Geometrical and Monte Carlo projectors in 3D PET reconstruction

被引:36
|
作者
Aguiar, Pablo [1 ]
Rafecas, Magdalena [2 ]
Enrique Ortuno, Juan [3 ]
Kontaxakis, George [3 ]
Santos, Andres [3 ]
Pavia, Javier [4 ]
Ros, Domenec [5 ]
机构
[1] Univ Santiago de Compostela, Dept Fis Particulas, Complexo Hosp Univ Santiago de Compostela, Fdn IDICHUS IDIS, Santiago De Compostela, Spain
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Univ Politecn Madrid, Dept Ingn Elect, E-28040 Madrid, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Serv Med Nucl, Barcelona, Spain
[5] Univ Barcelona, IDIBAPS, Fac Med, Unitat Biofis, E-08007 Barcelona, Spain
关键词
3D PET; iterative reconstruction; list-mode reconstruction; ray-tracing techniques; Monte Carlo simulation; system response matrix; ITERATIVE IMAGE-RECONSTRUCTION; SYSTEM MATRIX; SCATTER; SIMULATION; ALGORITHM; IMPLEMENTATION; MODEL; EM;
D O I
10.1118/1.3501884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3501884]
引用
收藏
页码:5691 / 5702
页数:12
相关论文
共 50 条
  • [21] 3D quantitative photoacoustic image reconstruction using Monte Carlo method and linearization
    Okawa, Shinpei
    Hirasawa, Takeshi
    Tsujita, Kazuhiro
    Kushibiki, Toshihiro
    Ishihara, Miya
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [22] The noninvasive reconstruction of 3D temperature field in a biological body with Monte Carlo method
    Li, Kai-Yang
    Dong, Yong-Gang
    Chen, Cheng
    Zhang, Shao-Ping
    NEUROCOMPUTING, 2008, 72 (1-3) : 128 - 133
  • [23] Fully 3D PET Iterative Reconstruction Using Distance-Driven Projectors and Native Scanner Geometry
    Manjeshwar, Ravindra M.
    Ross, Steven G.
    Iatrou, Maria
    Deller, Timothy W.
    Stearns, Charles W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2804 - 2807
  • [24] Data rebinning and reconstruction in 3-D PET/CT oncological studies: A Monte Carlo evaluation
    Rizzo, G
    Castiglioni, I
    Russo, G
    Gilardi, MC
    Panzacchi, A
    Fazio, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 139 - 146
  • [25] A Monte-Carlo simulation study on coarse septa for scatter correction in 3D PET
    Hasegawa, T
    Tanaka, E
    Yamashita, T
    Watanabe, M
    Yamaya, T
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2110 - 2114
  • [26] Influences of 3D PET scanner components on increased scatter evaluated by a Monte Carlo simulation
    Hirano, Yoshiyuki
    Koshino, Kazuhiro
    Iida, Hidehiro
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 4017 - 4030
  • [27] Multiview Projectors/Cameras System for 3D Reconstruction of Dynamic Scenes
    Furukawa, Ryo
    Sagawa, Ryusuke
    Delaunoy, Amael
    Kawasaki, Hiroshi
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCV WORKSHOPS), 2011,
  • [28] Photon Propagation Correction in 3D Photoacoustic Image Reconstruction using Monte Carlo Simulation
    Cheong, Yaw Jye
    Stantz, Keith M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [29] Effect of noise and modeling errors on the reliability of fully 3D Monte Carlo reconstruction in SPECT
    Lazaro, D
    El Bitar, Z
    Breton, V
    Buvat, I
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2534 - 2537
  • [30] 3D geometrical segmentation and reconstruction of anatomical structures
    Bueno, G
    Flores, C
    Martinez, A
    Cosias, P
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 43 - 52