliable and consistent measure of kidney function. The most common measure of kidney function is currently serum creatinine concentration. It varies with age, sex, muscle mass and diet, and interlaboratory variation between measurements is as high as 20%. The reference interval for serum creatinine concentration includes up to 25% of people (particularly thin, elderly women) who have an estimated glomerular filtration rate (eGFR) that is significantly reduced (< 60mUmin/1.73m(2)). The recent publication of a validated formula (MDRD) to estimate GFR from age, sex, race and serum creatinine concentration, without any requirement for measures of body mass, allows pathology laboratories to "automatically" generate eGFR from data already acquired. Automatic laboratory reporting of eGFR calculated from serum creatinine measurements would help to identify asymptomatic kidney dysfunction at an earlier stage. eGFR correlates well with complications of CKD and an increased risk of adverse outcomes such as cardiovascular morbidity and mortality. We recommend that pathology laboratories automatically report eGFR each time a serum creatinine test is ordered in adults. As the accuracy of eGFR is suboptimal in patients with normal or near-normal renal function, we recommend that calculated eGFRs above 60mL/min/1.73m(2) be reported by laboratories as "> 60mL/min/1.73m(2)", rather than as a precise figure.
引用
收藏
页码:138 / +
页数:4
相关论文
共 50 条
  • [21] The impact of population-based identification of chronic kidney disease using estimated glomerular filtration rate (eGFR) reporting
    Richards, Nick
    Harris, Kevin
    Whitfield, Malcolm
    O'Donoghue, Donal
    Lewis, Robert
    Mansell, Martin
    Thomas, Stephen
    Townend, John
    Eames, Mick
    Marcelli, Daniele
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (02) : 556 - 561
  • [22] The Impact of Reporting Estimated Glomerular Filtration Rate
    Geara, Abdallah Sassine
    Azzi, Nadine
    Ghimire, Pratima
    Abdallah, Marie
    Siddiqui, Ayesha
    Bassil, Claude
    El-Sayegh, Suzanne
    [J]. RENAL FAILURE, 2011, 33 (05) : 486 - 488
  • [23] Automatic reporting of estimated glomerular filtration rate - Just what the doctor ordered
    Levey, Andrew S.
    Stevens, Lesley A.
    Hostetter, Thomas
    [J]. CLINICAL CHEMISTRY, 2006, 52 (12) : 2188 - 2193
  • [24] Determining prevalence of chronic kidney disease using estimated glomerular filtration rate - Reply
    Coresh, Josef
    Stevens, Lesley A.
    Levey, Andrew S.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (06): : 631 - 632
  • [25] Estimated Glomerular Filtration Rate Variability in Patients With Heart Failure and Chronic Kidney Disease
    Hein, Aaron M.
    Scialla, Julia J.
    Sun, Jie-lena
    Greene, Stephen J.
    Shaw, Linda K.
    Chiswell, Karen
    Pun, Patrick H.
    Mentz, Robert J.
    [J]. JOURNAL OF CARDIAC FAILURE, 2021, 27 (11) : 1175 - 1184
  • [26] Biological variation of measured and estimated glomerular filtration rate in patients with chronic kidney disease
    Rowe, Ceri
    Sitch, Alice J.
    Barratt, Jonathan
    Brettell, Elizabeth A.
    Cockwell, Paul
    Dalton, R. Neil
    Deeks, Jon J.
    Eaglestone, Gillian
    Pellatt-Higgins, Tracy
    Kalra, Philip A.
    Khunti, Kamlesh
    Loud, Fiona C.
    Morris, Frances S.
    Ottridge, Ryan S.
    Stevens, Paul E.
    Sharpe, Claire C.
    Sutton, Andrew J.
    Taal, Maarten W.
    Lamb, Edmund J.
    [J]. KIDNEY INTERNATIONAL, 2019, 96 (02) : 429 - 435
  • [27] The Effect of Percutaneous Nephrolithotomy on the Estimated Glomerular Filtration Rate in Patients with Chronic Kidney Disease
    Izol, Volkan
    Deger, Mutlu
    Akdogan, Nebil
    Ok, Fesih
    Bayazit, Yildirim
    Aridogan, Ibrahim Atilla
    [J]. JOURNAL OF ENDOUROLOGY, 2021, 35 (05) : 583 - 588
  • [28] Use of estimated glomerular filtration rate for drug dosing in the chronic kidney disease patient
    Hudson, Joanna Q.
    Nyman, Heather A.
    [J]. CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2011, 20 (05): : 482 - 491
  • [29] Impact of percutaneous nephrolithotomy on estimated glomerular filtration rate in patients with chronic kidney disease
    Bilen, Cenk Y.
    Inci, Kubilay
    Kocak, Burak
    Tan, Bekir
    Sarikaya, Saban
    Sahin, Ahmet
    [J]. JOURNAL OF ENDOUROLOGY, 2008, 22 (05) : 895 - 900
  • [30] Reporting of estimated glomerular filtration rate: Effect on physician recognition of chronic kidney disease and prescribing practices for elderly hospitalized patients
    Quartarolo, Jennifer M.
    Thoelke, Mark
    Schafers, Stephen J.
    [J]. JOURNAL OF HOSPITAL MEDICINE, 2007, 2 (02) : 74 - 78