Controlling the mass bias introduced by anionic and organic matrices in silicon isotopic measurements by MC-ICP-MS

被引:70
|
作者
Hughes, Harold J. [1 ,2 ]
Delvigne, Camille [1 ,2 ]
Korntheuer, Michael [3 ]
de Jong, Jeroen [2 ]
Andre, Luc [1 ]
Cardinal, Damien [1 ]
机构
[1] Royal Museum Cent Africa, Dept Earth Sci, Tervuren, Belgium
[2] Univ Libre Bruxelles, Dept Earth & Environm Sci, Brussels, Belgium
[3] Vrije Univ Brussel, Dept Analyt & Environm Chem, Brussels, Belgium
关键词
SI;
D O I
10.1039/c1ja10110b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the most widely used sample preparation methods for Si isotopic analyses (delta Si-30 and delta Si-29) is based on cationic chromatography, which does not remove anions from samples. Although it was first thought that the presence of anions in natural concentrations does not distort the isotopic analyses, it has recently been shown that the presence of sulfate can induce a significant shift in isotopic ratio measurements above SO42-/Si ratios (wt) of 0.02. Here, we show that dissolved organic matter can also induce a major Si isotopic bias when analysing river waters. To overcome these non-spectral matrix effects we propose fast and reliable ways, tested on natural freshwater and rock digestion solutions. The sulfate matrix effect is solved by adding to both sample and bracketing standard sulfuric acid in large excess compared to the naturally occurring SO42-. The organic matrix is mineralized by the combined action of UV-C and ozone. We also provide the first delta Si-30 signature measurements of two common geostandards: SGR-1 (delta Si-30 = +0.03 parts per thousand) and FeR-1 (delta Si-30 = -0.20 parts per thousand).
引用
收藏
页码:1892 / 1896
页数:5
相关论文
共 50 条
  • [1] Effective Correction of Mass Bias for Rhenium Measurements by MC-ICP-MS
    Poirier, Andre
    Doucelance, Regis
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 195 - 204
  • [2] High precision cadmium isotopic measurements by MC-ICP-MS
    Cloquet, C
    Carignan, J
    Libourel, G
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A144 - A144
  • [3] Oxide Formation and Instrumental Mass Bias in MC-ICP-MS: An Isotopic Case Study of Neodymium
    Freres, Evelyn
    Weis, Dominique
    Newman, Karla
    Amini, Marghaleray
    Gordon, Kathy
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2021, 45 (03) : 501 - 523
  • [4] In Situ Ti Isotopic Measurements by Laser Ablation MC-ICP-MS
    Chen, Hsin-Wei
    Lee, Typhoon
    Lee, Der-Chuen
    Iizuka, Yoshiyuki
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2009, 20 (05): : 703 - 712
  • [5] Measurements of lithium isotopic compositions in coal using MC-ICP-MS
    He, Mao-Yong
    Luo, Chong-guang
    Lu, Hai
    Jin, Zhang Dong
    Deng, Li
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1773 - 1778
  • [6] Measurements of mass-dependent Te isotopic variation by hydride generation MC-ICP-MS
    Wasserman, N. L.
    Johnson, T. M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (02) : 307 - 319
  • [7] Chromium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Ponter, Simon
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (07) : 1464 - 1471
  • [8] Cadmium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Ohlander, Bjorn
    Ingri, Johan
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1570 - 1584
  • [9] Mass independent bias in W isotopes in MC-ICP-MS instruments
    Shirai, Naoki
    Humayun, Munir
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (07) : 1414 - 1420
  • [10] Mass bias correction laws suitable for MC-ICP-MS measurement
    Galer, SJG
    Abouchami, W
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A542 - A542