Computer Simulation of Temperature Distribution during Cooling of the Thermally Insulated Room

被引:6
|
作者
Charvatova, Hana [1 ]
Prochazka, Ales [2 ,3 ]
Zalesak, Martin [1 ]
机构
[1] Tomas Bata Univ Zlin, Fac Appl Informat, Zlin 76005, Czech Republic
[2] Univ Chem & Technol Prague, Dept Comp & Control Engn, Prague 16628, Czech Republic
[3] Czech Tech Univ, Czech Inst Informat Robot & Cybernet, Prague 16636, Czech Republic
关键词
thermal stability of building; COMSOL Multiphysics; computer simulation; 3D model; determination of temperature decrease for cooling the room; signal processing; smart city; HEAT-TRANSFER; BUILDING-MATERIALS; MASS-TRANSFER; ENERGY; CITY; TOOL;
D O I
10.3390/en11113205
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper is devoted to modelling of temperature distribution and its time evolution in rooms with specific thermal insulation and heat transfer for different external conditions. The simulation results should help to design the room architecture and wall materials to reduce energy losses due to heating or cooling, and to increase the inside thermal comfort. For this purpose, a methodological procedure using real data processing in the COMSOL Multiphysics modelling environment and spatial visualization of temperature evolution is proposed. This paper describes a mathematical model for simulation of the temperature evolution inside a space with thermally insulated walls under selected outside conditions. Computer simulations are then used to assess the temperature distribution inside the room and the heat flow through the room walls. Results of the simulations are used for subsequent determination of the time needed for the desired decrease of air temperature inside the tested room during its cooling due to the low ambient temperature, which is related to the thermal stability of the building, specific heat capacity, and thickness of the thermal insulation. Under the studied conditions, the time to reach the temperature drops by 20 percent in a room with windows was from 1.4 to 1.8 times lower than that in the room without windows. The proposed methodology shows the flexibility of computer modelling in the design of insulated building systems. The mesh density testing was performed by comparing the air temperature evolution in the model of the selected mesh density and the model with its maximum value enabled by the size of computer memory. The maximum temperature deviation calculated for the mesh of the presented model was 0.57%.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] EVALUATION OF INDIRECT ADIABATIC COOLING FOR A COMPUTER ROOM
    Krajci, Igor
    Marko, Adrian
    ENGINEERING REVIEW, 2007, 27 (01) : 49 - 53
  • [32] COMPUTER-SIMULATION OF BRAIN COOLING DURING CARDIOPULMONARY BYPASS - COMMENT
    KERN, FH
    GREELEY, WJ
    ANNALS OF THORACIC SURGERY, 1994, 57 (05): : 1178 - 1179
  • [33] Computer simulation of transparently insulated buildings for energy evaluation
    Chattha, J.A.
    Jesch, L.F.
    International Journal of Ambient Energy, 2000, 21 (01) : 11 - 20
  • [34] The computer simulation of the temperature distribution on the surface of ceramic cutting tools
    Liu, YR
    Liu, JJ
    Zhu, BL
    Luo, ZB
    Miao, HZ
    WEAR, 1997, 210 (1-2) : 39 - 44
  • [35] The computer simulation of temperature distribution on the surface of ceramic cutting tools
    Liu, Yourong
    Liu, Jiajun
    Zhu, Baoliang
    Mocaxue Xuebao/Tribology, 1997, 17 (01): : 81 - 88
  • [36] Experimental Simulation of Thermally Induced Stresses during Cooling of Continuously Cast Steel Slabs
    Schoebel, Michael
    Grosseiber, Simon
    Ilie, Sergiu
    Requena, Guillermo
    STEEL RESEARCH INTERNATIONAL, 2016, 87 (10) : 1312 - 1322
  • [37] A Simulation Model to Calculate Temperature Distribution of an Air-conditioned Room
    Fang, Ping
    Liu, Tingzhang
    Liu, Kai
    Zhang, Yingqi
    Zhao, Jianfei
    2016 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS (IHMSC), VOL. 1, 2016, : 378 - 381
  • [38] COMPUTER-AIDED DETERMINATION OF THE TEMPERATURE DISTRIBUTION ON PRIMARY COOLING BEDS AND AT ROLLING WITH COOLING BETWEEN THE STANDS
    HENSEL, A
    WEHAGE, H
    NEUE HUTTE, 1988, 33 (02): : 55 - 58
  • [39] TRANSIENT TEMPERATURE DISTRIBUTION IN WHOLE SWEETPOTATO ROOTS DURING IMMERSION HEATING .2. COMPUTER SIMULATION
    WADSWORT.JI
    SPADARO, JJ
    FOOD TECHNOLOGY, 1970, 24 (08) : 913 - &
  • [40] STUDIES ON TEMPERATURE DISTRIBUTION OF MILK DURING COOLING AND FREEZING.
    Kumar, R.Rajendra
    Verma, R.D.
    Journal of the Institution of Engineers (India), Part ND: New Divisions, 1980, 61 : 10 - 12