The application of response surfaces for optimization of SERRS detection in a micro-fluidic device

被引:0
|
作者
Greenway, GM [1 ]
Moore, DA [1 ]
Walmsley, AD [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU67 7RX, N Humberside, England
来源
关键词
surface enhanced resonance Raman spectrometry; optimization; response curves;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Surface enhanced Raman resonance spectrometry (SERRS) using the surfaces of flowing colloidal particles provides a highly sensitive detection method for microfluidic systems. The sensitivity and reproducibility of the systems critically depends on the flow rates of the dye, colloid and aggregating agent in the microfluidic system. Optimization of these parameters was achieved using experimental design response surfaces to minimize the number of experiments required by augmenting small and large designs into one response surface. Using experimental design a linear calibration graph was obtained for cresyl violet acetate down to the 2 x 10(-9)M level.
引用
收藏
页码:470 / 472
页数:3
相关论文
共 50 条
  • [41] Control of the surface properties of micro-fluidic devices for external power-free biochip application
    Kyung-Min Jang
    Yoo-Jin An
    Hyun Park
    Young-Gun Kim
    Sung Yun Yang
    Macromolecular Research, 2013, 21 : 343 - 345
  • [42] Electrical detection of biomolecules in a PDMS micro-fluidic channel using a MOSFET-type biosensor
    Shin, Jang-Kyoo
    Kim, Dong-Sun
    Lim, Geunbae
    Shoji, Shuichi
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING III, 2007, 6416
  • [43] Optimization of elstomeric micro-fluidic valve dimensions using non-linear finite element methods
    Khawaja, H. A.
    Raouf, I.
    Parvez, K.
    Scherer, A.
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2009, 3 (02) : 187 - 200
  • [45] Optimization of a paper-based fluidic device for nitrogen detection
    Luthardt, Jackie
    DeShano, Emily
    Cissell, Kyle
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [46] Process parameter effects on dimensional accuracy of a hot embossing process for polymer-based micro-fluidic device manufacturing
    G. Cheng
    M. Sahli
    J.-C. Gelin
    T. Barriere
    The International Journal of Advanced Manufacturing Technology, 2014, 75 : 225 - 235
  • [47] Multi-Objective Knowledge-Based Strategy for Process Parameter Optimization in Micro-Fluidic Chip Production
    Zavoianu, Alexandru-Ciprian
    Lughofer, Edwin
    Pollak, Robert
    Meyer-Heye, Pauline
    Eitzinger, Christian
    Radauer, Thomas
    2017 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (SSCI), 2017,
  • [48] Control performance improvement research of EWOD micro-fluidic actuating device using multi-physics simulation method
    Han, Aruem
    Lee, Nak-Kyu
    Park, Jeanho
    Song, Jung-Han
    Park, Sung-Jun
    Lee, Hye-Jin
    BIOELECTRONICS, BIOMEDICAL, AND BIOINSPIRED SYSTEMS V AND NANOTECHNOLOGY V, 2011, 8068
  • [49] Process parameter effects on dimensional accuracy of a hot embossing process for polymer-based micro-fluidic device manufacturing
    Cheng, G.
    Sahli, M.
    Gelin, J. -C.
    Barriere, T.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 75 (1-4): : 225 - 235
  • [50] A new length detection-micro fluidic device using an autocatalytic reaction
    Kato, Jun
    Kubota, Toshio
    Igarashi, Shukuro
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 67 - 71