Continuous wave ultrasonic Doppler tomography

被引:5
|
作者
Liang, Haidong-Dong [1 ,2 ]
Tsui, Chun Sing Louis [1 ]
Halliwell, Michael [1 ]
Wells, Peter N. T. [2 ]
机构
[1] Univ Hosp Bristol NHS Fdn Trust, Bristol Gen Hosp, Dept Med Phys & Bioengn, Bristol BS1 6SY, Avon, England
[2] Cardiff Univ, Sch Engn, Cardiff CF24 3AA, S Glam, Wales
基金
美国国家卫生研究院; 英国工程与自然科学研究理事会;
关键词
Doppler tomography; ultrasonic imaging; medical imaging; coherent processing; incoherent processing; MOTION;
D O I
10.1098/rsfs.2011.0018
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In continuous wave ultrasonic Doppler tomography (DT), the ultrasonic beam moves relative to the scanned object to acquire Doppler-shifted frequency spectra which correspond to cross-range projections of the scattering and reflecting structures within the object. The relative motion can be circular or linear. These data are then backprojected to reconstruct the two-dimensional image of the object cross section. By using coherent processing, the spatial resolution of ultrasonic DT is close to an order of magnitude better than that of traditional pulse-echo imaging at the same ultrasound frequency.
引用
收藏
页码:665 / 672
页数:8
相关论文
共 50 条
  • [21] DESIGN OF A CONTINUOUS-WAVE DOPPLER ULTRASONIC FLOWMETER FOR PERIVASCULAR APPLICATION: PART 1, PROBE DESIGN.
    Richardson, P.C.A.
    Stevens, A.L.
    Cowan, D.
    Calil, S.
    Roberts, V.C.
    Medical and Biological Engineering and Computing, 1987, 25 (06): : 661 - 666
  • [22] Doppler continuous wave scanning acoustic microscope
    Titov, SA
    Maev, RG
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 713 - 718
  • [23] RELIABILITY OF CONTINUOUS-WAVE DOPPLER PROBES
    LONG, JW
    STEVENS, R
    LICHTI, E
    SILVER, D
    JOURNAL OF VASCULAR SURGERY, 1987, 5 (04) : 558 - 565
  • [24] Double Envelope With Continuous Wave Doppler: Not an Artifact
    Cobey, Frederick C.
    Khoche, Swapnil
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (11) : 3223 - 3227
  • [25] VARICOCELES EXPLORATION BY DOPPLER CONTINUOUS WAVE ULTRASONOGRAPHY
    BATTINO, J
    BATTINO, A
    CONTRACEPTION FERTILITE SEXUALITE, 1982, 10 (03): : 173 - 176
  • [27] ACCURACY OF DETERMINATION OF CHANGES IN CARDIAC-OUTPUT BY TRANS-CUTANEOUS CONTINUOUS WAVE ULTRASONIC DOPPLER COMPUTER
    ROSE, J
    CHANDRARATNA, PAN
    MCKAY, C
    ELKAYAM, U
    NANNA, M
    NIMALASURIYA, A
    RAHIMTOOLA, SH
    CIRCULATION, 1983, 68 (04) : 367 - 367
  • [28] Assessment of portable continuous wave Doppler ultrasound (ultrasonic cardiac output monitor) for cardiac output measurements in neonates
    Meyer, Sascha
    Todd, David
    Shadboldt, Bruce
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2009, 45 (7-8) : 464 - 468
  • [29] BREAST EXAMINATIONS WITH CONTINUOUS WAVE AND COLOR DOPPLER
    MADJAR, H
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1992, 2 (03) : 215 - 220
  • [30] Ultrasonic tomography for reflection and transmission wave analysis
    Rymarczyk, Tomasz
    Golabek, Michat
    Cieplak, Tomasz
    Kania, Konrad
    Adamkiewicz, Przemyslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (03): : 170 - 173