Glycemic Control and Perinatal Outcomes of Pregnancies Complicated by Type 1 Diabetes: Influence of Continuous Subcutaneous Insulin Infusion and Lispro Insulin

被引:33
|
作者
Chico, Ana [1 ]
Saigi, Ignasi [1 ]
Garcia-Patterson, Apolonia [1 ]
Dolores Santos, M. [1 ]
Adelantado, Juan M. [2 ]
Ginovart, Gemma [3 ]
de Leiva, Alberto [1 ]
Corcoy, Rosa [1 ]
机构
[1] Hosp Santa Creu & Sant Pau, Dept Endocrinol & Nutr, Barcelona 08025, Spain
[2] Hosp Santa Creu & Sant Pau, Dept Obstet & Gynecol, Barcelona 08025, Spain
[3] Hosp Santa Creu & Sant Pau, Dept Pediat, Barcelona 08025, Spain
关键词
MULTIPLE DAILY INJECTIONS; REGULAR INSULIN; CONTROLLED-TRIALS; THERAPY; WOMEN; PUMP; METAANALYSIS; HYPOGLYCEMIA; NETHERLANDS; NATIONWIDE;
D O I
10.1089/dia.2010.0111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. Methods: Three hundred fifteen consecutive singleton pregnancies of T1DM women using the same insulin program since before pregnancy (196 MDI with NPH + RI, 16 MDI with NPH + LP, 44 CSII with RI, 59 CSII with LP) were studied. Variables of glycemic control assessed included glycated hemoglobin, mean blood glucose (MBG), and insulin doses in each trimester, diabetic ketoacidosis, and hypoglycemic comas. Variables of pregnancy outcome included miscarriage, preterm birth, large or small for gestational age (LGA or SGA, respectively) newborns, and perinatal mortality. Multiple linear regression and logistic regression analysis were used. Results: Groups differed in baseline and glycemic control but not in maternal or fetal outcomes. In multivariate analysis, LP was associated with higher second trimester MBG and lower rate of hypoglycemic coma, CSII with higher third trimester MBG, and CSII + LP with lower insulin requirements and lower rate of hypoglycemic coma. As to pregnancy outcomes, LP was associated with lower risk of preterm birth and higher risk of SGA, CSII with lower risk of SGA and higher risk of LGA and perinatal mortality, and CSII + LP with higher risk of miscarriage. Conclusions: Pregnant women with T1DM using LP and/or CSII had different characteristics. LP with or without CSII was independently associated with fewer hypoglycemic comas, whereas impact of LP/CSII on the fetus had a favorable or an unfavorable influence depending on the specific outcome.
引用
收藏
页码:937 / 945
页数:9
相关论文
共 50 条
  • [21] INSULIN LISPRO WITH CONTINUOUS SUBCUTANEOUS INSULIN INFUSION IS SAFE AND EFFECTIVE IN PATIENTS WITH TYPE 2 DIABETES: A RANDOMIZED CROSSOVER TRIAL OF INSULIN LISPRO VERSUS INSULIN ASPART
    Thrasher, James
    Bhargava, Anuj
    Rees, Tina M.
    Wang, Tao
    Guzman, Cristina B.
    Glass, Leonard C.
    ENDOCRINE PRACTICE, 2015, 21 (03) : 247 - 257
  • [22] Longer gestation period and better glycemic control with insulin lispro treated pregnancies in type 1 diabetes
    Garg, K
    Anil, S
    Gottlieb, P
    MacKenzie, T
    Jackson, W
    DIABETOLOGIA, 2001, 44 : A245 - A245
  • [23] Flash glucose monitoring and glycemic control in type 1 diabetes with subcutaneous insulin infusion
    Sara Lomelino Pinheiro
    Margarida Bastos
    Luísa Barros
    Miguel Melo
    Isabel Paiva
    Acta Diabetologica, 2022, 59 : 509 - 515
  • [24] Fear of Hypoglycemia in Type 1 Diabetes Managed by Continuous Subcutaneous Insulin Infusion: Is It Associated with Poor Glycemic Control?
    Nixon, Rodanthe
    Pickup, John C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (02) : 93 - 98
  • [25] Insulin Glulisine Compared to Insulin Aspart and to Insulin Lispro Administered by Continuous Subcutaneous Insulin Infusion in Patients with Type 1 Diabetes: A Randomized Controlled Trial
    van Bon, Arianne C.
    Bode, Bruce W.
    Sert-Langeron, Caroline
    DeVries, J. Hans
    Charpentier, Guillaume
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (06) : 607 - 614
  • [26] Insulin glulisine for continuous subcutaneous insulin infusion in pediatric type 1 diabetes
    Urakami, Tatsuhiko
    Mine, Yusuke
    Aoki, Masako
    Okuno, Misako
    Suzuki, Junichi
    PEDIATRICS INTERNATIONAL, 2017, 59 (05) : 647 - 649
  • [27] Glycemic Control and Insulin Dosing in Pregnancies Complicated by Type 2 Diabetes Mellitus
    Nadeau, Hugh C.
    Maxted, Marta E.
    Madhavan, Devika
    Pierce, Stephanie
    Feghali, Maisa N.
    Scifres, Christina M.
    DIABETES, 2019, 68
  • [28] Psychopathology and Continuous Subcutaneous Insulin Infusion in Type 1 Diabetes
    Rotella, Francesco
    Lamanna, Caterina
    Dicembrini, Ilaria
    Faravelli, Carlo
    Calasso, Caterina
    Mannucci, Edoardo
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [29] Efficacy and Safety of Continuous Subcutaneous Insulin Infusion Therapy in Pregnancy Complicated by Type 1 Diabetes
    Cyganek, Katarzyna
    Hebda-Szydlo, Alicja
    Katra, Barbara
    Klupa, Tomasz
    Kaim, Irena
    Reron, Alfred
    Malecki, Maciej T.
    DIABETES, 2009, 58 : A466 - A467
  • [30] Efficacy and safety of continuous subcutaneous insulin infusion therapy in pregnancy complicated by type 1 diabetes
    Cyganek, K.
    Hebda-Szydlo, A.
    Katra, B.
    Klupa, T.
    Kaim, I.
    Skupien, J.
    Reron, A.
    Sieradzki, J.
    Malecki, M. T.
    DIABETOLOGIA, 2009, 52 : S462 - S462