Field-widened Michelson interferometer system as the spectroscopic filter of high-spectral-resolution lidar

被引:0
|
作者
Cheng, Zhongtao [1 ]
Liu, Dong [1 ]
Zhou, Yudi [1 ]
Yang, Yongying [1 ]
Zhang, Yupeng [1 ]
Luo, Jing [1 ]
Bai, Jian [1 ]
Liu, Chong [1 ]
Shen, Yibing [1 ]
机构
[1] Zhejiang Univ, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
关键词
aerosol remote sensing; high-spectral-resolution lidar; field-widened Michelson interferometer; frequency locking technique; spectroscopic filter; AEROSOL; DISCRIMINATION;
D O I
10.1117/12.2223715
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose and develop a field-widened Michelson interferometer (FWMI) system to act as a new type of spectroscopic filter in HSRL application. Due to the field widening characteristic, the FWMI can allow relatively large off-axis incident angle, and can be designed to any desirable wavelength. The theoretical foundations of the FWMI are introduced in this paper, and the developed prototype interferometer is described. It consists of a solid arm made of the glass H-ZF52 with the dimension of 37.876 mm, and an air gap with the length of 20.382 mm. These two interference arms are connected to a cube beam splitter to constitute a Michelson interferometer. Due to the matched dimensions and refractive indices of the two arms, the experimental testing results show that the OPD variation of the developed FWMI is about 0.04 lambda and the RMS is less than 0.008 lambda when the incident angle is as much as 1.5 degree (half angle). The cumulative wavefront distortion caused by the FWMI is less than 0.1 lambda PV value and 0.02 lambda RMS value. To lock the filtering frequency of the FWMI to the laser transmitter, a frequency locking system, which is actually an electro-optic feedback loop, is established. The setup and principle of this frequency locking system are also described in detail. Good locking accuracy of the FWMI about 27MHz is demonstrated through the frequency locking technique. All these results validate the feasibility of this developed FWMI system as a spectroscopic filter of an HSRL.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Influences analysis of the spectral filter transmission on the performance of high-spectral-resolution lidar
    Cheng, Zhongtao
    Liu, Dong
    Luo, Jing
    Yang, Yongying
    Wang, Zhifei
    Zhou, Yudi
    Huang, Hanlu
    Shen, Yibing
    Guangxue Xuebao/Acta Optica Sinica, 2014, 34 (08):
  • [22] Frequency locking of a field-widened Michelson interferometer based on optimal multi-harmonics heterodyning
    Cheng, Zhongtao
    Liu, Dong
    Zhou, Yudi
    Yang, Yongying
    Luo, Jing
    Zhang, Yupeng
    Shen, Yibing
    Liu, Chong
    Bai, Jian
    Wang, Kaiwei
    Su, Lin
    Yang, Liming
    OPTICS LETTERS, 2016, 41 (17) : 3916 - 3919
  • [23] Heterodyne high-spectral-resolution lidar
    Chouza, Fernando
    Witschas, Benjamin
    Reitebuch, Oliver
    APPLIED OPTICS, 2017, 56 (29) : 8121 - 8134
  • [24] DEMONSTRATION OF A HIGH-SPECTRAL-RESOLUTION LIDAR BASED ON AN IODINE ABSORPTION FILTER
    PIIRONEN, P
    ELORANTA, EW
    OPTICS LETTERS, 1994, 19 (03) : 234 - 236
  • [25] Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer
    Scola, Salvatore J.
    Osmundsen, James F.
    Murchison, Luke S.
    Davis, Warren T.
    Fody, Joshua M.
    Boyer, Charles M.
    Cook, Anthony L.
    Hostetler, Chris A.
    Seaman, Shane T.
    Miller, Ian J.
    Welch, Wayne C.
    Kosmer, Adam R.
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION XVII, 2014, 9193
  • [26] Polar cap mesosphere wind observations: comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer
    Fisher, GM
    Killeen, TL
    Wu, Q
    Reeves, JM
    Hays, PB
    Gault, WA
    Brown, S
    Shepherd, GG
    APPLIED OPTICS, 2000, 39 (24) : 4284 - 4291
  • [27] High-spectral-resolution lidar using an iodine absorption filter for atmospheric measurements
    Liu, ZY
    Matsui, I
    Sugimoto, N
    OPTICAL ENGINEERING, 1999, 38 (10) : 1661 - 1670
  • [28] Polar cap mesosphere wind observations: Comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer
    Fisher, Genene M.
    Killeen, Timothy L.
    Wu, Qian
    Reeves, J. Michael
    Hays, Paul B.
    Gault, William A.
    Brown, Stephen
    Shepherd, Gordon G.
    Applied Optics, 2000, 39 (24): : 4284 - 4291
  • [29] High-spectral-resolution lidar for ocean ecosystem studies
    Liu, Dong
    Zhou, Yudi
    Yang, Yongying
    Cheng, Zhongtao
    Luo, Jing
    Zhang, Yupeng
    Shen, Yibing
    Wang, Kaiwei
    Liu, Chong
    Bai, Jian
    LASER RADAR TECHNOLOGY AND APPLICATIONS XXI, 2016, 9832
  • [30] Calibration of a high spectral resolution lidar using a Michelson interferometer, with data examples from ORACLES
    Burton, S. P.
    Hostetler, C. A.
    Cook, A. L.
    Hair, J. W.
    Seaman, S. T.
    Scola, S.
    Harper, D. B.
    Smith, J. A.
    Fenn, M. A.
    Ferrare, R. A.
    Saide, P. E.
    Chemyakin, E. V.
    Mueller, D.
    APPLIED OPTICS, 2018, 57 (21) : 6061 - 6075