Development of a novel unbalanced ammonia-water absorption-resorption heat pump cycle for space heating

被引:21
|
作者
Jia, Teng [1 ,2 ]
Dai, Yanjun [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] MOE, Engn Res Ctr Solar Power & Refrigerat, Beijing, Peoples R China
关键词
Absorption-resorption; Heat pump; Ammonia-water; Solar thermal; Space heating; REFRIGERATION CYCLE; SOLAR-ENERGY; SYSTEM; PERFORMANCE; DRIVEN; OPTIMIZATION; COLLECTORS; PROTOTYPE; RECOVERY; PART;
D O I
10.1016/j.energy.2018.07.128
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ammonia-water absorption-resorption heat pump (ARHP) is a promising technology for promoting efficient utilization of low-temperature thermal for space heating. This paper proposes a novel unbalanced ARHP cycle by replacing the condenser and evaporator in the conventional absorption heat pump (AHP) cycle with a high-pressure absorber and a low-pressure generator, respectively. The proposed cycle can work just depending on the concentration difference of ammonia-water solution under different pressure levels. A numerical model has been developed to investigate the feasible high-pressure/low-pressure (P-H/P-L) values to effect the thermodynamic cycle. The cycle's coefficient of performance (COP) under different P-H/P-L pair values and other given working conditions are studied. The maximum COP is 1.550 and the corresponding optimum P-H/P-L pair to effect the cycle is 1.40 MPa/0.38 MPa at a heat source temperature of 95 degrees C. When P-H/P-L pair value is 1.40/0.38 MPa, heat supply temperature of 44.5 degrees C and COP value of 1.331 can be obtained, which can basically meet the temperature demand of building floor heating. In addition, effects of different P-H/P-L pair values on solution circulation ratios and vapor discharge scopes of generators are discussed. It is concluded that the ideal P-H/P-L candidates yield large concentration difference between the inlet and outlet of generators and absorbers. Meanwhile, the solution circulation ratios of the two generators at ideal P-H/P-L pairs are acceptable values between 2.0 and 12.0. The cycle can work when the ambient temperature is above 7.5 degrees C and the driving heat source temperature is larger than 85 degrees C, which is potential in efficient utilization of commonly used stationary solar collectors for winter heating. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 265
页数:15
相关论文
共 50 条
  • [41] The advantage of using a distillation tower in an ammonia-water absorption cycle for refrigeration
    Wu, LC
    Wu, CC
    Chang, YI
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 2000, 31 (02): : 193 - 197
  • [42] Performance analysis of ammonia-water absorption/compression combined refrigeration cycle
    Bao, Shuaiyang
    Du, Kai
    Cai, Xingchen
    Niu, Xiaofeng
    Wu, Yunlong
    [J]. Journal of Southeast University (English Edition), 2014, 30 (01) : 60 - 67
  • [43] Thermodynamic and thermoeconomic analysis of a novel ammonia-water mixture combined cooling, heating, and power (CCHP) cycle
    Parikhani, Towhid
    Azariyan, Hossein
    Behrad, Reza
    Ghaebi, Hadi
    Jannatkhah, Javad
    [J]. RENEWABLE ENERGY, 2020, 145 (145) : 1158 - 1175
  • [44] Performance analysis and validation on transportation of heat energy over long distance by ammonia-water absorption cycle
    Ma, Q.
    Luo, L.
    Wang, R. Z.
    Xia, Z. Z.
    Lin, P.
    Souyri, B.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (10) : 839 - 847
  • [45] 1ST LAW THERMODYNAMIC EVALUATION AND SIMULATION OF AMMONIA-WATER ABSORPTION HEAT-PUMP SYSTEMS
    MUMAH, SN
    ADEFILA, SS
    ARINZE, EA
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (08) : 737 - 750
  • [46] Thermal performance estimation of ammonia-water plate bubble absorbers for compression/absorption hybrid heat pump application
    Jung, Chung Woo
    An, Seung Sun
    Kang, Yong Tae
    [J]. ENERGY, 2014, 75 : 371 - 378
  • [47] An ammonia-water absorption refrigerator with a large temperature lift for combined heating and cooling
    Berlitz, T
    Plank, H
    Ziegler, F
    Kahn, R
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (03): : 219 - 229
  • [48] Thermodynamic analysis and optimization of a balanced-type single-stage NH3-H2O absorption-resorption heat pump cycle for residential heating application
    Jia, Teng
    Dai, Enqian
    Dai, Yanjun
    [J]. ENERGY, 2019, 171 : 120 - 134
  • [49] Transient simulation of ammonia-water mixture desorption for absorption heat pumps
    Roeder, Alexander A.
    Goyal, Anurag
    Garimella, Srinivas
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 354 - 367
  • [50] Compact Diesel Engine Waste-Heat-Driven Ammonia-Water Absorption Heat Pump Modeling and Performance Maximization Strategies
    Keinath, Christopher M.
    Delahanty, Jared C.
    Garimella, Srinivas
    Garrabrant, Michael A.
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (06):