A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments

被引:12
|
作者
Mantell, SC
Chanda, H
Bechtold, JE [2 ]
Kyle, RF
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
[2] Hennepin Cty Med Ctr, Orthopaed Biomech Lab, Midwest Orthopaed Res Fdn, Minneapolis Med Res Fdn, Minneapolis, MN 55404 USA
关键词
D O I
10.1115/1.2834760
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To isolate the primary variables influencing acetabular cup and interface stresses, we performed an evaluation of cup lending and clip support variables, using a Statistical Design of Experiments (SDOE) approach. We developed three-dimensional finite element (FEM) models of the pelvis and adjacent bone. Cup support variables included fixation mechanism (cemented or noncemented), amount of bone support, and presence of metal backing. Cup loading variables included head size and clip thickness, cup/head friction, and conformity between the clip and head. Interaction between and among variables was determined using SDOE techniques. Of the variables tested, conformity, head size, and backing emerged as significant influences on stresses. Since initially nonconforming surfaces would be expected to wear into conforming surfaces, conformity is not expected to be a clinically significant variable. This indicates that head size should be tightly toleranced during manufacturing, and that small changes in head size can have a disproportionate influence on the stress environment. In addition, attention should be paid to the use of nonmetal backed clips, in limiting cup/bone interface stresses. No combination of secondary variables could compensate for, or oven ide the effect of the primary variables. Based on the results using the SDOE approach, adaptive FEM models simulating the wear process may be able to limit their parameters to head size and cup backing.
引用
收藏
页码:667 / 675
页数:9
相关论文
共 50 条
  • [31] Statistical Design and Analysis of Biological Experiments
    Hothorn, Ludwig A.
    [J]. BIOMETRICAL JOURNAL, 2021, 63 (08) : 1747 - 1747
  • [32] Statistical Design and Analysis of Biological Experiments
    Trianto, Manap
    [J]. JOURNAL OF QUALITY TECHNOLOGY, 2024,
  • [33] Design of experiments and statistical process control using wavelets analysis
    Cohen, Achraf
    Tiplica, Teodor
    Kobi, Abdessamad
    [J]. CONTROL ENGINEERING PRACTICE, 2016, 49 : 129 - 138
  • [35] STUDY OF TOOL WEAR IN EDM USING STATISTICAL DESIGN OF EXPERIMENTS
    Agrawal, Shyam S.
    Agarwal, Sanjay
    [J]. IMECE2008: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 4: DESIGN AND MANUFACTURING, 2009, : 355 - 360
  • [36] Design of experiments - Statistical design of experiments using the example of a hard gold electrolyte
    Design of experiment - Statistische versuchsplanung am beispiel eines hardgold-elektrolyten
    [J]. Berger, Sascha, 1600, Eugen G. Leuze Verlag (105):
  • [37] Jumbo Bionic Trabecular Metal Acetabular Cups Improve Cup Stability During Acetabular Bone Defect Reconstruction: A Finite Element Analysis Study
    Xiao, Jianlin
    Xue, Haowen
    Qian, Zhihui
    Xu, Shenghao
    Shen, Xianyue
    Zhang, Zhuo
    Ren, Lei
    Ren, Luquan
    [J]. JOURNAL OF BIONIC ENGINEERING, 2023, 20 (06) : 2814 - 2825
  • [38] Jumbo Bionic Trabecular Metal Acetabular Cups Improve Cup Stability During Acetabular Bone Defect Reconstruction: A Finite Element Analysis Study
    Jianlin Xiao
    Haowen Xue
    Zhihui Qian
    Shenghao Xu
    Xianyue Shen
    Zhuo Zhang
    Lei Ren
    Luquan Ren
    [J]. Journal of Bionic Engineering, 2023, 20 : 2814 - 2825
  • [39] The Parametric Analysis of a Bonded Overlap Joint Resulting in Design Guidelines and a Representation for Finite Element Analysis
    Pearson, I. T.
    [J]. STRAIN, 2001, 37 (03) : 113 - 121
  • [40] Exhaust stack silencer design using finite element analysis
    Howard, CQ
    Cazzolato, BS
    Hansen, CH
    [J]. NOISE CONTROL ENGINEERING JOURNAL, 2000, 48 (04) : 113 - 120