Controlling the mass bias introduced by anionic and organic matrices in silicon isotopic measurements by MC-ICP-MS

被引:70
|
作者
Hughes, Harold J. [1 ,2 ]
Delvigne, Camille [1 ,2 ]
Korntheuer, Michael [3 ]
de Jong, Jeroen [2 ]
Andre, Luc [1 ]
Cardinal, Damien [1 ]
机构
[1] Royal Museum Cent Africa, Dept Earth Sci, Tervuren, Belgium
[2] Univ Libre Bruxelles, Dept Earth & Environm Sci, Brussels, Belgium
[3] Vrije Univ Brussel, Dept Analyt & Environm Chem, Brussels, Belgium
关键词
SI;
D O I
10.1039/c1ja10110b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the most widely used sample preparation methods for Si isotopic analyses (delta Si-30 and delta Si-29) is based on cationic chromatography, which does not remove anions from samples. Although it was first thought that the presence of anions in natural concentrations does not distort the isotopic analyses, it has recently been shown that the presence of sulfate can induce a significant shift in isotopic ratio measurements above SO42-/Si ratios (wt) of 0.02. Here, we show that dissolved organic matter can also induce a major Si isotopic bias when analysing river waters. To overcome these non-spectral matrix effects we propose fast and reliable ways, tested on natural freshwater and rock digestion solutions. The sulfate matrix effect is solved by adding to both sample and bracketing standard sulfuric acid in large excess compared to the naturally occurring SO42-. The organic matrix is mineralized by the combined action of UV-C and ozone. We also provide the first delta Si-30 signature measurements of two common geostandards: SGR-1 (delta Si-30 = +0.03 parts per thousand) and FeR-1 (delta Si-30 = -0.20 parts per thousand).
引用
收藏
页码:1892 / 1896
页数:5
相关论文
共 50 条
  • [21] Iron isotopic analyses of geological reference materials on MC-ICP-MS with instrumental mass bias corrected by three independent methods
    Zhu C.
    Lu W.
    He Y.
    Ke S.
    Wu H.
    Zhang L.
    Acta Geochimica, 2018, 37 (5) : 691 - 700
  • [22] Sulfur-induced offsets in MC-ICP-MS silicon-isotope measurements
    van den Boorn, Sander H. J. M.
    Vroon, Pieter Z.
    van Bergen, Manfred J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (08) : 1111 - 1114
  • [23] U-Th Isotopic Measurements by MC-ICP-MS with Multi-Static Method
    Li C.-H.
    Huang M.-J.
    Liao Z.-B.
    Kong X.-G.
    Shao Q.-F.
    Journal of Chinese Mass Spectrometry Society, 2019, 40 (03) : 209 - 221
  • [24] Determination of the Isotopic Composition of an Enriched Lutetium Spike by MC-ICP-MS
    Lin, Ran
    Zong, Keqing
    Lin, Jie
    Yang, Ao
    Chen, Kang
    Hu, Zhaochu
    Liu, Yongsheng
    ATOMIC SPECTROSCOPY, 2022, 43 (05) : 396 - 402
  • [25] Barium isotopic analysis of geological reference materials by MC-ICP-MS
    Ma, Shunrong
    Han, Guilin
    Zhang, Qian
    Liu, Jinke
    Ding, Ziyang
    Zhao, Ye
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2025, 228
  • [26] Mass bias stabilization by Mg doping for Si stable isotope analysis by MC-ICP-MS
    Oelze, Marcus
    Schuessler, Jan A.
    von Blanckenburg, Friedhelm
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (10) : 2094 - 2100
  • [27] Precise determination of the isotopic composition of Sn using MC-ICP-MS
    Clayton, R
    Andersson, P
    Gale, NH
    Gillis, C
    Whitehouse, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1248 - 1256
  • [28] New developments in measuring silicon isotopes by MC-ICP-MS
    Alleman, L
    Cardinal, D
    Ziegler, K
    André, L
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A14 - A14
  • [29] Argide interference reduction for Fe isotopic analysis by MC-ICP-MS
    Aimoz, L.
    Barling, J.
    Deboudt, K.
    Flament, P.
    Weis, D.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A10 - A10
  • [30] Precise Determination of Stable Strontium Isotopic Compositions by MC-ICP-MS
    Xu, Juan
    Yang, Shouye
    Yang, Yueheng
    Liu, Yongsheng
    Xie, Xiaolei
    ATOMIC SPECTROSCOPY, 2020, 41 (02) : 64 - 73