Computer Simulation of Temperature Distribution during Cooling of the Thermally Insulated Room

被引:6
|
作者
Charvatova, Hana [1 ]
Prochazka, Ales [2 ,3 ]
Zalesak, Martin [1 ]
机构
[1] Tomas Bata Univ Zlin, Fac Appl Informat, Zlin 76005, Czech Republic
[2] Univ Chem & Technol Prague, Dept Comp & Control Engn, Prague 16628, Czech Republic
[3] Czech Tech Univ, Czech Inst Informat Robot & Cybernet, Prague 16636, Czech Republic
关键词
thermal stability of building; COMSOL Multiphysics; computer simulation; 3D model; determination of temperature decrease for cooling the room; signal processing; smart city; HEAT-TRANSFER; BUILDING-MATERIALS; MASS-TRANSFER; ENERGY; CITY; TOOL;
D O I
10.3390/en11113205
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper is devoted to modelling of temperature distribution and its time evolution in rooms with specific thermal insulation and heat transfer for different external conditions. The simulation results should help to design the room architecture and wall materials to reduce energy losses due to heating or cooling, and to increase the inside thermal comfort. For this purpose, a methodological procedure using real data processing in the COMSOL Multiphysics modelling environment and spatial visualization of temperature evolution is proposed. This paper describes a mathematical model for simulation of the temperature evolution inside a space with thermally insulated walls under selected outside conditions. Computer simulations are then used to assess the temperature distribution inside the room and the heat flow through the room walls. Results of the simulations are used for subsequent determination of the time needed for the desired decrease of air temperature inside the tested room during its cooling due to the low ambient temperature, which is related to the thermal stability of the building, specific heat capacity, and thickness of the thermal insulation. Under the studied conditions, the time to reach the temperature drops by 20 percent in a room with windows was from 1.4 to 1.8 times lower than that in the room without windows. The proposed methodology shows the flexibility of computer modelling in the design of insulated building systems. The mesh density testing was performed by comparing the air temperature evolution in the model of the selected mesh density and the model with its maximum value enabled by the size of computer memory. The maximum temperature deviation calculated for the mesh of the presented model was 0.57%.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Computer Application for Simulation of Temperature Distribution Inside the Room
    Charvatova, Hana
    Zalesak, Martin
    22ND INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, COMMUNICATIONS AND COMPUTERS (CSCC 2018), 2018, 210
  • [2] Temperature Distribution in Insulated Temperature-Controlled Container by Numerical Simulation
    Li, Bin
    Guo, Jiaming
    Xia, Jingjing
    Wei, Xinyu
    Shen, Hao
    Cao, Yongfeng
    Lu, Huazhong
    Lu, Enli
    ENERGIES, 2020, 13 (18)
  • [3] Numerical simulation of temperature distribution and cooling rate in ship profiles during water spray cooling
    SINTEF Materials Technology, Trondheim, Norway
    Mater Sci Forum, (385-392):
  • [4] Numerical simulation of temperature distribution and cooling rate in ship profiles during water spray cooling
    Olden, V
    Thaulow, C
    Hjerpetjonn, H
    Sorli, K
    Osen, V
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MICROALLOYING IN STEELS, 1998, 284-2 : 385 - 392
  • [5] The Effect of Distribution on Product Temperature Profile in Thermally Insulated Containers for Express Shipments
    Singh, Jay
    Jaggia, Sanjiv
    Saha, Koushik
    PACKAGING TECHNOLOGY AND SCIENCE, 2013, 26 (06) : 327 - 338
  • [6] The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated
    Rjibi, Amel
    Kooli, Sami
    Guizani, Amenaallah
    HEAT AND MASS TRANSFER, 2018, 54 (11) : 3427 - 3443
  • [7] The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated
    Amel Rjibi
    Sami Kooli
    Amenaallah Guizani
    Heat and Mass Transfer, 2018, 54 : 3427 - 3443
  • [8] The Distribution Model of Temperature in HVAC System of Computer Room
    Feng, Youling
    Ye, Yang
    Zhu, Yujie
    Huang, Sijie
    PROCEEDINGS OF THE 2013 ASIA-PACIFIC COMPUTATIONAL INTELLIGENCE AND INFORMATION TECHNOLOGY CONFERENCE, 2013, : 342 - 345
  • [9] Effective computer room cooling
    Seaton, I
    COMMUNICATIONS NEWS, 2003, 40 (08): : 32 - 32
  • [10] Temperature of a thermally insulated surface in a gas flow
    A. F. Gutsol
    Technical Physics, 1998, 43 : 469 - 470