X-ray spectrum of CT system acquired by Compton spectroscopy using high resolution Schottky CdTe detector

被引:1
|
作者
Maeda, K [1 ]
Matsumoto, M [1 ]
机构
[1] Hiroshima Int Univ, Fac Hlth Sci, Dept Clin Radiol, Hiroshima 7240695, Japan
关键词
diagnostic x-ray spectrum; Compton spectroscopy; high resolution Schottky CdTe detector; CT system;
D O I
10.1117/12.593564
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, x-ray computed tomography (CT) systems were developed dramatically; e.g. a multi-detector-row CT or a four-dimensional CT, but it has been expressed anxiety that a patient dose is increased. Analysis of x-ray spectrum is important for quality assurance and quality control of radiographic systems to estimate a quality of an imaging system and to decrease a patient dose. The aim of this study is to measure the x-ray spectra of CT system under clinical conditions using a high resolution Schottky CdTe detector. When measuring diagnostic x-ray spectra, the long distance from the x-ray source to the detector is requested for reducing a number of photons detected per unit time to prevent pile-up of the detector. However, that is very difficult to set up the long source-to-detector distance in a gantry of a CT unit. For resolving this problem, the Compton spectroscopy is very suitable. Using this method, a number of photons detected per unit time can be reduced by detecting the scattered x-ray photons. If the 90 degrees scattered photons can be detected, the energy correction and reconstruction of spectra can be calculated easily by use of the Klein-Nishina formula. So we attempt to acquire the primary x-ray spectra in the gantry of the CT unit by using Compton spectroscopy under a clinical (tube-rotating) condition. Moreover, to estimate the variation of x-ray spectra owe to changing position in the gantry, we measured the x-ray spectra and exposure doses at various points in the gantry.
引用
收藏
页码:1229 / 1236
页数:8
相关论文
共 50 条
  • [1] Compton spectroscopy of clinical x-ray equipments by using a high-resolution Schottky CdTe detector
    Maeda, Koji
    Matsumoto, Masao
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1475 - +
  • [2] Compton-scattering measurement of diagnostic x-ray spectrum using high-resolution Schottky CdTe detector
    Maeda, K
    Matsumoto, M
    Taniguchi, A
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1542 - 1547
  • [3] Ultra-High Resolution X-Ray CT System with a CdTe Detector
    Yoshitake, Junpei
    Ogawa, Koichi
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3106 - 3110
  • [4] Performance of a new schottky CdTe detector for hard X-ray spectroscopy
    Takahashi, T
    Hirose, EH
    Matsumoto, C
    Takizawa, K
    Ohno, R
    Ozaki, T
    Mori, K
    Tomita, Y
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND APPLICATIONS, 1998, 3446 : 29 - 37
  • [5] Performance of a new Schottky CdTe detector for hard x-ray spectroscopy
    Inst of Space and Astronautical, Science, Kanagawa, Japan
    [J]. IEEE Trans Nucl Sci, 3 pt 1 (428-432):
  • [6] Performance of a new schottky CdTe detector for hard X-ray spectroscopy
    Matsumoto, C
    Takahashi, T
    Takizawa, K
    Ohno, R
    Ozaki, T
    Mori, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 428 - 432
  • [7] Performance of a new Schottky CdTe detector for hard X-ray spectroscopy
    Matsumoto, C
    Takahashi, T
    Takizawa, K
    Ohno, R
    Ozaki, T
    Mori, K
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 569 - 573
  • [8] A high-resolution CT system using intraoral x-ray detector
    Chen, SK
    Chen, CM
    [J]. CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 798 - 802
  • [9] High-resolution Compton spectroscopy using x-ray microcalorimeters
    Patel, U.
    Guruswamy, T.
    Krzysko, A. J.
    Charalambous, H.
    Gades, L.
    Wiaderek, K.
    Quaranta, O.
    Ren, Y.
    Yakovenko, A.
    Ruett, U.
    Miceli, A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11):
  • [10] High resolution X-ray spectroscopy using a GaAs pixel detector
    Owens, A
    Bavdaz, M
    Peacock, A
    Andersson, H
    Nenonen, S
    Krumrey, M
    Puig, A