Scale effect in the evaluation of the fire resistance of glazed partitions

被引:1
|
作者
Sedlak, Bartlomiej [1 ]
Sulik, Pawel [1 ]
Garbacz, Andrzej [2 ]
机构
[1] Bldg Res Inst ITB, Fire Res Dept, Warsaw, Poland
[2] Warsaw Univ Technol, Fac Civil Engn, Warsaw, Poland
来源
关键词
Fire safety; Fire resistance; Fire integrity; Insulation; Fire test; Glazed partitions; Scale effect; INSULATION;
D O I
10.1016/j.jobe.2022.104108
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire-resistance testing procedures for glazed partitions used in Europe determine the minimum dimensions of the test items (2.8 x 3.0 m, width x height in the furnace opening lumen). Tests on minimum-sized items enable the evaluation of the fire resistance of slightly larger components. Nonetheless, they do not address the real problem of using fire-resistant glazed partitions, whose heights significantly exceed the dimensions of partitions verified in tests. This study resulted in the development of a model based on testing minimum-sized items, enabling the fire resistance evaluation of aluminium glazed partitions that are much higher than the test items. A typical scale effect should be expected in this situation, resulting from the difference in the dimensions of the test sample and the actual glass partition. The model was developed based on the results of eight tests on glazed partitions. The tests performed showed that there is a relationship between the profile stiffness in a glazed partition's mullion and the mullion's deflection during a fire resistance test. Moreover, it was observed that if a low partition maintains its fire integrity and insulation, identical behaviour can be expected of higher partitions in specific conditions. These phenomena aimed to develop an algorithm that enables the evaluation of the maximum acceptable height of an aluminium glazed partition for which the fire resistance is maintained.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Fire resistance evaluation through synthetic fire tests and generative adversarial networks
    Ciftcioglu, Aybike Ozyuksel
    Naser, M. Z.
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2024, 18 (04) : 587 - 614
  • [42] Effect of Fire Induced Restraint on Fire Resistance of Reinforced Concrete Beams
    Kodur, Venkatesh K. R.
    Dwaikat, Monther B.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2010, 1 (02) : 73 - 88
  • [43] A SMALL-SCALE FLAME TEST FOR FIRE-RESISTANCE EVALUATION OF RUBBER CONVEYOR BELTS WITH FABRIC SKELETONS
    NAKAGAWA, Y
    FIRE AND MATERIALS, 1989, 14 (02) : 67 - 72
  • [44] A methodology for the fire resistance testing of structural components at reduced scale
    OConnor, DJ
    Morris, B
    Silcock, GWH
    JOURNAL OF TESTING AND EVALUATION, 1997, 25 (03) : 273 - 282
  • [45] Evaluation of large-scale marine fire protocols
    USCG Research and Development Center, Groton, CT 06340-6096, United States
    不详
    ASTM Spec Tech Publ, 1336 (150-162):
  • [46] Evaluation of large-scale marine fire protocols
    Hansen, RL
    Back, GG
    VERY LARGE-SCALE FIRES, 1998, 1336 : 150 - 162
  • [47] The origins of low-fire polychrome glazed pottery in China
    Chen, Yulai
    Wen, Rui
    Wang, Tianyi
    ANTIQUITY, 2020, 94 (377)
  • [48] The risks associated with falling parts of glazed facades in case of fire
    Sedlak, Bartlomiej
    Kinowski, Jacek
    Sulik, Pawel
    Kimbar, Grzegorz
    OPEN ENGINEERING, 2018, 8 (01): : 147 - 155
  • [49] EFFECT OF FIBRES ON FIRE RESISTANCE OF CONCRETE STRUCTURES
    Stefan, R.
    Prochazka, J.
    FIBRE CONCRETE 2009: TECHNOLOGY, DESIGN, APPLICATION, 2009, : 237 - 242
  • [50] EFFECT OF POLYPROPYLENE FIBERS ON CONCRETE FIRE RESISTANCE
    Shihada, Samir
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2011, 17 (02) : 259 - 264