Effective intensity-based 2D/3D rigid registration between fluoroscopic X-ray and CT

被引:0
|
作者
Knaan, D [1 ]
Joskowicz, L [1 ]
机构
[1] Hebrew Univ Jerusalem, Sch Comp Sci & Engn, IL-91904 Jerusalem, Israel
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present an effective intensity-based method for rigid registration of a patient preoperative CT to its intraoperative situation with a few fluoroscopic X-ray images obtained with a tracked C-arm. It improves upon existing methods and overcomes most of their intrinsic speed, robustness, and accuracy problems. For speed, we generate Digitally Reconstructed Radiographs on small, dynamically selected regions of interest from precomputed ray gray levels in expected viewing directions, and use a multiresolution hierarchy of fluoroscopic X-ray images. For robustness and accuracy, we use a two-step comparison measure: Normalized Cross Correlation followed by Variance Weighted Sum of Local Normalized Correlation. To avoid local minima, we use a genetic search method. Our experiments on simulated, in-vitro, and cadaver data show an overall mean Target Registration Error of 0.8mm (max=1.5mm), 95% of the time, computed in 20-100 seconds under realistic conditions.
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [41] Intensity-based 3D/3D image registration for prostate localization on CBCT images
    Kim, J.
    Hammoud, R.
    Li, S.
    Lord, B.
    Patel, S.
    Pradhan, D.
    Movsas, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2018 - 2018
  • [42] Intensity-based 2-D-3-D registration of cerebral angiograms
    Hipwell, JH
    Penney, GP
    McLaughlin, RA
    Rhode, K
    Summers, P
    Cox, TC
    Byrne, JV
    Noble, JA
    Hawkes, DJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1417 - 1426
  • [43] Unifying energy minimization and mutual information maximization for robust 2D/3D registration of x-ray and CT images
    Zheng, Guoyan
    PATTERN RECOGNITION, PROCEEDINGS, 2007, 4713 : 547 - 557
  • [44] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66
  • [45] Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney
    Antoine Leroy
    Pierre Mozer
    Yohan Payan
    Jocelyne Troccaz
    International Journal of Computer Assisted Radiology and Surgery, 2007, 2 : 31 - 41
  • [46] Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney
    Leroy, Antoine
    Mozer, Pierre
    Payan, Yohan
    Troccaz, Jocelyne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 (01) : 31 - 41
  • [47] 2D/3D Registration for X-ray Guided Bronchoscopy using Distance Map Classification
    Xu, Di
    Xu, Sheng
    Herzka, Daniel A.
    Yung, Rex C.
    Bergtholdt, Martin
    Gutierrez, Luis F.
    McVeigh, Elliot R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3715 - 3718
  • [48] Automatic multimodal 2D/3D breast image registration using biomechanical FEM models and intensity-based optimization
    Hopp, T.
    Dietzel, M.
    Baltzer, P. A.
    Kreisel, P.
    Kaiser, W. A.
    Gemmeke, H.
    Ruiter, N. V.
    MEDICAL IMAGE ANALYSIS, 2013, 17 (02) : 209 - 218
  • [49] Globally Learnable Point Set Registration Between 3D CT and Multi-view 2D X-ray Images of Hip Phantom
    Pan, Jin
    Min, Zhe
    Zhang, Ang
    Ma, Han
    Meng, Max Q. -H.
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (IEEE-ROBIO 2021), 2021, : 272 - 277
  • [50] An intensity-based approach to X-ray mammography - MRI registration
    Mertzanidou, Thomy
    Hipwell, John H.
    Tanner, Christine
    Hawkes, David J.
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623