Fluctuation of indoor temperature caused by insufficient cooling supply: Computer simulation and experimental study

被引:0
|
作者
Yang, Lei [1 ]
Wei, Jinghua
Wu, Gao [1 ]
机构
[1] Zhongyuan Univ Technol, Dept Energy & Environm, Zhengzhou 450007, Peoples R China
关键词
fluctuation of temperature; cooling load; CFD; subjective evaluation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy recovery ventilator (ERV) is generally installed in an air-conditioning system to recycle the cooling load of exhaust air. However, air conditioning systems with the single ERV can not meet with outdoor air load and indoor cooling load in summer,,which will cause fluctuation of indoor temperature. The goal of this study is to analyze such a fuctuating scenario of the indoor temperature. CFD and subjective evaluation are used in this study. The resuls of CFD confirm the improvement of the air-conditioning system before and after adding direct-expansion blast heater with heat pump in the primary air system and designing reasonable fresh air distribution. A computer room is chosen as the experimental case. The results demonstrate that the initial fluctuation of indoor air temperature has been reduced effectively before and after its rebuilding. New primary air system with ERV and direct-expansion blast heater with heat pump can improve indoor air quality and stabilize indoor temperature.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
  • [1] Experimental Study on the effects of layered air supply angle and air supply temperature on indoor environment
    Liu, Zeqin
    Yang, He
    Liu, Zhe
    Zuo, Zhenjun
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 213 - 218
  • [2] Computer simulation for the image intensity centroid fluctuation caused by laser speckle
    Li, Jitao
    Xiang, Liqun
    Xian, Tao
    Su, Xianyu
    Guangdian Gongcheng/Opto-Electronic Engineering, 1998, 25 (01): : 13 - 17
  • [3] Experimental Study on Indoor Air Temperature Distribution of Gravity Air-Conditioning for Cooling
    Li, Cuimin
    Zhao, Jianing
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT A, 2012, 17 : 961 - 967
  • [4] Experimental study on three-dimensional temperature fluctuation caused by coaxial-jet flows
    Lu, Daogang
    Cao, Qiong
    Lv, Jing
    Xiao, Yang
    NUCLEAR ENGINEERING AND DESIGN, 2012, 243 : 234 - 242
  • [5] Experimental study of surface temperature non-uniformity and fluctuation in dense controllable droplet trains cooling
    Li, Yuhang
    Xia, Yakang
    Qiu, Borong
    Li, Murun
    Li, Haiwang
    Gao, Xuan
    APPLIED THERMAL ENGINEERING, 2025, 261
  • [6] Passive cooling and natural ventilation by the windcatcher (Badgir): An experimental and simulation study of indoor air quality, thermal comfort and passive cooling power
    Nejat, Payam
    Ferwati, M. Salim
    Calautit, John
    Ghahramani, Ali
    Sheikhshahrokhdehkordi, Mohammadamin
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [7] Is Economic Fluctuation Inevitable?-A simulation study from a supply chain perspective
    Chen Ronghu
    PROCEEDINGS OF 2009 CONFERENCE ON SYSTEMS SCIENCE, MANAGEMENT SCIENCE & SYSTEM DYNAMICS, VOL 1, 2009, : 89 - 93
  • [8] Computer Simulation of Temperature Distribution during Cooling of the Thermally Insulated Room
    Charvatova, Hana
    Prochazka, Ales
    Zalesak, Martin
    ENERGIES, 2018, 11 (11)
  • [9] Topical cardiac cooling-computer simulation of myocardial temperature changes
    Trunk, P
    Gersak, B
    Trobec, R
    COMPUTERS IN BIOLOGY AND MEDICINE, 2003, 33 (03) : 203 - 214
  • [10] Experimental study on a novel split thermoelectric cooler of big temperature difference for combined cooling and heating supply
    Yang, Jinwen
    Liang, Wenxing
    Han, Jitian
    Wu, Ruoyun
    Su, Yanmei
    ENERGY CONVERSION AND MANAGEMENT, 2024, 317